Dergiler / Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering / 2017 / Cilt: 18 - Sayı: 3

A FLUORESCENT FILM PROBE BASED ON SCHIFF BASE FOR DETERMINATION OF Fe3+ IONS

Sayfa
611–623
Yayın Tarihi
2017-09-30
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Fluorescence data indicated that the proposed sensor has potential application to determination of Fe3+ cations in deionized water without interference of the used other metal cations.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In this paper, fluorescent film probe based on Schiff base was easily prepared and it used as fluorescence chemosensor for the detection of transition metal ions in aqueous medium.
📊
Temel Bulgular & Veri:Fluorescence measurements were done using fluorescence spectroscopy and the obtained results showed that the proposed sensor have two emission maxima at 539 and 582 nm.
💡
Sonuç & Katkı:Fluorescence data indicated that the proposed sensor has potential application to determination of Fe3+ cations in deionized water without interference of the used other metal cations.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Schiff base · Chemosensor · Fe (III) ion

Abstract

In this paper, fluorescent film probe based on Schiff base was easily prepared and it used as fluorescence chemosensor for the detection of transition metal ions in aqueous medium. Fluorescence measurements were done using fluorescence spectroscopy and the obtained results showed that the proposed sensor have two emission maxima at 539 and 582 nm. In addition, the proposed film sensor exhibited high sensitivity and selectivity to Fe3+ cation in the mentioned wavelengths. Quantum yield of the fluorescent sensor was also calculated as 3.24%. The limit of detection (LOD) of the chemosensor was calculated using fluorescence titration method and it determined as 53.7 and 3.53 µM at 539 and 582 nm. Fluorescence data indicated that the proposed sensor has potential application to determination of Fe3+ cations in deionized water without interference of the used other metal cations.

🔖

Bu Makaleye Atıf Yap

KAMACI, M. (2017). A FLUORESCENT FILM PROBE BASED ON SCHIFF BASE FOR DETERMINATION OF Fe3+ IONS. Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering, Cilt: 18 - Sayı: 3, 611–623. https://ajindex.com/articles/196893

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Hua CJ, Zheng H, Zhang K, Xin M, Gao JR, Li YJ. A novel turn off fluorescent sensor for Fe(III) and pH environment based on coumarin derivatives: the fluorescence characteristics and theoretical study. Tetrahedron 2016; 72: 8365-8372.
  2. Antheraidis AN, Zachariadis GA, Stratis JA. Gallium trace on-line pre-concentration/separation and determination using a polyurethane foam mini-column and flame atomic absorption spectrometry. Application in aluminum alloys, natural waters and urine. Talanta 2003; 60: 929–936.
  3. Wang Y, Liu Z, Sun J, Liu X, Pei M, Zhang G. A turn-on fluorescence probe for Fe3+ based-on benzimidazo[2,1-a] benz[de]isoquinoline-7-one derivatives. J Photoch Photobio A 2017; 332: 515–520.
  4. Long Q, Wen Y, Li H, Zhang Y, Yao S. A novel fluorescent biosensor for detection of silver ions based on upconversion nanoparticles, J Fluoresc 2017; 27: 205–211.
  5. Cheng X, Yu Y, Jia Y, Duan L. Fluorescent PU films for detection and removal of Hg2+, Cr3+ and Fe3+ ions. Mater Design 2016; 95: 133–140.
  6. Wei J, Ren J, Liu J, Meng X, Ren X, Chen Z, Tang F. An eco-friendly, simple, and sensitive fluorescence biosensor for the detection of choline and acetylcholine based on C-dots and the Fenton reaction. Biosens Bioelectron 2014; 52: 304–309.
  7. Dwivedi AK, Saikia G, Iyer PK. Aqueous polyfluorene probe for the detection and estimation of Fe3+ andinorganic phosphate in blood serum. J Mater Chem 2011; 21: 2502–2507.
  8. Wu X, Xu B, Tong H, Wang L. Phosphonate-functionalized polyfluorene film sensors for sensitive detection of iron (III) in both organic and aqueous media. Macromolecules 2010; 43: 8917–8923.
  9. Yang Y, Huo FJ, Yin C, Chao J, Zhang Y. An ‘OFF-ON’ fluorescent probe for specially recognize on Cys and its application in bio-imaging. Dyes Pigments 2015; 114: 105-109.
  10. Saleem M, Lee KH. Selective fluorescence detection of Cu2+ in aqueous solution and living cells. J Lumin 2014; 145: 843–848.
  11. Xiao W, Chen Z. Fluorescent Iron (III) Determination Based on Salicylaldehyde Functionalized Bimodal Mesoporous Silica, J Nanosci Nanotechnol 2016; 16: 12666–12670.
  12. Bhamore JR, Jha S, Singhal RK, Kailasa SK. Synthesis of water dispersible fluorescent carbon nanocrystals from syzygium cumini fruits for the detection of Fe3+ ion in water and biological samples and imaging of fusarium avenaceum cells. J Fluoresc 2017; 27: 125–134
  13. Wang M, Meng G, Huang Q, Qiaoling Xu Q, Guodong Liu G. A GBI@PPyNWs-based prototype of reusable fluorescence sensor for the detection of Fe3+ in aqueous solution. A