Dergiler / Journal of Turkish Spinal Surgery / 2020 / Cilt: 31 - Sayı: 1

DISTAL MIGRATION OF THE RODS OF A CONSTRAINED POLYAXIAL PEDICLE SCREW SYSTEM

Sayfa
51–54
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

We report here three case incidents (in two patients) of lumbar degenerative disorders requiring spinal instrumentation that represented with caudal rod migration, all associated with one particular implant made.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Spinal instrumentation and surgical techniques have exponentially improved over the years, and today’s spinal surgeon is well equipped to rigidly fix the spine with minimum adverse effects.
📊
Temel Bulgular & Veri:Complications may emerge during or after the surgical operations.
💡
Sonuç & Katkı:We report here three case incidents (in two patients) of lumbar degenerative disorders requiring spinal instrumentation that represented with caudal rod migration, all associated with one particular implant made.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Spinal instrumentation and surgical techniques have exponentially improved over the years, and today’s spinal surgeon is well equipped to rigidly fix the spine with minimum adverse effects. Complications may emerge during or after the surgical operations. Infection, hematoma and neurological deficits are early noticed findings. Instrumentation problems i.e. screw and/or rod failures present in long-term after surgery. Caudal rod migration out of the spinal column is a rare entity. We report here three case incidents (in two patients) of lumbar degenerative disorders requiring spinal instrumentation that represented with caudal rod migration, all associated with one particular implant made.

🔖

Bu Makaleye Atıf Yap

AYHAN, S., MMOPELWA, T., ADHIKARI, P., NABI, V., ACAROĞLU, E. (2020). DISTAL MIGRATION OF THE RODS OF A CONSTRAINED POLYAXIAL PEDICLE SCREW SYSTEM. Journal of Turkish Spinal Surgery, Cilt: 31 - Sayı: 1, 51–54. https://ajindex.com/articles/271366

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Soroceanu A, Diebo BG, Burton D, Smith JS, Deviren V, Shaffrey C, et al; International Spine Study Group. Radiographical and Implant- Related Complications in Adult Spinal Deformity Surgery: Incidence, Patient Risk Factors, and Impact on Health-Related Quality of Life. Spine (Phila Pa 1976). 2015;40:1414-21
  2. Al-Binali AM, Sigalet D, Goldstein S, Al-Garni A, Robertson M. Acute lower gastrointestinal bleeding as a late complication of spinal instrumentation. J Pediatr Surg. 2001;36:498-500
  3. Dhatt S, Kumar S, Arora N, Dhillon M, Tripathy SK. Migration of anterior spinal rod from the dorsolumbar spine to the knee: an unusual complication of spinal instrumentation. Spine (Phila Pa 1976). 2010;35:E270-2
  4. Doulgeris J. Biomechanical comparison of titanium and cobalt chromium pedicle screw rods in an unstable cadaveric lumbar spine.: Mechanical Engineering, University of South Florida; 2013
  5. Wood KE, Fitch RD, Burton DC, Keiger CJ. Anterior scoliosis rod migration to the lower extremity. Spine J. 2009;9:e9-12
  6. Yablon IG, Cowan S, Mortara R. The migration of a Harrington rod after cervical fusion. Spine (Phila Pa 1976). 1993;18:356-8
  7. Bayri Y, Eksi MS, Dogrul R, Koc DY, Konya D. Migration of rod into retroperitoneal region: a case report and review of the literature. Korean J Spine. 2014;11:241-4
  8. Davne SH, Myers DL. Complications of lumbar spinal fusion with transpedicular instrumentation. Spine (Phila Pa 1976). 1992;17(6 Suppl):S184-9
  9. Leute PJ, Hammad A, Hoffmann I, Hoppe S, Klinger HM, Lakemeier S. Set screw fracture with cage dislocation after two-level transforaminal lumbar interbody fusion (TLIF): a case report. J Med Case Rep. 2015;9:22
  10. Agrawal A. Pedicle screw nut loosening: potentially avoidable causes of spine instrumentation failure. Asian Spine J. 2014;8:224-6
  11. Yamaguchi K, Konishi H, Hara S, Motomura Y. Biocompatibility studies of titanium-based alloy pedicle screw and rod system: histological aspects. Spine J. 2001;1:260-8
  12. Beguiristain J, del Rio J, Duart J, Barroso J, Silva A, Villas C. Corrosion and late infection causing delayed paraparesis after spinal instrumentation. Journal of pediatric orthopedics. J Pediatr Orthop B. 2006;15:320-3
  13. Lark RK, Caputo AM, Brown CR, Michael KW, Thacker JK, Richardson WJ. Distant Harrington rod migration 35 years after implantation. J Clin Neurosci. 2013;20:1452-3.