Dergiler / Glokom Katarakt / 2013 / Cilt: 8 - Sayı: 3

Primer açık açılı glokomda perifoveal ganglion hücre kompleksi kalınlığının spektral domain optik koherans tomografi ile değerlendirilmesi

The measurement of perifoveal ganglion cell complex thickness by spectral domain optic coherence tomography in primary open-angle glaucoma

Sayfa
153–158
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Bulgular: Çalışmaya dahil edilen tüm olgularda ortalama yaş 55.4 (±8.2; 38-75) idi ve kadın/erkek oranı 31/15 idi.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Primer açık açılı glokomlu gözlerde fovea santraline odaklanmış 3.4mm’lik dairesel optik koherans tomografi kesitinde (OKT) gang- lion hücre kompleks (GHK) kalınlığının değerlendirilmesi amaçlandı.
📊
Temel Bulgular & Veri:Gereç ve Yöntem: Kliniğimiz glokom biriminde takipli primer açık açılı glokom tanılı 30 hastanın 60 gözü ve kontrol grubu olarak 16 sağlıklı gönüllünün 32 gözü çalışmaya dahil edildi.
💡
Sonuç & Katkı:Bulgular: Çalışmaya dahil edilen tüm olgularda ortalama yaş 55.4 (±8.2; 38-75) idi ve kadın/erkek oranı 31/15 idi.
🔬Tür:Deneysel Tarla Denemesi
📍Kapsam:30 hasta
⚙️Değişkenler:Alan Parametreleri

Özet

Amaç: Primer açık açılı glokomlu gözlerde fovea santraline odaklanmış 3.4mm’lik dairesel optik koherans tomografi kesitinde (OKT) gang- lion hücre kompleks (GHK) kalınlığının değerlendirilmesi amaçlandı. Gereç ve Yöntem: Kliniğimiz glokom biriminde takipli primer açık açılı glokom tanılı 30 hastanın 60 gözü ve kontrol grubu olarak 16 sağlıklı gönüllünün 32 gözü çalışmaya dahil edildi. Tüm olgulara spektral domain optik koherans tomografi (SD-OKT) (Heidelberg Spect- ralis HRA/OCT) ile peripapiller retina sinir lifi tabakası (RSLT) kalınlığı ölçümü yapıldı. Ardından 3.4 mm’lik dairesel OKT kesiti fovea santralinde odaklanarak çekim tekrarlandı. Ölçülen perifoveal RSLT kalınlığının dış referans çizgisi iç pleksiform tabakanın alt sınırına manuel olarak kaydırılarak GHK kalınlığı değerlendirildi. Glokomlu gözlerde elde edilen ölçüm sonuçları kontrol grubu ile karşılaştırıldı. Ayrıca glokomlu olgularda standart otomatik perimetri (Humphrey Alan Analizörü II, Model 750) ile SITA-standart testinde ölçülen görme alanındaki ortalama sapma (MD) değerleri kaydedildi. İstatistiksel analizde bağımlı ve bağımsız değişkenler arasında t-testi ve Pearson korelasyon testi kullanıldı. Bulgular: Çalışmaya dahil edilen tüm olgularda ortalama yaş 55.4 (±8.2; 38-75) idi ve kadın/erkek oranı 31/15 idi. Ortalama peripapiller RSLT kalınlığı glokom grubunda 105.9±17.5 μm ve kontrol grubunda 115.9±9.4 μm ölçüldü. Glokomlu gözlerde RSLT kalınlığı istatistiksel olarak anlamlı düşük bulundu (p=0.003). Ortalama perifoveal GHK kalınlığı ise glokomlu gözlerde ve kontrol grubunda sırasıyla 85.6±19.6 μm ve 98.1±9.5 μm bulundu. GHK kalınlığı da glokomlu grupta istatistiksel olarak anlamlı derecede inceydi (p<0.001). Glokomlu gözlerde GHK kalınlığı ve peripapiller RSLT kalınlığı arasında yüksek oranda pozitif yönde korelasyon saptandı (r2=0.806). Perifoveal GHK ve peripapiller RSLT kalınlığı ile görme alanındaki MD değerleri arasındaki korelasyona bakıldığında da her iki parametre için anlamlı ko- relasyon görüldü (sırasıyla r2=0.528 ve r2=0.490). Sonuç: Perifoveal ganglion hücre kompleks kalınlığı glokomlu gözlerde normal gözlere kıyasla daha düşüktür ve glokomun erken tanı ve takibinde yol gösterici bir parametre olabilir.

Abstract

Purpose: To evaluate the ganglion cell complex (GCC) thickness in primary open angle glaucoma with a 3.4 mm circular optic coherence tomography section focused on the central fovea. Material and Methods: Sixty eyes of 30 primary open angle glaucoma patients who were treated in the glaucoma unit of our clinic and 32 eyes of 16 controls were enrolled. Peripapillary retinal nerve fiber layer (RNFL) thickness was measured in all patients with a spectral domain optic coherence tomography (SD-OCT), (Heidelberg Spectralis HRA/OCT). The scan was repeated after the center of the 3,4 mm circular OCT section was focused on central fovea. Ganglion cell complex thickness was measured by changing the outer reference line of RNFL to the outer border of inner plexiform layer manually. The results of glaucomatous eyes were compared with controls. Mean deviation (MD) values of the visual field was also recorded with standard automated perimetry (Humphrey Field Analyzer II, Model 750) and SITA- standard test. T-test and Pearson correlation test were used in statistical analysis of dependent and independent samples. Results: Mean age of all enrolled subjects was 55.4 (±8.2; 38-75) and women to men ration was 31/15. Mean peripapillary RNFL thickness was measured 105.9±17.5 &#956;m and 115.9±9.4 &#956;m in glaucoma and control group respectively. The thinner RNFL thickness in glaucomatous eyes was statistically significant (p=0.003). Mean GCC thickness was recorded 85.6±19.6 &#956;m and 98.1±9.5 &#956;m in glaucomatous eyes and controls, respectively. GCC was also significantly thinner in the glaucoma group (p<0.001). There was high positive correlation between GCC and RNFL thickness in glaucomatous eyes (r2=0.806). Also there was a siginificant correlation between MD and perifoveal GCC as well as beween MD and peripapillary RNFL (r2=0.528 and r2=0.490 respectively). Conclusions: Perifoveal ganglion cell complex thickness is thinner in glaucoma compared with normal eyes. This can be a parameter in early diagnosis and management of glaucoma.

🔖

Bu Makaleye Atıf Yap

PARLAK, M., DÖNMEZ, O., ARIKAN, G., GÜNENÇ, Ü. (2013). Primer açık açılı glokomda perifoveal ganglion hücre kompleksi kalınlığının spektral domain optik koherans tomografi ile değerlendirilmesi. Glokom Katarakt, Cilt: 8 - Sayı: 3, 153–158. https://ajindex.com/articles/213649

Kaynakça (15)

  1. Zeimer R, Asrani S, Zou S et al. Quantitative detection of glaucomatous damage at the posterior pole by retinal thick- ness mapping: A pilot study. Ophthalmology 1998;105:224-31
  2. İncel O, Tekeli O, Turaçlı E. Normal basınçlı glokom hastalarında heidelberg retina tomografi, tarayıcı laser polarimetri ile görme alanı parametreleri arasındaki ilişki. GloKat 2009;4:168-73
  3. Aydın A, Bilge AH. Optik koherens tomografinin glokomda yeri. Glo-Kat 2007;2:77-82
  4. Huang D, Swanson EA, Lin CP et al. Optical coherence tomog- raphy. Science 1991;254:1178-81
  5. Savini G, Carbonelli M, Barboni P. Spectral-domain optical coherence tomography for the diagnosis and follow-up of glau- coma. Curr Opin Ophthalmol 2011;22:115-23
  6. Ayhan Z, Arıkan G, Günenç Ü et al. Primer açık açılı glokom, normal tansiyonlu glokom ve oküler hipertansiyonda humphrey görme alanı, optik koherens tomografi ve heidelberg retina tomografi parametrelerinin korelasyonu. T Oft Gaz 2011;41:143-50
  7. Kotowski J, Folio LS, Wollstein G et al. Glaucoma discrimination of segmented cirrus spectral domain optical coherence tomography (SD-OCT) macular scans. Br J Ophthalmol 2012;96:1420-5
  8. Morooka S, Hangai M, Nukada M et al. Wide 3-dimensional macular ganglion cell complex imaging with spectral-domain optical coherence tomography in glaucoma. Invest Ophthal- mol Vis Sci 2012;53:4805-12
  9. Chen J, Huang H, Wang M et al. Fourier domain OCT mea- surement of macular ganglion cell complex, and peripapillary RNFL thickness in glaucomatous Chinese eyes. Eur J Oph- thalmol 2012;22:972-9
  10. Ishikawa H, Stein DM, Wollstein G et al. Macular segmenta- tion with optical coherence tomography. Invest Ophthalmol Vis Sci 2005;46:2012-7
  11. Quigley HA, Dunkelberger GR, Green WR. Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma. Am J Ophthalmol 1989;107:453-64
  12. Glovinsky Y, Quigley H, Pease ME. Foveal ganglion cell loss is size dependent in experimental glaucoma. Invest Ophthalmol Vis Sci 1993;34:395-400
  13. Schuman JS, Pedut-Kloizman T, Hertzmark E et al. Reproduc- ibility of nerve fiber layer thickness measurements using opti- cal coherence tomography. Ophthalmology 1996;103:1889-98
  14. Leung CK, Chan WM, Yung WH et al. Comparison of macular and peripapillary measurements for the detection of glauco- ma: an optical coherence tomography study. Ophthalmology 2005;112:391-400
  15. Schulze A, Lamparter J, Pfeiffer N et al. Diagnostic ability of retinal ganglion