Dergiler / European Oral Research / 2018 / Cilt: 52 - Sayı: 3

Effects of coloring procedures on shear bond strength between resin cement and colored zirconia

Sayfa
122–126
Yayın Tarihi
2018-09-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion Coloring zirconia did not affect the shear bond strength between zirconia and resin cement.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:DOI: 10.26650/eor.2018.440Purpose Debonding is expected as a frequent failure type in zirconia restorations.
📊
Temel Bulgular & Veri:Materials and methods There were 11 groups evaluated each containing 12 zirconia discs (15 mm x 12 mm x 1.6 mm).
💡
Sonuç & Katkı:Conclusion Coloring zirconia did not affect the shear bond strength between zirconia and resin cement.
🔬Tür:Araştırma Makalesi
📍Kapsam:2018 Verileri
⚙️Değişkenler:Shear bond strength · ceramic · coloring

Abstract

DOI: 10.26650/eor.2018.440Purpose Debonding is expected as a frequent failure type in zirconia restorations. Therefore the aim of the current study is to evaluate the shear bond strength between colored zirconia and resin cement. Materials and methods There were 11 groups evaluated each containing 12 zirconia discs (15 mm x 12 mm x 1.6 mm). Groups were colored with the colors A3, B1, C4, D2, and D4 of the VITA classical shade scale. Coloring procedure was carried out for either 3 second or 60 seconds for the study groups and the control group was left untreated. Specimens were then bonded to translucent resin cement having a thickness of 3 mm and width of 3 mm. The shear bond strength of the samples was measured in a universal testing machine with a crosshead speed of 1 mm per minute. Two-way analysis of variance and Tukey’s HSD test were used for pairwise comparisons. Also paired t-test was used for comparing groups with the same color but having different shading times. Results Any significant difference was not found between the shear bond strengths of samples depending on whether color or shading times. Among the groups, B1 (60 seconds of coloring) had the highest bond strength (10.05 MPa), while A3 (60 seconds of coloring) showed the lowest bond strength (6.72 MPa). However, these differences were not statistically significant. Conclusion Coloring zirconia did not affect the shear bond strength between zirconia and resin cement.

🔖

Bu Makaleye Atıf Yap

TUNCEL, İ., TURP, İ. (2018). Effects of coloring procedures on shear bond strength between resin cement and colored zirconia. European Oral Research, Cilt: 52 - Sayı: 3, 122–126. https://ajindex.com/articles/242999

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (17)

  1. Tinschert J, Zwez D, Marx R, Anusavice KJ. Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics. J Dent 2000; 28: 529-35
  2. Ardlin BI. Transformation-toughened zirconia for dental inlays, crowns and bridges: Chemical stability and effect of low-temperature aging on flexural strength and surface structure. Dent Mater 2002; 18: 590-5
  3. Ichikawa Y, Akagawa Y, Nikai H, Tsuru H. Tissue compatibility and stability of a new zirconia ceramic in vivo. J Prosthet Dent 1992; 68: 322-6
  4. Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials 1999; 20: 1-25
  5. Oilo M, Gjerdet NR, Tvinnereim HM. The firing procedure influences properties of a zirconia core ceramic. Dent Mater 2008; 24: 471-5
  6. Blatz MB, Oppes S, Chiche G, Holst S, Sadan A. Influence of cementation technique on fracture strength and leakage of alumina all-ceramic crowns after cyclic loading. Quintessence Int 2008; 39: 23-32
  7. Blatz MB, Sadan A, Kern M. Resin-ceramic bonding: A review of the literature. J Prosthet Dent 2003; 89: 268-74
  8. Atsu SS, Kilicarslan MA, Kucukesmen HC, Aka PS. Effect of zirconium-oxide ceramic surface treatments on the bond strength to adhesive resin. J Prosthet Dent 2006; 95: 430-6
  9. Derand T, Molin M, Kvam K. Bond strength of composite luting cement to zirconia ceramic surfaces. Dent Mater 2005; 21: 1158-62
  10. Palacios RP, Johnson GH, Phillips KM, Raigrodski AJ. Retention of zirconium oxide ceramic crowns with three types of cement. J Prosthet Dent 2006; 96: 104-14
  11. Chang J, Da Silva JD, Sakai M, Kristiansen J, Ishikawa-Nagai S. The optical effect of composite luting cement on all ceramic crowns. J Dent 2009; 37: 937-43
  12. Hill EE. Dental cements for definitive luting: A review and practical clinical considerations. Dent Clin North Am 2007; 51: 643-58
  13. Blatz MB, Sadan A, Maltezos C, Blatz U, Mercante D, Burgess JO. In vitro durability of the resin bond to feldspathic ceramics. Am J Dent 2004; 17: 169-72
  14. Kern M, Wegner SM. Bonding to zirconia ceramic: Adhesion methods and their durability. Dent Mater 1998; 14: 64-71
  15. Luthy H, Loeffel O, Hammerle CH. Effect of thermocycling on bond strength of luting cements to zirconia ceramic. Dent Mater 2006; 22: 195-200
  16. Lohbauer U, Zipperle M, Rischka K, Petschelt A, Muller FA. Hydroxylation of dental zirconia surfaces: Characterization and bonding potential. J Biomed Mater Res B Appl Biomater 2008; 87: 461-7
  17. Aboushelib MN, de Jager N, Kleverla