Dergiler / Bor Dergisi / 2016 / Cilt: 1 - Sayı: 1

Resin type and resin diameter effect on the adsorption of boron isotopes

Sayfa
40–44
Yayın Tarihi
2016-03-24
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The scope of this work is to investigate the effect of resin type and diameter from the point of Langmuir adsorption isotherm parameters of 10B and11B isotopes for chelating resin and weak base anion exchange resin.Keywords: Chromatography, Stationary Phase; Boron Isotopes; Langmuir Adsorption Isotherm Parameters

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:AbstractChromatography is a technique for molecular partition in which a fluid (mobile phase) carries the material containing the mixture to be separated (sample) past or through a solid or gel (stationary phase) contained in a vessel.
📊
Temel Bulgular & Veri:The stationary phase has characteristics that delay the passage of some molecular components of the sample more than the passage of others causing them to separate in the mobile phase emerging from the column.
💡
Sonuç & Katkı:The scope of this work is to investigate the effect of resin type and diameter from the point of Langmuir adsorption isotherm parameters of 10B and11B isotopes for chelating resin and weak base anion exchange resin.Keywords: Chromatography, Stationary Phase; Boron Isotopes; Langmuir Adsorption Isotherm Parameters
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

AbstractChromatography is a technique for molecular partition in which a fluid (mobile phase) carries the material containing the mixture to be separated (sample) past or through a solid or gel (stationary phase) contained in a vessel. The stationary phase has characteristics that delay the passage of some molecular components of the sample more than the passage of others causing them to separate in the mobile phase emerging from the column. The selection of stationary phase is one of the key factors for reaching an optimum separation in chromatographic applications. The scope of this work is to investigate the effect of resin type and diameter from the point of Langmuir adsorption isotherm parameters of 10B and11B isotopes for chelating resin and weak base anion exchange resin.Keywords: Chromatography, Stationary Phase; Boron Isotopes; Langmuir Adsorption Isotherm Parameters

🔖

Bu Makaleye Atıf Yap

SAĞLAM, G. (2016). Resin type and resin diameter effect on the adsorption of boron isotopes. Bor Dergisi, Cilt: 1 - Sayı: 1, 40–44. https://ajindex.com/articles/252167

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Sewell P., Clarke B., Chromatographic separations, New York, Wiley, 1988
  2. Jonsson J. A., Chromatographic theory and basic principles, New York, Marcel Dekker, 1987
  3. Braithwaite A., Smith FJ., Chromatographic methods. 5th ed. London Blackie, 1996
  4. Skoog D. A., West D. M., Holler F. J., Crouch S. R., Fundamentals of analytical chemistry. 8th ed. Thomson-Brooks Cole, Belmont, 2003
  5. Lim B. G., Ching C. B., Tan R. B. H., Determination of competitive aIsotherm of enantiomers on a dual-site adsorbent, 213-228, 1995
  6. Ravald L., Fornstedt T., Theoretical study of the accuracy of the elution by characteristic points method for Bi-Langmuir isotherms, 13th International Symposium on Preparative and Process ChromatographyJournal of Chromatography A, 908, 111–130, 26 January 2001
  7. Gentilini A., Migliorini C., Mazzotti M., Morbidelli M., Optimal operation of simulated moving-bed units for non-linear chromatographic separations: II. Bi-Langmuir Isotherm, Journal of Chromatography A, 805, 37–44, 1 May 1998
  8. Umpleby R. J., Baxter S. C., Chen Y., Shah R. N, Shimizu K. D., Characterization of molecularly imprinted polymers with the Langmuir−Freundlich isotherm, August 23, 2001 [9] Guiochon G., Felinger A., Shirazi D. G. G., Fundamentals of preparative and nonlinear chromatograph, Second Edition, 67-216, 2006
  9. Hashem N. N., Optimization of chiral separation of nadolol by simulated moving bed technology, pHD Thesis, The University of Western Ontario, December 2012. 11] Ching C. B., Ho C., Ruthven D. M., An improved adsorption process for the production of high-fructose syrup, AICHE Journal, 32, 1876–1880, 1986
  10. Choi Y. J., Han S. K., Chung S. T., Row K. H., Separation of racemic bupivacaine using simulated moving bed with mathematical model, Biotechnology and Bioprocess Engineering, 12, 625-633, 2007
  11. Asnin L., Kaczmarski K., Guiochon G., The adsorption of naproxen enantiomers on the chiral stationary phase whelk-O1 under reversed-phase conditions: The effect of buffer composition,Journal of Chromatography A, 1217, 7055-7064, 2010
  12. Sağlam G., Manufacture of simulated moving bed and annular chromatography systems: Assessment of BSA purification performance in annular chromatography, Master Thesis, Hacettepe University, Chemical Engineering Department, 2009
  13. Lorenz K., Maga J., Use of gas-liquid chromatography for quality evaluation of dry egg products, Journal of Food Science, 36 (6) 936–939, September 1971
  14. Kim J. I