Dergiler / GORM:Gynecology Obstetrics & Reproductive Medicine / 2020 / Cilt: 26 - Sayı: 3

The Impact of Delivery Type on Ventricular Performances of Healthy Neonates

Sayfa
220–226
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Cesarean delivery might be associated with the impairment in ventricular functions and, thus, a delay in the improvement and maturation of cardiac functions.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:OBJECTIVE: The present study aims to evaluate how the mode of delivery affects the alterations in myocar dial functions of healthy newborns within the first month of life.
📊
Temel Bulgular & Veri:STUDY DESIGN: This is a prospective review of 60 healthy term newborns whose cardiac functions were examined by M-mode and tissue Doppler echocardiography on the first day of their lives and sub-sequently at one month of age.
💡
Sonuç & Katkı:Cesarean delivery might be associated with the impairment in ventricular functions and, thus, a delay in the improvement and maturation of cardiac functions.
🔬Tür:Literatür & Derleme Çalışması
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

OBJECTIVE: The present study aims to evaluate how the mode of delivery affects the alterations in myocar dial functions of healthy newborns within the first month of life. STUDY DESIGN: This is a prospective review of 60 healthy term newborns whose cardiac functions were examined by M-mode and tissue Doppler echocardiography on the first day of their lives and sub-sequently at one month of age. RESULTS: At the first visit, the tricuspid annular plane systolic excursion was significantly higher in vagi-nally delivered newborns. Mitral and tricuspid E velocities and E/E’ ratio of the right ventricle and isovo-lumic relaxation time of right ventricle were also significantly higher in newborns delivered by cesarean section. Both of the groups had statistically similar M-mode and tissue Doppler echocardiography mea-surements at the time of the second visit. Only the increase in the tricuspid A velocity and myocardial performance index measured from septum between the first and second visits were significantly higher in the cesarean delivery group. When compared with the first visit, both isovolumic contraction time and isovolumic relaxation time were lower between the groups but myocardial performance index values were increased without significance at the second visit. CONCLUSION: Diastolic indices were significantly elevated in newborns delivered by cesarean section than neonates delivered by vaginal route. After one-month-long follow up, an increase was observed in diastolic ventricle functions of the vaginally delivered newborns but this increase was statistically in-significant. Cesarean delivery might be associated with the impairment in ventricular functions and, thus, a delay in the improvement and maturation of cardiac functions.

🔖

Bu Makaleye Atıf Yap

CİLSAL, E. (2020). The Impact of Delivery Type on Ventricular Performances of Healthy Neonates. GORM:Gynecology Obstetrics & Reproductive Medicine, Cilt: 26 - Sayı: 3, 220–226. https://ajindex.com/articles/227527

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Shiota T, Harada K, Takada G. Left ventricular systolic and diastolic function during early neonatal period using transthoracic echocardiography. Tohoku J Exp Med. 2002
  2. 197(3):151-8. doi: 10.1620/tjem.197.151 2. Agata Y, Hiraishi S, Misawa H, Han JH, Oguchi K, Horiguchi Y, et al. Hemodynamic adaptations at birth and neonates delivered vaginally and by Cesarean section. Biol Neonate. 1995
  3. 68(6):404-11. doi: 10.1159/000244 263 3. Stopfkuchen H. Changes of the cardiovascular system during the perinatal period. Eur J Pediatr. 1987
  4. 146(6):545- 9. doi: 10.1007/BF02467350 4. Mori K, Nakagawa R, Nii M, Edagawa T, Takehara Y, Inoue M, et al. Pulsed wave Doppler tissue echocardiography assessment of the long axis function of the right and left ventricles during the early neonatal period. Heart. 2004
  5. 90(2):175-80. doi: 10.1136/hrt.2002.008110 5. Kilsztajn S, de Souza Lopes E, Nunes do Carmo MS, de Andrade Reyes AM. [Apgar score associated with mode of delivery in Sao Paulo State, Brazil]. Cad Saude Publica. 2007
  6. 23(8):1886-92. doi: 10.1590/s0102-311x20070008 00015 6. Hiarada K, Orino T, Yasuoka K, Tamura M, Takada G. Tissue doppler imaging of left and right ventricles in normal children. Tohoku J Exp Med. 2000
  7. 191(1):21-9. doi:10.1620/tjem.191.21 7. Iwashima S, Sekii K, Ishikawa T, Itou H. Serial change in myocardial tissue Doppler imaging from fetus to neonate. Early Hum Dev. 2013
  8. 89(9):687-92. doi: 10.1016/j.earlhumdev.2013.04.017 8. Teichholz LE, Kreulen T, Herman MV, Gorlin R. Problems in echocardiographic volume determinations: echocardiographic-angiographic correlations in the presence of absence of asynergy. Am J Cardiol. 1976
  9. 37(1):7- 11. doi: 10.1016/0002-9149(76)90491-4 9. Cui W, Roberson DA. Left ventricular Tei index in children: comparison of tissue Doppler imaging, pulsed wave Doppler, and M-mode echocardiography normal values. J Am Soc Echocardiogr. 2006
  10. 19(12):1438-45. doi: 10. 1016/j.echo.2006.06.006 10. Hagnevik K, Irestedt L, Lundell B, Skoldefors E. Cardiac function and sympathoadrenal activity in the newborn after cesarean section under spinal and epidural anesthesia. Acta Anaesthesiol Scand. 1988
  11. 32(3):234-8. doi: 10.1111/j.1399-6576.1988.tb02721.x 11. Lundell BP, Hagnevik K, Faxelius G, Irestedt L, Lagercrantz H. Neonatal left ventricular performance after vaginal delivery and cesarean section under general or epidural anesthesia. Am J Perinatol. 1984
  12. 1(2):152-7. doi: 10.1055/s-2007-999992 12. Dyer RA, Els I, Farbas J, Torr GJ, Schoeman LK,