Dergiler / Eastern Journal of Medicine / 2021 / Cilt: 26 - Sayı: 2

Shaping Efficiency of WaveOne Gold and One Curve in Simulated J-Shaped Root Canals

Sayfa
242–247
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

While WOG group showed better centering ability at points 6-7, OC group exhibited better result at point 2.It was shown that WaveOne Gold and One Curve, which are single-file systems, could be used safely in J-shaped root canals with their glide path files.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:To evaluate the shaping efficiency of WaveOne Gold (WOG; Dentsply Sirona, Ballaigues, Switzerland)and One Curve (OC;Micro-Mega, Besancon, France) in J-shaped resin blocks.Forty simulated J-shaped root canals with 0.15 mm apical diameters and 2 %taper were divided into two groups (n=20) as follows; WOGG/WOG (25.07) group (glide path was created with WaveOne Gold Glider) and OneG/OC (25.06) (glide path was created with One G) group.
📊
Temel Bulgular & Veri:These parameters calculated with Image J Software Program based on 18 reference points with 1-mm intervals of the canal.
💡
Sonuç & Katkı:While WOG group showed better centering ability at points 6-7, OC group exhibited better result at point 2.It was shown that WaveOne Gold and One Curve, which are single-file systems, could be used safely in J-shaped root canals with their glide path files.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

To evaluate the shaping efficiency of WaveOne Gold (WOG; Dentsply Sirona, Ballaigues, Switzerland)and One Curve (OC;Micro-Mega, Besancon, France) in J-shaped resin blocks.Forty simulated J-shaped root canals with 0.15 mm apical diameters and 2 %taper were divided into two groups (n=20) as follows; WOGG/WOG (25.07) group (glide path was created with WaveOne Gold Glider) and OneG/OC (25.06) (glide path was created with One G) group. The pre-and post-instrumentation images were taken, and the transportation value (TV), centering ability (CA) and the total amount of resin removed (TRR) were calculated by using the superimposition of the images. These parameters calculated with Image J Software Program based on 18 reference points with 1-mm intervals of the canal. The data were analyzed with Kruskal-Wallis and than Dunn's multiple comparison tests. The significance level was set at P≤ .05.There was no statistically significant difference among OG/OC and WOG/WOGG groups' apical (points 1-3), middle (points 4-6), and coronal (points 7-9) sections in terms of both TV and TRR. The centering ability of the instruments was decreased in the curvature part (middle section) of the canals. While WOG group showed better centering ability at points 6-7, OC group exhibited better result at point 2.It was shown that WaveOne Gold and One Curve, which are single-file systems, could be used safely in J-shaped root canals with their glide path files.

🔖

Bu Makaleye Atıf Yap

ATEŞ, A. A., ARICAN, B. (2021). Shaping Efficiency of WaveOne Gold and One Curve in Simulated J-Shaped Root Canals. Eastern Journal of Medicine, Cilt: 26 - Sayı: 2, 242–247. https://ajindex.com/articles/222563

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. Yared G. Canal preparation using only one Ni-Ti rotary instrument: preliminary observations. Int Endod J 2008; 41: 339-344. 2.Letters S, Smith AJ, McHugh S, Bagg J. A study of visual and blood contamination on reprocessed endodontic files from general dental practice. Br Dent J 2005; 199: 522-525 3.Webber, J. Shaping canals with confidence: WaveOne GOLD single-file reciprocating system.Roots2015; 1: 34-40. 4.Bürklein S, Schäfer E. Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems. Journal of endodontics 2012; 38:850-852. 5.Staffoli S, Grande NM, Plotino G, et al. Influence of environmental temperature, heat-treatment and design on the cyclic fatigue resistance of three generations of a single-file nickel–titanium rotary instrument. Odontol 2019; 107: 301-307. 6.Micro Mega. The One Curve Brochure. Availabla at: https://micro-mega.com/wp-content/uploads/2018/03/60301824-D_Brochure-One-Curve-EN_WEB.pdf. Accessed at 18.03.2020. 7.Micro Mega. The One G Brochure. Available at: https://micro-mega.com/wp-content/uploads/2018/03/OneG_EN1_15_web.pdf. Accessed at 18.03.2020. 8.Dentsply. Wave One Gold Brochure. Available at: https://www.dentsplysirona.com/content/dam/dentsply/pim/en_GB/Endodontics/Obturation/Paper_Points/WaveOne_Gold_Absorbent_Points/WaveOne%20GOLD%20Brochure%202015.pdfAccessed at 18.03.2020. 9.Vorster M, van de Vyver PJ, Paleker F. Canal Transportation and Centering Ability ofWaveOneGoldin Combination with and without Different Glide Path Techniques. J Endod2018; 44: 1430-1435. 10.Dhingra A, Kochar R, Banerjee S, Srivastava P. Comparative evaluation of the canal curvature modifications after instrumentation with One Shape rotary and Wave One reciprocating files.J Conserv Dent2014; 17: 138 11.Pedulla E, Leanza G, La Rosa GRM, et al. Cutting efficiency of conventional and heat-treated nickel–titanium rotary or reciprocating glide path instruments. Int Endod J 2020; 53: 376-384. 12.Saleh AM, Gilani PV, Tavanafar S, Schafer E. Shaping Ability of 4 Different Single-file Systems in Simulated S-shaped Canals. J Endod 2015; 41: 548-552. 13.Özyürek T, Yılmaz K, Uslu G. Shaping ability of Reciproc, WaveOne GOLD, and HyFlex EDM single-file systems in simulated S-shaped canals. J Endod 2017;43:805-809. 14.Ates AA, Arıcan B, Işık V. Comparison of Shaping Ability of XP-Endo Shaper in Simulated J-Shaped Canals with Various Sizes. Journal of Research in Medical and Dental Science 2020;8:176-181. 15.Ersev H, Yi