Dergiler / Glokom Katarakt / 2013 / Cilt: 8 - Sayı: 1

Glokomda ex-press shunt implantasyon cerrahisinin göz içi basıncına etkisi

The ıntraocular pressure effect of ex-press shunt ımplantation surgery in glaucoma

Sayfa
31–35
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Bulgular: Hastaların ortalama takip süresi 12.4±7.1 (1-30) aydı.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Çeşitli glokom tiplerinde Ex-Press shunt implantasyon cerrahisinin göz içi basıncı (GİB) üzerine etkisinin de- ğerlendirilmesi.
📊
Temel Bulgular & Veri:Gereç ve Yöntem: Bu geriye dönük çalışmaya 9 neovasküler, 6 psödoeksfolyatif, 5 kronik açı kapanması, 1 keratoplasti sonrası, 1 üveitik, 2 silikona bağlı, 2 primer açık açılı, 2 hayalet hücreli, 1 afakik enflamatuvar ve 1 travmatik glokomu olan 30 göz dahil edildi.
💡
Sonuç & Katkı:Bulgular: Hastaların ortalama takip süresi 12.4±7.1 (1-30) aydı.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Amaç: Çeşitli glokom tiplerinde Ex-Press shunt implantasyon cerrahisinin göz içi basıncı (GİB) üzerine etkisinin de- ğerlendirilmesi. Gereç ve Yöntem: Bu geriye dönük çalışmaya 9 neovasküler, 6 psödoeksfolyatif, 5 kronik açı kapanması, 1 keratoplasti sonrası, 1 üveitik, 2 silikona bağlı, 2 primer açık açılı, 2 hayalet hücreli, 1 afakik enflamatuvar ve 1 travmatik glokomu olan 30 göz dahil edildi. Gözlerin 10’unda diyabetik retinopati, 3’ünde ön üveit öyküsü, 1’inde geçirilmiş retina dekolmanı cer- rahisi, 1’inde travmatik retina dekomanı, 1’inde travmatik vitreus hemarojisi ve lens dislokasyonu, 3’ünde travma öyküsü, 1’inde santral retinal ven oklüzyonu, 1’inde dejeneratif miyopi mevcuttu. Yedi göze (%23) eşzamanlı fakoemulsifikasyon cerrahisi yapıldı. Glokom ilacı kullanmadan GİB≤18 mmHg olması tam başarı, glokom ilacı kullanarak GİB≤18 mmHg olması sınırlı başarı, glokom ilaçlarına rağmen GİB>18 mmHg olması veya ek glokom cerrahisi gerekmesi başarısızlık ola- rak değerlendirildi. Veriler istatistiksel olarak analiz edildi. Bulgular: Hastaların ortalama takip süresi 12.4±7.1 (1-30) aydı. Ameliyat öncesi ortalama 39.3±12.8 mmHg olan GİB 16.4±10.8 mmHg’ya geriledi (p<0.000). 17 (%57) gözde tam başarı, 7 (%23) gözde sınırlı başarı, 6 (%20) gözde başarısız- lık elde edildi. Ortalama görme keskinliği (ETDRS) ameliyat öncesi 4/20±4/40 (n=16), ameliyat sonrası 4/10±4/20 (n=13) saptandı. Ortalama kullanılan antiglokomatöz ilaç kutu sayısı 2.7±0.4 kutudan 0.7±0.9 kutuya indi (p<0.000). Ameliyat sonrası dönemde 3 (%10) gözde vitreus hemorojisi, 6 (%20) gözde hifema, 9 (%30) gözde koroid dekolmanı, 1 (%3) gözde bleb disestezisi gelişti. Sonuç: Ex-Press shunt implantasyonu çoğu komplike glokomdan oluşan gözlerde ortalama 12 aylık takip sonrasında GİB’nın kontrolü açısından %80 oranında tam veya sınırlı başarı gösterebilmektedir.

Abstract

Purpose: To test the intraocular pressure (IOP) effect of the Ex-Press shunt implantation surgery in various types of glaucoma. Materials and Methods: In this retrospective study 30 eyes of 29 patients with neovascular, pseudoexfoliative, chronic angle-closure, post-keratoplasty, üveitic, due to silicone, primary open-angle, ghost-cell, traumatic aphakic, inflammatory glaucoma were included. The eyes were complicated with diabetic retinopathy in 10 eyes, a history of anterior uveitis in 3 eyes, the previous retinal detachment surgery in 1 eye, traumatic retinal detachment in 1 eye, traumatic vitreous hemor- rhage and lens dislocation in 1 eye, trauma in 3 eyes, central retinal vein occlusion in 1 eye and degenerative myopia in 1 eye. Phacoemulsification surgery was performed to 7 eyes (23%) simultaneously. Complete success was defined as IOP&#8804;18 mmHg without glaucoma medications, limited success was defined as IOP&#8804;18 mmHg using glaucoma medications, failure was defined as despite the glaucoma medications IOP>18 mmHg or additional glaucoma surgery is required to be assessed. Results: The average follow-up was 12.4±7.1 (range 1-30) months. The mean preoperative IOP was 39.3±12.8 mmHg and significantly decreased to 16.4±10.8 mmHg in postoperative period. (p<0.000). At 12 months folllow up complete success rates were 57%, limited success were 23%, failure were 20%. Conclusion: Ex-Press shunt implantation surgery had 80% full or limited IOP control rate success in most complicated glaucoma eyes with an average of 12 months follow-up.

🔖

Bu Makaleye Atıf Yap

BURAN, D., KOCATÜRK, T., ÇAKMAK, H., DAYANIR, V. (2013). Glokomda ex-press shunt implantasyon cerrahisinin göz içi basıncına etkisi. Glokom Katarakt, Cilt: 8 - Sayı: 1, 31–35. https://ajindex.com/articles/214230

Kaynakça (10)

  1. Quigley HA, Broman AT. The number of people with glaucoma worldwide in 2010 and 2020. Br J Ophthalmol 2006;90:262-7
  2. Mantravadi AV, Myers JS. Reconsidering trabeculectomy’s strengths and weaknesses Clin Experiment Ophthalmol. 2010;38:827-8
  3. Traverso CE, De Feo F, Messas-Kaplan A et al. Long term effect on IOP of a stainless steel gloucoma drainage implant (Ex-Press) in combined surgery with phacoemulsification. Br J Ophthalmol 2005;89:425-9
  4. Dahan E, Carmichael TR. Implantation of a miniature glau- coma device under a scleral flap. J Glaucoma 2005;14:98-102
  5. Wamsley S, Moster MR, Rai S et al. Results of the use of the Ex-Press miniature glaucoma implant in technically challeng- ing, advanced gloucoma cases: a clinical pilot study. Am J Ophthalmol 2004;138:109-51
  6. Stewart RM, Diamond JG, Ashmore ED et al. Complications following Ex-Press gloucoma shunt implantation. Am J Oph- thalmol 2005;140:340-1
  7. Sarıcaoğlu MS, Karakurt A, Hasıripi H. Glokom ve katarakt birlikteliğine cerrahi yaklaşım Glo-Kat 2006;1:71-6
  8. Heffelfinger BL, Berman MN, Krupin T, et al. Surgical man- agementof coexisting glaucoma and cataract. Ophthalology Clinics of North America 2000;13:545-52
  9. Maris PJ Jr, Ishida K, Netland PA. Comparison of trabecu- lectomy with Ex-Press miniature glaucoma device implanted under scleral flap. J Glaucoma 2007;16:14-9. 10. de Jong LA. The Ex-Press glaucoma shunt versus trabeculec- tomy in open-angle glaucoma: a prospective randomized study 2009;26:336-45. 11. de Jong L, Lafuma A, Aguadé AS et al. Five-year extension of a clinical trial comparing the Ex-Press glaucoma filtration device and trabeculectomy in primary open-angle glaucoma. Clin Ophthalmol 2011;5:527-33
  10. Freedman J. What is new after 40 years of glaucoma implants. J Glaucoma 2010;19:504-8.