Dergiler / Diagnostic and Interventional Radiology / 2005 / Cilt: 11 - Sayı: 1

Three-dimensional imaging and cone beam volume CT in C-arm angiography with flat panel detector

Sayfa
10–13
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Present status of the technique, advantages and potential applications are discussed.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:We evaluated a new 3D angiography system with a flat panel detector (FPD) for its capabilitiy to acquire volume sets during a single rotation scan and to reconstruct high spatial resolution three-dimensional and cross sectional images, namely cone beam volume computed tomography (CBVCT) images.
📊
Temel Bulgular & Veri:We evaluated a new 3D angiography system with a flat panel detector (FPD) for its capabilitiy to acquire volume sets during a single rotation scan and to reconstruct high spatial resolution three-dimensional and cross sectional images, namely cone beam volume computed tomography (CBVCT) images.
💡
Sonuç & Katkı:Present status of the technique, advantages and potential applications are discussed.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Tomografi · x-ışınlı bilgisayarlı · Anjiyografi

Abstract

We evaluated a new 3D angiography system with a flat panel detector (FPD) for its capabilitiy to acquire volume sets during a single rotation scan and to reconstruct high spatial resolution three-dimensional and cross sectional images, namely cone beam volume computed tomography (CBVCT) images. Present status of the technique, advantages and potential applications are discussed.

🔖

Bu Makaleye Atıf Yap

AKPEK, S., BRUNNER, T., BENNDORF, G., STROTHER, C. (2005). Three-dimensional imaging and cone beam volume CT in C-arm angiography with flat panel detector. Diagnostic and Interventional Radiology, Cilt: 11 - Sayı: 1, 10–13. https://ajindex.com/articles/216821

Kaynakça (8)

  1. Wiesent K, Barth K, Navab N, Durlak P, Brunner T, Schuetz O, Seissler W. Enhanced 3D-reconstruction algorithm for C-arm systems suitable for interventional procedures. IEEE Trans Med Imaging 2000; 19:391-403
  2. Feldkamp LA, Davis LC, Kress JW. Practical cone-beam algorithm. J Opt Soc Am 1984; 1:612-619
  3. Sukovic P. Cone beam computed tomography in craniofacial imaging. Orthod Craniofacial Res 2003; 6(Suppl. 1):31-36
  4. Boone JM, Nelson TR, Lindfors KK, Seibert JA. Dedicated breast CT: radiation dose and image quality evaluation. Radiology 2001; 221:657-667
  5. Fahrig R, Fox AJ, Lownie S, Holdsworth DW. Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results. AJNR Am J Neuroradiol 1997; 18:1507-1514
  6. Baba R, Konno Y, Ueda K, Ikeda S. Comparison of flat-panel detector and image- intensifier detector for cone-beam CT. Comput Med Imaging Graph 2002; 26: 153-158
  7. Flohr T, Stierstorfer K, Bruder H, Simon J, Schaller S. New technical developments in multislice CT, part 1: approaching isotropic resolution with sub-millimeter 16-slice scanning. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 2002; 174:839-845
  8. El-Sheik M, Heverhagen JT, Alfke H, Froelich JJ, Hornegger J, Brunner T, Klose KJ, Wagner HJ. Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: initial results. Radiology 2001; 221: 843-849.