Dergiler / MN Kardiyoloji / 2001 / Cilt: 8 - Sayı: 4

Preoperatif mitral-aortik anulusun transtorasik ekokardiografi ile ölçülmesinin kapak replasmanına katkısının değerlendirilmesi

Value of preoperative prediction of aortic and mitral annulus with transthoracic echocardiography in valvular surgery

Sayfa
298–301
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Transtorasik ekokardiografi ile preoperatif anulus çap değerlendirmesinin pratik değeri olmadığı sonucuna varıldı

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:"Bu çalışmada preoperatif mitral ve aortik anulus transtorasik ekokardiografik (TTE) ölçümlerinin kapak replasmanı sırasında cerrahi değeri ve hasta kapak uyumsuzluğu araştırıldı.
📊
Temel Bulgular & Veri:Romatizmal kalp kapak hastalığı nedeniyle replasman planlanan prospektif 40 hasta çalışmaya alındı.
💡
Sonuç & Katkı:Transtorasik ekokardiografi ile preoperatif anulus çap değerlendirmesinin pratik değeri olmadığı sonucuna varıldı
🔬Tür:Araştırma Makalesi
📍Kapsam:40 hasta
⚙️Değişkenler:Kalp kapağı protezi implantasyonu · Kalp kapağı hastalıkları · İleriye dönük çalışma

Özet

"Bu çalışmada preoperatif mitral ve aortik anulus transtorasik ekokardiografik (TTE) ölçümlerinin kapak replasmanı sırasında cerrahi değeri ve hasta kapak uyumsuzluğu araştırıldı. Romatizmal kalp kapak hastalığı nedeniyle replasman planlanan prospektif 40 hasta çalışmaya alındı. Hastaların 22'si kadın 18'i erkek ortalama yaşları 41.11 ± 5.84 di. Hastaların 9'una AVR ve MVR, 17'una MVR, 14'ine AVR yapıldı. Preoperatif mitral ve aortik anulus çapı, sol ventrikül volüm ve çapları ölçüldü . Operatif olarak implante edilen mitral ve aort kapak numaraları kaydedildi. Postoperatif sol ventrikül çapları ve volümleri tekrar değerlendirildi. Ekokardiografik olarak ve operatif ölçülen mitral anulus çapları değerlendirildiğinde r=0,306 t=0.188 olarak saptandı ve anlamlı fark bulunamadı. Aynı şekilde ekokardiografik ve operatif aortik çaplarda r=0,252, t=0.197 olarak saptandı, iki grup arasında anlamlı fark bulunamadı. Transtorasik ekokardiografi ile preoperatif anulus çap değerlendirmesinin pratik değeri olmadığı sonucuna varıldı

Abstract

In this study, value of preoperative prediction of aortic and mitral annulus with transthoracic echocardiography in valvular surgery and valve-patient mismatch were searched. 40 (22 female, 18 male) patients with a mean age of 41.11 ± 5.84 scheduled for surgery for rheumatic heart valve disease were included in the study. AVR and MVR were performed in 9 patients, MVR to 17 patients, AVR in 14 patients. Preoperative mitral and aortic annulus diameter, left ventricle volume and diameters were measured. Operative implant sizes were recorded and postoperative left ventricle volume and diameters were remeasured. As mitral annulus size was recorded preoperatively by echocardiography and intraoperative real sizes were analyzed, r=0.306 and t=0.188 were found. There was no significant difference. Aortic size analysis revealed r=0,252, t=0.197, but the difference was not significant. It is concluded that preoperative annulus size measurements by transthoracic echocardiography has no practical value.

🔖

Bu Makaleye Atıf Yap

ÖZEREN, M., TOPHANELİOĞLU, T., DOLGUN, A., CEMRİ, Ö., DOĞAN, S. (2001). Preoperatif mitral-aortik anulusun transtorasik ekokardiografi ile ölçülmesinin kapak replasmanına katkısının değerlendirilmesi. MN Kardiyoloji, Cilt: 8 - Sayı: 4, 298–301. https://ajindex.com/articles/298058

Kaynakça (5)

  1. Izzat BM, Kadir I, Reeves B, Wilde P, Bryan A, Angelini G. Patient Prosthesis Mismatch is negligible with modern small-size aortic valve prosthesis Ann Thorac Surg 1999; 68:1657-60. Rahimtoola SH. Valve prosthesis-patient mismatch: an update. J Heart Valve Dis 1998; 7:207-210.
  2. Yazdanbakhsh AP, Brink R, Dekker E, Mol B. Small valve area index: its influence on early mortality after mitral valve replacement, Eurpean Journal of Cardio-thoracic Surg 2000; 17:222-227.
  3. Dumesnil JG, Honos GN, Lemieux M, Beauchemin J. Validation and application of indexed aortic prosthetic valve areas calculated by Doppler echocardiography. J Am Coll Cardiol 1990; 16:637-43. Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation 1978; 58:20-24.
  4. Rahimtoola SH, Murphy E. Valve prosthesis-patient mismatch. A long term sequela. Br heart Journal 1981; 45:331-335.
  5. Harpaz D, Shah P, Bezante G, Heo M, Stewart S, Hicks GL, Hall WJ.Meltzer RS. Transthoracic and transesophageal echocardiographic sizing of the aortic annulus to determine prosthesis size. Am J Cardiol 1993; 72:1411-7.