Dergiler / Mathematical and Computational Applications / 1996 / Cilt: 1 - Sayı: 1

An artificial neural network based preestimation filter for bad data detection identification and elimination in state estimation

Sayfa
159–164
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

In this paper, by using an artificial neural network (ANN), a bad data detection, identification and then elimination preestimation filter is outlined.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:State estimators are vitally important in energy control centers.
📊
Temel Bulgular & Veri:The measurements that come from control system are generally analysed by a state estimator.
💡
Sonuç & Katkı:In this paper, by using an artificial neural network (ANN), a bad data detection, identification and then elimination preestimation filter is outlined.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

State estimators are vitally important in energy control centers. The measurements that come from control system are generally analysed by a state estimator. Since there can always be bad measurements in the system, estimated value and the true value of the state estimator can be fer from each other. In this paper, by using an artificial neural network (ANN), a bad data detection, identification and then elimination preestimation filter is outlined.

🔖

Bu Makaleye Atıf Yap

UZUNOĞLU, M., KOCATEPE, C., YUMURTACI, R. (1996). An artificial neural network based preestimation filter for bad data detection identification and elimination in state estimation. Mathematical and Computational Applications, Cilt: 1 - Sayı: 1, 159–164. https://ajindex.com/articles/280272

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. F.C. Schweppe, 1. Wildes and Rom, Power system static state estimation, Parts I,II,III, IEEE Trans. Power Appar. Syst.,PAS-89 (1970) 120-135 [2] E. Handschin, F.C. Schweppe, Ji Kohlas and A. Fiechter, Bad data analysis for power system state estimation, IEEE Trans. Power Appar. Syst., PAS -94 (1975) 329-337 [3] HM. Merril and F.C. Schweppe, Bad data suppression in power system static estimation, IEEE Trans. Power Appar. Syst., PAS -90 (1975) 2718-2725 [4] A. Garcia, A. Monticelli and P. Abreu, Fast decoupled state estimation and bad data processing, IEEE Trans. Power Appar. Syst., PAS -98 (1979) 1645-1652 [5] W. W. Kotiuga and M. Vidyasagar, Bad data rejection properties of weighed least absolute value techniques applied to static state estimation,, IEEE Trans. Power Appar. Syst., PAS 101 (1982) 844-851 [6] Xiang Nian-de, Wang Shi-ying and Yu Er-keng, A new aproach for detection and identification of multiple bad data in power system state estimation, IEEE Trans. Power Appar. Syst., PAS 101 (1982) 454-461 [7] A. 1. Wood, B. F. Wollenberg, "Power Generation, Operation and Control", John Wiley and Sons (1984) [8] G. N. Korres and G. C. Contaxis, A reduced model for bad data processing in state estimation, IEEE Trans. Power Syst., 6 (2) (1991) 550-556 [9] S. Weerasooriya, M. A. EI-Sharkawi, M. Damborg and R. 1. Marks, Towards static-security assesment of a large-scale power system using neural networks, lEE Proc. e. 139 (1992) 64-70