Dergiler / Astım Allerji İmmünoloji / 2019 / Cilt: 17 - Sayı: 2

Cell-Mediated Cytotoxicity Assays

Sayfa
61–69
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

More recently, flow cytometric methods using fluorescent monoclonal antibodies such as anti-CD56 for effector and anti-CD33 for target cells have been defined.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Cell-mediated cytotoxicity measurements can be divided in two methods, depending on whether radioactive material is used or not.
📊
Temel Bulgular & Veri:Natural Killer cell-mediated cytotoxicity is routinely measured with a short-term assay by labeling the target cells with radioactive chromium (51Cr).
💡
Sonuç & Katkı:More recently, flow cytometric methods using fluorescent monoclonal antibodies such as anti-CD56 for effector and anti-CD33 for target cells have been defined.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Cell-mediated cytotoxicity measurements can be divided in two methods, depending on whether radioactive material is used or not. Natural Killer cell-mediated cytotoxicity is routinely measured with a short-term assay by labeling the target cells with radioactive chromium (51Cr). The advantages of this method are (1) highly sensitivity, (2) easy execution, (3) low spontaneous release, and (4) nontoxic markers. The disadvantages include short half-life of the label and handling and disposal of radioactive supplies. Many attempts have been made to adapt this cytotoxicity assay to abolish radioactivity while maintaining its high sensitivity. Consequently, various nonradioactive methods have been developed. One of these methods utilizing the release of enzymes (LDH) as a result of cytolysis or membrane dyes (PKH-26) is usually less sensitive than radioactive assays. MTT-based colorimetric/enzymatic assays are highly sensitive and easy to use but unfortunately works only with adherent tumor cell targets. Fluorescent dyes such as carboxy-fluorescein diacetate can easily accumulate in the cytoplasm of effector or target cells. After cytotoxicity, the release of the dyes into the supernatant or their retention in target cells is calculated. However, spontaneous release of these dyes can be quite high, causing false positive results leading to a decreased sensitivity and restricting their use in short-term assays. More recently, flow cytometric methods using fluorescent monoclonal antibodies such as anti-CD56 for effector and anti-CD33 for target cells have been defined.

🔖

Bu Makaleye Atıf Yap

ÖZDEMİR, Ö. (2019). Cell-Mediated Cytotoxicity Assays. Astım Allerji İmmünoloji, Cilt: 17 - Sayı: 2, 61–69. https://ajindex.com/articles/189811

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Zamai L, Ahmad M, Bennett IM, Azzoni L, Alnemri ES, Perussia B. Natural killer (NK) cell-mediated cytotoxicity: Differential use of TRAIL and Fas ligand by immature and mature primary human NK cells. J Exp Med 1998;188(12):2375-80
  2. Sieni E, Cetica V, Mastrodicasa E, Pende D, Moretta L, Griffiths G, et al. Familial hemophagocytic lymphohistiocytosis: A model for understanding the human machinery of cellular cytotoxicity. Cell Mol Life Sci 2012;69(1):29-40
  3. Suck G, Branch DR, Smyth MJ, Miller RG, Vergidis J, Fahim S, et al. KHYG-1, a model for the study of enhanced natural killer cell cytotoxicity. Exp Hematol 2005;33(10):1160-71
  4. Valiathan R, Lewis JE, Melillo AB, Leonard S, Ali KH, Asthana D. Evaluation of a flow cytometry-based assay for natural killer cell activity in clinical settings. Scand J Immunol 2012;75(4):455- 62
  5. Goldberg JE, Sherwood SW, Clayberger C. A novel method for measuring CTL and NK cell-mediated cytotoxicity using annexin V and two-color flow cytometry. J Immunol Methods 1999; 224(1-2):1-9
  6. Ozdemir O, Savaşan S. Combinational IL-2/IL-15 induction does not further enhance IL-15-induced lymphokine-activated killer cell cytotoxicity against human leukemia/lymphoma cells. Clin Immunol 2005;115(3):240-9
  7. Zaritskaya L, Shurin MR, Sayers TJ, Malyguine AM. New flow cytometric assays for monitoring cell-mediated cytotoxicity. Expert Rev Vaccines 2010;9(6):601-16
  8. Kasatori N, Ishikawa F, Ueyama M, Urayama T. A differential assay of NK-cell-mediated cytotoxicity in K562 cells revealing three sequential membrane impairment steps using three-color flow-cytometry. J Immunol Methods 2005;307(1-2):41-53
  9. Ozdemir O, Ravindranath Y, Savaşan S. Cell-mediated cytotoxicity evaluation using monoclonal antibody staining for target or effector cells with annexinV/propidium iodide colabeling by fluorosphere-adjusted counts on three color flow cytometry. Cytometry A 2003;56(1):53-60
  10. Brunner KT, Mauel J, Cerottini JC, Chapuis B. Quantitative assay of the lytic action of immune lymphoid cells on 51-Crlabelled allogeneic target cells in vitro; Inhibition by isoantibody and by drugs. Immunology 1968;14(2):181-96
  11. King MA. Detection of dead cells and measurement of cell killing by flow cytometry. J Immunol Methods 2000;243:155-66
  12. Roder JC, Haliotis T, Klein M, Korec S, Jett JR, Ortaldo J, et al. A new immunodeficiency disorder in humans involving NK cells. Nature 1980;284(5756):553-5
  13. Morales A, Ottenhof PC. Clinical appl