Biomechanical comparison of headless antegrade screw versus retrograde cortical screw for coronoid fracture fixation (EXPERIMENTAL STUDY)

Sayfa
307–310
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion: The present study failed to show that anterior-to-posterior directed headless screw fixation of coronoid fractures could adequately replace posterior-to-anterior placed screw fixation.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: Posterior-to-anterior directed screws are stronger than anterior-to-posterior directed screws for coronoid fracture fixation.
📊
Temel Bulgular & Veri:The present study was based on the hypothesis that anterior-to-posterior headless screw (Acutrak Mini® 3.5 mm × 26 mm, Acumed, Hillsboro, Oregon, USA) fixation of coronoid fractures would be as strong as posterior-to-anterior 2.7 mm Association for Osteosynthesis (AO) cortical screw fixation.
💡
Sonuç & Katkı:Conclusion: The present study failed to show that anterior-to-posterior directed headless screw fixation of coronoid fractures could adequately replace posterior-to-anterior placed screw fixation.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Objective: Posterior-to-anterior directed screws are stronger than anterior-to-posterior directed screws for coronoid fracture fixation. Anterior approaches that facilitate direct reduction and fixation of coronoid fractures have been described. The present study was based on the hypothesis that anterior-to-posterior headless screw (Acutrak Mini® 3.5 mm × 26 mm, Acumed, Hillsboro, Oregon, USA) fixation of coronoid fractures would be as strong as posterior-to-anterior 2.7 mm Association for Osteosynthesis (AO) cortical screw fixation. Methods: This study included 14 ulnas obtained from 14 formalin-preserved adult cadavers. Coronoid type 2 fractures were created and fixed randomly using anterior-to-posterior headless screws (antegrade group) and posterior-to-anterior 2.7 mm AO cortical screws (retrograde group). The experimental constructs were loaded until 2 mm of displacement. Failure load (N), fixation stiffness (Nmm–1), and indentation stiffness were calculated. Results: Failure load was higher in the retrograde screw group (p=0.03), whereas loading stiffness values of the fixation devices and bones did not differ between the 2 fixation groups (p>0.05). Conclusion: The present study failed to show that anterior-to-posterior directed headless screw fixation of coronoid fractures could adequately replace posterior-to-anterior placed screw fixation.

🔖

Bu Makaleye Atıf Yap

HAPA, O., KARAKAŞLI, A., DİNÇER, C., ZHAMILOV, V., GÜVENÇER, M., HAVITÇIOĞLU, H. (2015). Biomechanical comparison of headless antegrade screw versus retrograde cortical screw for coronoid fracture fixation (EXPERIMENTAL STUDY). Acta Orthopaedica et Traumatologica Turcica, Cilt: 49 - Sayı: 3, 307–310. https://ajindex.com/articles/212559

Kaynakça (18)

  1. Clarke SE, Lee SY, Raphael JR. Coronoid fixation using suture anchors. Hand (N Y) 2009;4:156–60
  2. McKay PL, Katarincic JA. Fractures of the proximal ulna olecranon and coronoid fractures. Hand Clin 2002;18:43– 53
  3. O’Driscoll SW, Jupiter JB, Cohen MS, Ring D, McKee MD. Difficult elbow fractures: pearls and pitfalls. Instr Course Lect 2003;52:113–34
  4. O’Driscoll S. Coronoid fractures. In: Norris TR, editor. Orthopedic knowledge update: shoulder and elbow. Rosemont, IL: American Academy of Orthpaedic Surgeons; 2002. p. 379–84
  5. Cohen MS. Fractures of the coronoid process. Hand Clin 2004;20:443–53
  6. Doornberg JN, van Duijn J, Ring D. Coronoid fracture height in terrible-triad injuries. J Hand Surg Am 2006;31:794–7
  7. Moon JG, Zobitz ME, An KN, O’Driscoll SW. Optimal screw orientation for fixation of coronoid fractures. J Orthop Trauma 2009;23:277–80
  8. Kang LQ, Ding ZQ, Sha M, Hong JY, Chen W. A minimally invasive anterior approach to reduction and screw fixation of coronoid fractures. J Hand Surg Eur Vol 2010;35:224–7
  9. Zhang C, Zhong B, Luo CF. Treatment strategy of terrible triad of the elbow: experience in Shanghai 6th People’s Hospital. Injury 2014;45:942–8
  10. Han SH, Yoon HK, Rhee SY, Lee JK. Anterior approach for fixation of isolated type III coronoid process fracture. Eur J Orthop Surg Traumatol 2013;23:395–405
  11. Hartzler RU, Llusa-Perez M, Steinmann SP, Morrey BF, Sanchez-Sotelo J. Transverse coronoid fracture: when does it have to be fixed? Clin Orthop Relat Res 2014;472:2068– 74
  12. Morrey BF. Complex instability of the elbow. Instr Course Lect 1998;47:157–64
  13. Ring D. Fractures of the coronoid process of the ulna. J Hand Surg Am 2006;31:1679–89
  14. McKee MD, Pugh DM, Wild LM, Schemitsch EH, King GJ. Standard surgical protocol to treat elbow dislocations with radial head and coronoid fractures. Surgical technique. J Bone Joint Surg Am 2005;87 Suppl 1(Pt 1):22– 32
  15. Garofalo R, Bollmann C, Kombot C, Moretti B, Borens O, Mouhsine E. Minimal invasive surgery for coronoid fracture: technical note. Knee Surg Sports Traumatol Arthrosc 2005;13:608–11
  16. Reichel LM, Milam GS, Reitman CA. Anterior approach for operative fixation of coronoid fractures in complex elbow instability. Tech Hand Up Extrem Surg 2012;16:98–104
  17. Elkowitz SJ, Kubiak EN, Polatsch D, Cooper J, Kummer FJ, Koval KJ. Comparison of two headless screw designs for fixation of capitellum fractures. Bull Hosp Jt Dis 2003;61:123–6
  18. Hausman MR, Klug RA, Qu