Dergiler / Diagnostic and Interventional Radiology / 2017 / Cilt: 23 - Sayı: 5

Lesion characteristics, histopathologic results, and follow-up of breast lesions after MRI-guided biopsy

Sayfa
333–338
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Further multicenter studies with larger patient population are needed to elucidate these results.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:PURPOSE We aimed to assess the effectiveness of magnetic resonance imaging (MRI)-guided vacuum-assisted breast biopsy (VABB), evaluate and compare the characteristics and histopathologic findings of lesions, and overview the follow-up results of benign lesions.
📊
Temel Bulgular & Veri:METHODS MRI findings and histopathologic results of breast lesions biopsied by MRI-guided VABB between 2013 and 2016 were retrospectively analyzed.
💡
Sonuç & Katkı:Further multicenter studies with larger patient population are needed to elucidate these results.
🔬Tür:Araştırma Makalesi
📍Kapsam:2013 Verileri
⚙️Değişkenler:Alan Parametreleri

Abstract

PURPOSE We aimed to assess the effectiveness of magnetic resonance imaging (MRI)-guided vacuum-assisted breast biopsy (VABB), evaluate and compare the characteristics and histopathologic findings of lesions, and overview the follow-up results of benign lesions. METHODS MRI findings and histopathologic results of breast lesions biopsied by MRI-guided VABB between 2013 and 2016 were retrospectively analyzed. MRI findings closely related with malignancy were investigated in particular. Follow-up results of benign lesions were evaluated. RESULTS MRI-guided VABB was applied to 116 lesions of 112 women. Of the lesions, 75 (65%) were benign, while 41 (35%) were malignant. Segmental (94%), clustered (89%), and clustered ring (67%) nonmass-like enhancement patterns were found to be more related with malignancy. False-negative rate of MRI-guided VABB was 12%, underestimation rate was 21%. One of the 54 followed-up benign lesions had a malignant result. CONCLUSION MRI-guided VABB is a reliable method for the diagnosis of breast lesions that are positive only on MRI. Follow-up results show that cancer detection rate is low for radio-pathologically concordant lesions. Further multicenter studies with larger patient population are needed to elucidate these results.

🔖

Bu Makaleye Atıf Yap

TAŞKIN, F., SOYDER, A., TANYERİ, A., ÖZTÜRK, V. S., ÜNSAL, A. (2017). Lesion characteristics, histopathologic results, and follow-up of breast lesions after MRI-guided biopsy. Diagnostic and Interventional Radiology, Cilt: 23 - Sayı: 5, 333–338. https://ajindex.com/articles/198240

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (16)

  1. Mann RM, Kuhl CK, Kinkel K, Boetes C. Breast MRI: guidelines from the European society of breast imaging. Eur Radiol 2008; 18:1307–1318
  2. Spick C, Baltzer PA. Diagnostic utility of second-look US for breast lesions identified at MR imaging: systematic review and meta-analysis. Radiology 2014; 273:401–409
  3. Mostbeck G. Second look US after breast MRI. Ultraschall Med 2015; 36:101–103
  4. Liberman L, Bracero N, Morris E, Thornton C, Dershaw DD. MRI-guided 9-Gauge vacuum-assisted breast biopsy: initial clinical experience. AJR Am J Roentgenol 2005; 185:183–193
  5. Perlet C, Heywang-Kobrunner SH, Heinig A, et al. Magnetic resonance-guided, vacuum-assisted breast biopsy: results from a European multicenter study of 538 lesions. Cancer 2006; 106:982–999
  6. Fischer U, Schwethelm L, Baum FT, Luftner-Nagel S, Teubner J. Effort, accuracy and histology of MR-guided vacuum biopsy of suspicious breast lesions--retrospective evaluation after 389 interventions. Rofo 2009; 181:774–781
  7. Malhaire C, El Khoury C, Thibault F, et al. Vacuum-assisted biopsies under MR guidance: results of 72 procedures. Eur Radiol 2010; 20:1554–1562
  8. Spick C, Schernthaner M, Pinker K, et al. MR-guided vacuum-assisted breast biopsy of MRI-only lesions: a single center experience. Eur Radiol 2016; 26:3908–3916
  9. Ferre R, Ianculescu V, Ciolovan L, et al. Diagnostic performance of MR-guided vacuum-Assisted breast biopsy: 8 years of experience. The Breast J 2016; 22:83–89
  10. BI-RADS: Breast Imaging Reporting and Data System, Atlas, 5th Ed. ACR 2013, Reston, VA, USA
  11. Strigel RM, Eby PR, Demartini WB, et al. Frequency, upgrade rates, and characteristics of high risk lesions initially identified with breast MRI. AJR Am J Roentgenol 2010; 195:792–798
  12. Clauser P, Cassano E, De Nicolò A, et al. Foci on breast magnetic resonance imaging in highrisk women: cancer or not? Radiol Med 2016; 121:611–617
  13. Liberman L, Mason G, Morris EA, Dershaw DD. Does size matter? Positive predictive value of MRI-detected breast lesions as a function of lesion size. AJR Am J Roentgenol 2006; 186:426–430
  14. Ha R, Sung J, Lee C, et al. Characteristics and outcome of enhancing foci followed on breast MRI with management implications. Clin Radiol 2014; 69:715–720
  15. Dietzel M, Baltzer PA, Vag T, et al. Differential diagnosis of breast lesions 5 mm or less: is there a role for magnetic resonance imaging? J Comput Assist Tomogr 2010; 34:456–464
  16. Ha R, Comstock CE. Breast magnetic resonance imagi