Bulgular: Çalışmaya dahil edilen bebeklerin sağ göz için damlasız ortalama sferik değe- ri +0,77±0,77D, astigmatizma değeri -0,66±0,49D, sferik eşdeğeri +0,44±0,71D, sol göz için ortalama sferik değer +0,85±0,78D, astigmatizma değeri -0,70±0,51 D, sferik eşdeğeri +0,50±0,67 olarak saptandı.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Plusoptix CR03 fotorefraktometre cihazı ile ölçüm yapılan 1 yaşındaki bebeklerin refraksiyon değerlerini bildirmek.
📊
Temel Bulgular & Veri:Gereç ve Yöntem: Rutin göz muayenesi sırasında 254 bebeğin Plusoptix CR03 fotoref- raktometre ile alınan refraksiyon değerleri geriye dönük olan bu çalışmaya dahil edildi.
💡
Sonuç & Katkı:Bulgular: Çalışmaya dahil edilen bebeklerin sağ göz için damlasız ortalama sferik değe- ri +0,77±0,77D, astigmatizma değeri -0,66±0,49D, sferik eşdeğeri +0,44±0,71D, sol göz için ortalama sferik değer +0,85±0,78D, astigmatizma değeri -0,70±0,51 D, sferik eşdeğeri +0,50±0,67 olarak saptandı.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Amaç: Plusoptix CR03 fotorefraktometre cihazı ile ölçüm yapılan 1 yaşındaki bebeklerin refraksiyon değerlerini bildirmek. Gereç ve Yöntem: Rutin göz muayenesi sırasında 254 bebeğin Plusoptix CR03 fotoref- raktometre ile alınan refraksiyon değerleri geriye dönük olan bu çalışmaya dahil edildi. Olguların hepsinde her iki göz için damlasız ve damlalı sferik değerleri, astigmatizma değer- leri ve aksları, sferik eşdeğerleri değerlendirildi. Sikloplejik ölçüm için her hastaya %1 tropi- kamid damla damlatılıp 30 dakika beklenildikten sonra ölçüm alındı. Bulgular: Çalışmaya dahil edilen bebeklerin sağ göz için damlasız ortalama sferik değe- ri +0,77±0,77D, astigmatizma değeri -0,66±0,49D, sferik eşdeğeri +0,44±0,71D, sol göz için ortalama sferik değer +0,85±0,78D, astigmatizma değeri -0,70±0,51 D, sferik eşdeğeri +0,50±0,67 olarak saptandı. Sağ göz için sikloplejik ortalama sferik değer +2,01±1,05D, as- tigmatizma değeri -0.75±0.54D, sferik eşdeğeri +1.63±1.01D olarak saptandı. Sol göz için sikloplejik ortalama sferik değer +2,07±0,94D, astigmatizma değeri -0,77±0,57D, sferik eşdeğeri +1,68±0,90D olarak saptandı. Hastaların %8,7 (n=22)’sinde anizometropi saptandı. Sekiz hastaya (%3,1) damlalı muayene sonucuna göre uzak gözlüğü verildi. Sonuç: Refraktif kusurların erken tanınması göz sağlığı açısından önemlidir. Standart ölçümlerin uygulanabilirliğinin sınırlı olduğu küçük yaşlarda ambliyopi, anizometropi veya yük- sek refraktif kusurların saptanabilmesinde fotorefraksiyon iyi bir seçenektir.

Abstract

Aim: To report refraction values measured by plusoptix CR03 photorefractometry of 1 year-old infants. Material and Method: Refraction values, measured by plusoptix CR03, of 254 infants were included in this retrospective study. Spherical values, astigmatism values and spherical equiv- alent values were evaluated for both eyes of all infants before and after the cycloplegic drop. For the cycloplegic refraction tropicamide 1% was instilled and measurement was repeated 30 minutes later. Results: Without the cycloplegic drop the mean spherical value was +0.77±0.77D,astig- matism value was -0.66±0.49D,spherical equivalent was +0.44±0.71D for the right eye and mean spherical value was +0.85±0.78D, astigmatism value was -0.70±0.51D, spherical equiv- alent was +0.50±0.67D for the left eye of the infants included in the study. Cycloplegic mean spherical value was +2.01±1.05D,astigmatism value was -0.75±0.54D,spherical equivalent value was +1.63±1.01 D for the right eye. For the left eye cycloplegic mean spherical value was +2.07±0.94D,astigmatism value was -0.77±0.57D,spherical equivalent value was +1.68±0.90D. In 8.7% of the patients (n=22) anisometropia was identified. According to the cycloplegic examination spectacles were prescribed to 8 patients(%3.1). Conclusion: It is important to recognize refractive errors early. Photorefraction is a good alternative to recognize ambliyopia, anisometropia or high refractive errors in early childhood when the standart measurements have limited applicability

🔖

Bu Makaleye Atıf Yap

BAHADIR, A. E. K., COŞAR, C. B., ÜÇBAŞARAN, E. (2014). Plusoptix CR03 fotorefraktometre cihazı ile rutin göz muayenesi yapılan bir yaşındaki bebeklerin refraksiyon değerleri. MN Oftalmoloji, Cilt: 21 - Sayı: 1, 52–55. https://ajindex.com/articles/295620

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. Atkinson J, Braddick O, French J. Infant astigmatism: its dis- appearance with age. Vision Res 1980;20:891-3. 2.Mayer DL, Hansen RM, Moore BD, Kim S, Fulton AB. Cycloplegic refractions in healthy children aged 1 through 48 months. Arch Ophthalmol 2001;119:1625-8. 3.Atkinson J, Braddick O, Robier B, et al. Two infant vision screening programmes: Prediction and prevention of strabis- mus and amblyopia from photo-and videorefractive screen- ing. Eye 1996;10:189-98. 4.Ying GS, Kulp MT, Maguire M, Ciner E, Cyert L, Schmidt P; Vision in Preschoolers Study Group. Sensitivity of screening tests for detecting vision in preschoolers-targeted vision dis- orders when specificity is 94%. Optom Vis Sci 2005;82 (5):432-8. 5.Erdurmus M, Yagcı R, Karadag R, Durmus M. A comparison of photorefraction and retinoscopy in children. J AAPOS 2007;11:606-11. 6.Howland HC, Howland B. Photorefraction: A technique for study of refractive state at a distance. J Opt Soc Am 1974;64:240-9. 7.Küsbeci T, Yavaş G, Ermiş SS, Şanlı M, İnan ÜÜ, Öztürk F. Okulçağı Çocuklarında Powerrefraktör II (PlusoptixCR03) ile Saptanan Refraksiyon Kusurlarının Topcon Otorefraktometre ile Karşılaştırılması. T Klin J Ophthalmol 2007;16:251-6. 8.Abrahamsson M, Ohlsson J, Bjorndahl M, Abrahamsson H. Clinical evaluation of an eccentric infrared photorefractor: the PowerRefractor. Acta Ophthalmol Scand 2003;81:605-10. 9.Moghaddam AA, Kargozar A, Zarei-Ghanavati M, Najjaran M, Nozari V, Shakeri MT. Screening for amblyopia risk factors in pre-verbal children using the Plusoptix photoscreener: a cross-sectional population-based study. Br J Ophthalmol 2012;96:83-6. 10.Schimitzek T, Lagreze WA. Accuracy of a new photo-refrac- tometer in young and adult patients. Graefes Arch Clin Exp Ophthalmol 2005;243:637-45. 11.Arıcı C, Türk A, Keskin S, Ceylan OM, Mutlu FM, Altınsoy Hİ. Effect of cycloplegia on refractive errors measured with three different refractometers in school-age children. T J Med Sci 2012;42:657-65. 12.Schaeffel F, Mathis U, Brüggemann G. Noncycloplegic pho- torefractive screening in pre-school children with the “PowerRefractor” in a pediatric practice. Optom Vis Sci 2007; 84:630-9.