Dergiler / MN Oftalmoloji / 2014 / Cilt: 21 - Sayı: 2

Mikro-koaksiyel katarakt cerrahisinde hidroimplantasyon yöntemi ile katlanabilir göz içi lensi yerleştirilmesi sonuçlarımız

The results of ımplantation of foldable ıntraocular lenses through hydroimplantation technique during micro-coaxial cataract surgery

Sayfa
99–104
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Bulgular: Hidroimplantasyon grubunda takip süresince hiçbir gözde GİB artışı (>21 mm Hg) saptanmazken, sadece 5 gözde 1. gün +1 ön kamara reaksiyonu saptandı.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Mikro-koaksiyel katarakt cerrahisinde hidroimplantasyon yöntemiyle katlanabilir göz içi lensi (GİL) yerleştirilmesi sonuçlarını bildirmek.
📊
Temel Bulgular & Veri:Gereç ve Yöntem: Hidroimplantasyon yöntemiyle katlanabilir tek parça GİL yerleştirilen 42 hastanın 50 gözü (çalışma grubu) ile geleneksel yöntemle viskoelastik madde kullanarak GİL yerleştirilen 40 hastanın 50 gözü (kontrol grubu) prospektif olarak çalışma kapsamına alındı.
💡
Sonuç & Katkı:Bulgular: Hidroimplantasyon grubunda takip süresince hiçbir gözde GİB artışı (>21 mm Hg) saptanmazken, sadece 5 gözde 1. gün +1 ön kamara reaksiyonu saptandı.
🔬Tür:Araştırma Makalesi
📍Kapsam:42 hasta
⚙️Değişkenler:Alan Parametreleri

Özet

Amaç: Mikro-koaksiyel katarakt cerrahisinde hidroimplantasyon yöntemiyle katlanabilir göz içi lensi (GİL) yerleştirilmesi sonuçlarını bildirmek. Gereç ve Yöntem: Hidroimplantasyon yöntemiyle katlanabilir tek parça GİL yerleştirilen 42 hastanın 50 gözü (çalışma grubu) ile geleneksel yöntemle viskoelastik madde kullanarak GİL yerleştirilen 40 hastanın 50 gözü (kontrol grubu) prospektif olarak çalışma kapsamına alındı. En iyi düzeltilmiş görme keskinliği, santral kornea kalınlığı (SKK), göz içi basıncı (GİB), ön kamara reaksiyonu değerlendirildi. Ölçümler ameliyattan 3 gün önce ve ameliyat- tan sonra 1. gün, 3. gün, 1. hafta, 1. ve 2. aylarda yapıldı. Bulgular: Hidroimplantasyon grubunda takip süresince hiçbir gözde GİB artışı (>21 mm Hg) saptanmazken, sadece 5 gözde 1. gün +1 ön kamara reaksiyonu saptandı. Kontrol gru- bunda 1. gün kontrolde 13 gözde (%26) ön kamara reaksiyonu saptanırken, 9 gözde (%18) GİB yüksekti. Birinci haftada tüm gözlerde GİB normal olup ve ön kamara sakindi. Gruplar arasında ortalama düzeltilmiş GİB’te 1. gün haricindeki takiplerde anlamlı farklılık yoktu (1. gün; p=0,039). Görme keskinliğindeki değişim açısından gruplar arasında fark saptanmadı. Santral kornea kalınlığında artış kontrol grubunda 3. gün, 1. hafta ve 1. ayda hidroimplantas- yon grubuna göre daha yüksek bulundu. SKK’nın preoperatif değerlere dönmesi hidroimplan- tasyon grubunda 1. ayda, kontrol grubunda 2. ayda gerçekleşti. Sonuç: Hidroimplantasyon yöntemi katlanabilir göz içi lensi yerleştirilmesinde oldukça et- kili olup, cerrahi süre, cerrahi maliyet ve cerrahi sonrası komplikasyonlar açısından gelenek- sel yönteme göre oldukça avantajlıdır.

Abstract

Aim: To report the results of implantation of foldable intraocular lenses (IOLs) through hy- droimplantation technique during micro-coaxial cataract surgery. Material and Method: Fifty eyes of 42 patients (study group) in which foldable single- piece IOL was placed through hydroimplantation technique, and 50 eyes of 40 patients (con- trol group) in which IOL was placed through conventional method were included in the prospective study. Best-corrected visual acuity, central corneal thickness (CCT), intraocular pressure (IOP), anterior chamber reaction were evaluated. Measurements were performed 3 days before surgery and first day, third day, first week, first and second months after surgery. Results: While IOP elevation (>21 mmHg) was not detected in any of eyes, +1 anterior chamber reaction was seen only in 5 eyes. In control group, anterior chamber reaction was de- tected in 13 eyes (26%), IOP increased in 9 eyes (18%) at first day control. At first week con- trol, IOP was normal and anterior chamber was quite in all eyes. There was no significant dif- ference between groups during follow-up, except for first day (first day; p=0.039). There was no diffence between groups in terms of change in visual acuity. The increase in CCT was more in control group than hydroimplantation group at third day, first week, and first month. The re- covery of CCT to preoperative levels occured first month in hydroimplantation group and sec- ond month in control group. Conclusion: Hydroimplantation method is very effective in foldable IOL implantation, and is very advantageous in terms of surgical time, surgical cost, and postoperative complications, when compared conventional method.

🔖

Bu Makaleye Atıf Yap

ÖZYOL, E., ÖZYOL, P. Ş. (2014). Mikro-koaksiyel katarakt cerrahisinde hidroimplantasyon yöntemi ile katlanabilir göz içi lensi yerleştirilmesi sonuçlarımız. MN Oftalmoloji, Cilt: 21 - Sayı: 2, 99–104. https://ajindex.com/articles/297036

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Tak H. Hydroimplantation: foldable intraocular lens implanta- tion without an ophthalmic viscosurgical device. J Cataract Refract Surg 2010;36(3):377-9
  2. Dada VK, Sindhu N, Sachdev MS. Postoperative intraocular pressure changes with use of different viscoelastics. Ophthalmic Surg 1994;25:540-4
  3. Larson RS, Lindstrom RL, Skelnik DL. Viscoelastic agents. CLAO J 1989;15:151-60
  4. Leaming DV. Practice styles and preferences of ASCRS members-2003 survey. J Cataract Refract Surg 2004; 30(4):892-900 5. Tennen DG, Masket S. Short- and long-term effect of clear corneal incisions on intraocular pressure. J Cataract Refract Surg 1996;22:568-70
  5. Issa SA, Pachecco J, Mahmood U, Nolan J, Beatty S. A novel index for predicting intraocular pressure reduction following cataract surgery. Br J Ophthalmol 2005;89:543-6
  6. Shingleton BJ, Pasternack JJ, Hung JW, O’Donoghue MW. Three and five year changes in intraocular pressures after clear corneal phacoemulsification in open angle glaucoma patients, glaucoma suspects, and normal patients. J Glaucoma 2006;15:494-8
  7. Mathalone N, Hyams M, Neiman S, Buckman G, Hod Y, Geyer O. Long-term intraocular pressure after clear cornea phacoemulsification in glaucoma patients. J Cataract Refract Surg 2005;31:479-83
  8. Damji KF, Konstas AG, Liebmann JM, et al. Intraocular pres- sure following phacoemulsification in patients with and with- out exfoliation syndrome: a 2 year prospective study. Br J Ophthalmol 2006;90:1014-8
  9. Cimetta DJ, Cimetta AC. Intraocular pressure changes after clear corneal phacoemulsification in nonglaucomatous pseu- doexfoliation syndrome. Eur J Ophthalmol 2008;18:77-81
  10. Kim KS, Kim JM, Park KH, Choi CY, Chang HR. The effect of cataract surgery on diurnal intraocular pressure fluctation. J Glaucoma 2009;18:399-402
  11. Tong JT, Miller KM. Intraocular pressure change after suture- less phacoemulsification and foldable posterior chamber lens implantation. J Cataract Refract Surg 1998;24:256-62
  12. Schwenn O, Dick HB, Krummenauer F, Krist R, Pfeiffer N. Intraocular pressure after small incision cataract surgery: temporal sclerocorneal versus clear corneal incision. J Cataract Refract Surg 2001;27:421-5
  13. Pohjalainen T, Vesti E, Uusitalo RJ, Laatikainen L. Intraocular pressure after phacoemulsification and intraocular lens im- plantation in nonglaucomatous eyes with and without exfolia- tion. J Cataract Refract Surg 2001;27:426-31
  14. Kim KS, Kim JM, Park KH, Choi CY, Chang HR. The effect of cat