Dergiler / MN Oftalmoloji / 2007 / Cilt: 14 - Sayı: 2

Glokom olgularında kontrast duyarlılık ile görme alanı ve optik sinir başı stereometrik parametreleri arasındaki ilişkinin değerlendirilmesi

Evaluation of the correlation between contrast sensitivity and visual field and optic nerve head stereometric parameters in primary open angle glaucoma

Sayfa
100–104
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Bulgular: KD skorları 3cpd’de 1.420.21, 6cpd’de 1.610.26, 12cpd’de 1.190.33 ve 18cpd’de 0.780.31 olup 4 ayrı frekans grubu arasında fark vardı (p=0.002) ve hesaplanan skorlar test için normal kabul edilen değerlerden daha düşüktü.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Glokom hastalarında kontrast duyarlılık (KD) skorları ile görme alanı ve tarayıcı lazer oftalmoskop stereometrik parametreleri arasında ilişki olup olmadığını değerlendirmek.
📊
Temel Bulgular & Veri:Gereç ve Yöntem: Primer açık açılı glokom tanısıyla izlenen 32 hastanın 64 gözü değerlendirildi.
💡
Sonuç & Katkı:Bulgular: KD skorları 3cpd’de 1.420.21, 6cpd’de 1.610.26, 12cpd’de 1.190.33 ve 18cpd’de 0.780.31 olup 4 ayrı frekans grubu arasında fark vardı (p=0.002) ve hesaplanan skorlar test için normal kabul edilen değerlerden daha düşüktü.
🔬Tür:Araştırma Makalesi
📍Kapsam:32 hasta
⚙️Değişkenler:Görme alanları · Tanı teknikleri · oftalmolojik

Özet

Amaç: Glokom hastalarında kontrast duyarlılık (KD) skorları ile görme alanı ve tarayıcı lazer oftalmoskop stereometrik parametreleri arasında ilişki olup olmadığını değerlendirmek. Gereç ve Yöntem: Primer açık açılı glokom tanısıyla izlenen 32 hastanın 64 gözü değerlendirildi. Monoküler KD testi, 4 ayrı uzaysal frekansta (3,6,12 ve 18cpd) ölçüm imkanı sağlayan “CSV-1000E contrast sensitivity chart; Vector Vision, Greenville, OH” ile gerçekleştirildi. Humphrey otomatik perimetre ile en son çekilmiş santral 30-2 görme alanındaki ortalama deviasyon (MD) ve pattern standart deviasyon (PSD) değerleri kaydedildi. Tarayıcı lazer oftalmoskop (Heidelberg Retina Tomografisi, HRTII) ile optik sinir başı stereometrik parametreleri ölçüldü. Bulgular: KD skorları 3cpd’de 1.420.21, 6cpd’de 1.610.26, 12cpd’de 1.190.33 ve 18cpd’de 0.780.31 olup 4 ayrı frekans grubu arasında fark vardı (p=0.002) ve hesaplanan skorlar test için normal kabul edilen değerlerden daha düşüktü. Humphrey otomatik perimetre ile hesaplanan MD: -4.15.6 ve PSD: 3.82.9 idi, KD skorları ile korelasyon analizi yapıldığında, sadece 18cpd’de PSD ile korelasyon saptandı (p=0.047), diğerleriyle anlamlı bir ilişki saptanmadı (p>0.05). KD skorları ve stereometrik parametreler arasında korelasyon analizi yapıldığında; 3cpd’de çukurluk hacmi (p=0.039), çukurluk biçim ölçümü (p=0.040) ve rim alanı (p=0.043), 6cpd’de çizgi boyu yükseklik değişikliği (p=0.044), 12cpd’de çizgi boyu yükseklik değişikliği (p=0.047) ve sinir lifi tabakası kalınlığı (p=0.044), 18cpd’de çukurluk biçim ölçümü (p=0.048) ve rim alanı (p=0.030) ile korelasyon olduğu saptandı. Sonuç: Glokomlu gözlerde KD skorları test için kabul edilen normal değerlerden düşük bulunmuştur. Değişik uzaysal frekanslarda KD ile bazı görme alanı ve stereometrik parametreler arasında ilişki saptanmıştır. Bu bulgular KD testinin glokomun erken tanısında yardımcı olabileceğini düşündürmektedir.

Abstract

Purpose: To evaluate whether there is a correlation between contrast sensitivty (CS) scores, and visual field and scanning laser ophthalmoscope stereometric parameters in primary open angle glaucoma. Material and Methods: Sixty four eyes of 32 patients with primary open angle glaucoma were evaluated in this study. Monocular CS tests were performed with “CSV-1000E contrast sensitivity chart; Vector Vision, Greenville, OH” which measures the CS in 4 different spatial frequencies (3,6,12 and 18 cpd). The mean deviation (MD) and pattern standart deviation (PSD) parameters on the last visual field test with program 30-2 of the Humphrey automated perimetry were recorded. Optic nerve head stereometric parameters were measured with scanning laser ophthalmoscope (Heidelberg Retina Tomograph, HRT II). Results: CS scores were 1.420.21 for 3cpd, 1.610.26 for 6cpd, 1.190.33 for 12cpd and 0.780.31 for 18cpd and there was difference between these 4 different frequncies (p=0.002) and all these values were lower than the scores accepted as normal for the test. The MD and PSD measured with Humphrey automated perimetry were as follows respectively;-4.15.6 and 3.82.9. There was correlation between CS and PSD only for 18cpd (p=0.047), but there wasn’t any correlation for other frequencies (p>0.05). When analysis between CS and stereometric parameters were performed, it was seen that there was correlation with cup volume (p=0.039), cup shape measure (p=0.040) and rim area (p=0.043) for 3cpd, height variation contour (p=0.044) for 6cpd, height variation contour (p=0.047) and retinal nerve fiber thickness (p=0.044) for 12cpd and cup shape measure (p=0.048) and rim area (p=0.030) for 18cpd. Conclusion: CS scores in eyes with glaucoma were lower than the values accepted as normal for the test. There was correlation between CS of different spatial frequencies and some visual field and stereometric parameters. These findings suggest that CS test may help for the early diagnosis of glaucoma.

🔖

Bu Makaleye Atıf Yap

Takmaz, T., GENÇ, İ., KÜRKÇÜOĞLU, P., GÜRDAL, C., CAN, İ. (2007). Glokom olgularında kontrast duyarlılık ile görme alanı ve optik sinir başı stereometrik parametreleri arasındaki ilişkinin değerlendirilmesi. MN Oftalmoloji, Cilt: 14 - Sayı: 2, 100–104. https://ajindex.com/articles/295973

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Jonas JB, Königsreuther KA. Optic disc appearance in ocular hypertensive eyes. Am J Ophthalmol 1994; 117:732-40
  2. Quigley HA, Katz J, Derick RJ, ve ark. An evaluation of optic disc and nerve fiber layer examinations in monitoring prog ression of early glaucoma damage. Ophthalmology 1992; 99:19-28
  3. Wollstein G, Garway-Heath DF, Hitchings RA. Identification of early glaucoma cases with the scanning laser ophthalmos cope. Ophthalmology 1998; 105:1557-63
  4. Miglior S, Guareschi M, Albe E, ve ark. Detection of glauco matous visual field changes using the Moorfields regression analysis of the Heidelberg Retina Tomograph. Am J Ophthal mol 2003; 136:26-33
  5. Wilensky JT, Hawkins A. Comparison of contrast sensitivity, visual acuity and Humphrey visual field testing in patients with glaucoma. Tr Am Ophthalmol Soc 2001; 99:213-8
  6. Sample PA, Juang PSC, Weinreb RN. Isolating the effects of primary open-angle glaucoma on the contrast sensitivity func tion. Am J Ophthalmol 1991; 112:308-16
  7. Wood MW, Livie-Kitchin JE. Evaluation of the efficacy of con trast sensitivity measures for the detection of early primary open-angle glaucoma. Optom Vis Sci 1992; 63:175-81
  8. Stewart WC, Chauhan BC. Newer visual function test in the evaluation of glaucoma. Surv Ophthalmol 1995; 40:119-35
  9. Pomerance GN, Evans DW. Test-retest reliability of the CSV- 1000 contrast test and its relationship to glaucoma therapy. Invest Ophthalmol Vis Sci 1994; 35:3357-61
  10. Luksch AJRainer G,Koyuncu D,ve ark.Effect of nimodipine on ocular blooaflow and colour contrast sensitivity in patients with normal tension glaucoma. Br J Ophthalmol 2005;89:21-5
  11. Gandolfi SA, Cionino L, Vecchi M. Improvement of spatial con trast sensitivity threshold after surgical reduction of intraocu lar pressure in unilateral high-tension glaucoma. Acta Ophthalmol Scand Suppl 1997; 224:40
  12. Gandolfi SA, Cimino L, Sangermani C, ve ark. Improvement of spatial contrast sensitivity threshold after surgical reduction of intraocular pressure in unilateral high-tension glaucoma. In vest Ophthalmol Vis Sci 2005;46:197-201
  13. Evans DW, Hosking SL, Gherghel D, Bartlett JD. Contrast sensitivity improves after brimonidine therapy in primary open angle glaucoma: a case for neuroprotection. Br J Ophthalmol 2003; 87:1463-65
  14. Arden G, Jacobsen J. A simple grating test for contrast sensi tivity - glaucoma screening. Invest Ophthalmol Vis Sci 1978; 17:23-32 15. Ross J, Bron A, Reeves B, Emmerson P. Detection of o