Dergiler / Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering / 2017 / Cilt: 18 - Sayı: 5

PREPARATION OF A MODIFIED ELECTRODE FOR THE DETERMINATION OF LEVOFLOXACIN

Sayfa
962–972
Yayın Tarihi
2017-12-31
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Finally, the performance of the prepared electrode was tested in the determination of LEV in human blood serum, urine and pharmaceutical samples.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In this study, modification of glassy carbon electrode with electrochemically reduced graphene oxide (ERGO) and acid treated multi-walled carbon nanotubes (A-MWCNT) was investigated for the voltammetric determination of LEV in body fluids and pharmaceutical products.
📊
Temel Bulgular & Veri:The prepared modified electrode showed electrocatalytic acitivity towards LEV oxidation by increasing oxidation peak currents 293 times.
💡
Sonuç & Katkı:Finally, the performance of the prepared electrode was tested in the determination of LEV in human blood serum, urine and pharmaceutical samples.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Levofloxacin · graphene oxide · multi-walled carbon nanotube

Abstract

In this study, modification of glassy carbon electrode with electrochemically reduced graphene oxide (ERGO) and acid treated multi-walled carbon nanotubes (A-MWCNT) was investigated for the voltammetric determination of LEV in body fluids and pharmaceutical products. Different combinations of GO, ERGO, MWCNT and A-MWCNT were searched and the best results obtained with GC/ERGO/A-MWCNT electrode. The prepared modified electrode showed electrocatalytic acitivity towards LEV oxidation by increasing oxidation peak currents 293 times. Characterizations of the modified electrode was performed with cyclic voltammetry, electrochemical impedance spectroscopy and raman measurements. The highest oxidation peak current was observed at pH value of 2.0. The oxidation peak currents of LEV increased linearly with the concentration of LEV in the range of 0.01 mM and 10 mM. The detection limit of the prepared sensor was determined as 0.0063 mM. After three weeks’ storage, the prepared electrode showed high stability by preserving 93% of its original activity towards 1.0 mM LEV. The prepared electrode successfully discriminates the voltammetric response of LEV from that of other fluoroquinolone antibiotics (enoxacin, norfloxacin, ciprofloxacin). Finally, the performance of the prepared electrode was tested in the determination of LEV in human blood serum, urine and pharmaceutical samples.

🔖

Bu Makaleye Atıf Yap

ÖZCAN, A. A., GÜRBÜZ, M., ÖZCAN, A. (2017). PREPARATION OF A MODIFIED ELECTRODE FOR THE DETERMINATION OF LEVOFLOXACIN. Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering, Cilt: 18 - Sayı: 5, 962–972. https://ajindex.com/articles/196677

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (8)

  1. Basu P.P., Rayapudi K., Pacana T., Shah N.J., Krishnaswamy N., Flynn M. A Randomized Study Comparing Levofloxacin, Omeprazole, Nitazoxanide, and Doxycycline versus Triple Therapy for the Eradication of Helicobacter pylori. Am J Gastroenterol 2011; 106; 1970–1975. Aguilar‐Carrasco J.C., Hernández‐Pineda J., Jiménez‐Andrade J.M., Flores‐Murrieta F.J., Carrasco‐Portugal M.C., López‐Canales J.S. Rapid and sensitive determination of levofloxacin in microsamples of human plasma by high‐performance liquid chromatography and its application in a pharmacokinetic study. Biomed Chromatogr 2015; 29; 341–345.
  2. Wang F., Zhu L., Zhang J. Electrochemical sensor for levofloxacin based on molecularly imprinted polypyrrole-graphene-gold nanoparticles modified electrode. Sens Actuat B Chem 2014; 192; 642–647.
  3. Locatelli M., Ciavarella M.T., Paolino D., Celia C., Fiscarelli E., Ricciotti G., Pompilio A., Bonaventura G.D., Grande R., Zengin G., Marzio L.D. Determination of ciprofloxacin and levofloxacin in human sputum collected from cystic fibrosis patients using microextraction by packed sorbent-high performance liquid chromatography photodiode array detector, J. Chromatogr. A. 2015; 1419; 58–66.
  4. Lee S.J., Desta K.T., Eum S.Y., Dartois V., Cho S.N., Bae D.W., Shin S.C. Development and validation of LC-ESI-MS/MS method for analysis of moxifloxacin and levofloxacin in serum of multidrug-resistant tuberculosis patients: Potential application as therapeutic drug monitoring tool in medical diagnosis. J. Chromatogr B Anal Technol Biomed Life Sci 2016; 1009–1010; 138–143.
  5. Herrera-Herrera A.V., Ravelo-Pérez L.M., Hernández-Borges J., Afonso M.M., Palenzuela J.A., Rodríguez-Delgado M.Á. Oxidized multi-walled carbon nanotubes for the dispersive solid-phase extraction of quinolone antibiotics from water samples using capillary electrophoresis and large volume sample stacking with polarity switching. J Chromatogr A 2011; 1218;5352–5361.
  6. Shao X., Li Y., Liu Y., Song Z. Flow injection chemiluminescence determination of levofloxacin in medicine and biological fluids based on its enhancing effect on luminol-H2O2 reaction. Spectroscopy 2009; 23; 209–216.
  7. Mazzotta E., Malitesta C., Díaz-Álvarez M., Martin-Esteban A. Electrosynthesis of molecularly imprinted polypyrrole for the antibiotic levofloxacin. Thin Solid Films 2012; 520; 1938–1943.
  8. Tang L., Tong Y., Zheng R., Liu W., Gu Y., Li C., Chen R., Zhang Z. Ag nanoparticles and electrospun CeO2-Au composite nanofibers modified glassy carbon elect