Dergiler / European Oral Research / 2018 / Cilt: 52 - Sayı: 2

Evaluation of Shore A hardness of maxillofacial silicones: the effect of dark storage and nanoparticles

Sayfa
99–104
Yayın Tarihi
2018-05-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Nanoparticle addition did not prevent hardening of the silicone elastomers with time.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:DOI: 10.26650/eor.2018.469Purpose Little has been reported how the addition of nanoparticles could affect the hardness of maxillofacial silicones.
📊
Temel Bulgular & Veri:The purpose of this study was to evaluate the effects of different types of nanoparticle additives and dark storage for 2-years on the Shore A hardness of two types of maxillofacial silicone elastomers.
💡
Sonuç & Katkı:Nanoparticle addition did not prevent hardening of the silicone elastomers with time.
🔬Tür:Araştırma Makalesi
📍Kapsam:2018 · 8 samples
⚙️Değişkenler:Aging · hardness · nanoparticles

Abstract

DOI: 10.26650/eor.2018.469Purpose Little has been reported how the addition of nanoparticles could affect the hardness of maxillofacial silicones. The purpose of this study was to evaluate the effects of different types of nanoparticle additives and dark storage for 2-years on the Shore A hardness of two types of maxillofacial silicone elastomers. Materials and Methods A-2000 and A-2006 Room Temperature Vulcanized (RTV) silicone elastomers were tested in this study. Silaned silica, fumed silica and titanium dioxide nanoparticles at concentrations of 10% by volume were used as fillers for the maxillofacial silicone elastomers. A total of 64 silicone specimens were fabricated, which includes 8 samples, 30 x 10 mm in size, from each silicone elastomers for each subgroup and also controls. After the initial Shore A hardness measurements, specimens were kept in dark conditions at room temperature for 2 years. The final measurements were then taken from the silicone specimens. All data were statistically analyzed. Results For both types of silicones, there was statistically significant differences among study groups (p<0.001). Fumed silica group showed the lowest hardness values in A-2000 after storage. However, no significant difference was observed between control and fumed silica groups. Control group showed the lowest hardness values in A-2006, while the highest hardness values were found in fumed silica group; there was no significant difference between silica and silane groups. Conclusion Shore A values of the specimens were within the acceptable range for the maxillofacial silicones after aging. Nanoparticle addition did not prevent hardening of the silicone elastomers with time.

🔖

Bu Makaleye Atıf Yap

ÇEVİK, P. (2018). Evaluation of Shore A hardness of maxillofacial silicones: the effect of dark storage and nanoparticles. European Oral Research, Cilt: 52 - Sayı: 2, 99–104. https://ajindex.com/articles/242995

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Cevik P, Eraslan O. Effects of the addition of titanium dioxide and silaned silica nanoparticles on the mechanical properties of maxillofacial silicones. J Prosthodont 2017; 26: 611-5. 2. dos Santos DM, Goiato MC, Sinhoreti MA, Moreno A, Dekon SF, Haddad MF, Pesqueira AA. Influence of natural weathering on colour stability of materials used for facial prosthesis. J Med Eng Technol 2012; 36: 267-70
  2. Akash RN, Guttal SS. Effect of incorporation of nano-oxides on color stability of maxillofacial silicone elastomer subjected to outdoor weathering. J Prosthodont 2015; 24: 569-75
  3. Akay C, Cevik P, Karakis D, Sevim H. In vitro cytotoxicity of maxillofacial silicone elastomers: Effect of nano-particles. J Prosthodont 2018; 27: 584-7
  4. Goiato MC, Pesqueira AA, Ramos da Silva C, Gennari Filho H, Micheline Dos Santos D. Patient satisfaction with maxillofacial prosthesis. Literature review. J Plast Reconstr Aesthet Surg 2009; 62: 175-80
  5. Hatamleh MM, Haylock C, Watson J, Watts DC. Maxillofacial prosthetic rehabilitation in the uk: A survey of maxillofacial prosthetists’ and technologists’ attitudes and opinions. Int J Oral Maxillofac Surg 2010; 39: 1186-92
  6. Han Y, Kiat-amnuay S, Powers JM, Zhao Y. Effect of nano-oxide concentration on the mechanical properties of a maxillofacial silicone elastomer. J Prosthet Dent 2008; 100: 465-73
  7. O’Brein WJ. Dental materials and their selection. Michigan: Quintessence Publishing, 2002, p.23
  8. Polyzois GL, Tarantili PA, Frangou MJ, Andreopoulos AG. Physical properties of a silicone prosthetic elastomer stored in simulated skin secretions. J Prosthet Dent 2000; 83: 572-7
  9. Dootz ER, Koran A, 3rd, Craig RG. Physical properties of three maxillofacial materials as a function of accelerated aging. J Prosthet Dent 1994; 71: 379-83
  10. Veres EM, Wolfaardt JF, Becker PJ. An evaluation of the surface characteristics of a facial prosthetic elastomer. Part I: Review of the literature on the surface characteristics of dental materials with maxillofacial prosthetic application. J Prosthet Dent 1990; 63: 193-7
  11. Polyzois GL. A study of the effect of crosslinking of hydroxyl terminated polydimethylsiloxane. Doctoral Dissertation, University of Wales, 1987
  12. Hatamleh MM, Polyzois GL, Silikas N, Watts DC. Effect of extraoral aging conditions on mechanical properties of maxillofacial silicone elastomer. J Prosthodont 2011; 20: 439-46
  13. Haug SP, Andres CJ, Munoz CA, Okamura M. Effects of environmental factors on maxi