Dergiler / Turkish Journal of Electrical Engineering and Computer Science / 2013 / Cilt: 21 - Sayı: 3

Investigation of the telluric effects arising along the cathodically protected natural gas pipeline between Karadeniz Ereğli and Düzce

Sayfa
758–765
Yayın Tarihi
2013-03-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

In conclusion, it was found that these changes did not arise at a certain period or at any point between the Düzce PIG and Ereğli RMS station, although it did occur strongly around the Akal Take-Off.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Cathodic protection is one of the most widely used applications for protecting underground and submarine metallic structures from corrosion.
📊
Temel Bulgular & Veri:This study is aimed at ascertaining the existence, arising frequency, and magnitude of an interference called the telluric effect that is going in and out of the natural gas pipeline between Düzce and Karadeniz Ereğli in Turkey, which is 60 km in length and has a 40.64 cm diameter, and is well coated with polyethylene.
💡
Sonuç & Katkı:In conclusion, it was found that these changes did not arise at a certain period or at any point between the Düzce PIG and Ereğli RMS station, although it did occur strongly around the Akal Take-Off.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Corrosion · telluric effect · cathodic protection

Özet

Cathodic protection is one of the most widely used applications for protecting underground and submarine metallic structures from corrosion. This method is based on providing the electrons, which metallic structures lose as a result of electrolytic reaction, by the cathodic protection system. However, from time to time, it may be possible that there is some unwanted interference input into the metallic structure in such applications. This study is aimed at ascertaining the existence, arising frequency, and magnitude of an interference called the telluric effect that is going in and out of the natural gas pipeline between Düzce and Karadeniz Ereğli in Turkey, which is 60 km in length and has a 40.64 cm diameter, and is well coated with polyethylene. In this study, the pipe/ground potential values, electrical currents coming from the anode bed, and soil resistivity values were measured at different times and regions along the pipeline. In conclusion, it was found that these changes did not arise at a certain period or at any point between the Düzce PIG and Ereğli RMS station, although it did occur strongly around the Akal Take-Off.

Abstract

Cathodic protection is one of the most widely used applications for protecting underground and submarine metallic structures from corrosion. This method is based on providing the electrons, which metallic structures lose as a result of electrolytic reaction, by the cathodic protection system. However, from time to time, it may be possible that there is some unwanted interference input into the metallic structure in such applications. This study is aimed at ascertaining the existence, arising frequency, and magnitude of an interference called the telluric effect that is going in and out of the natural gas pipeline between Düzce and Karadeniz Ereğli in Turkey, which is 60 km in length and has a 40.64 cm diameter, and is well coated with polyethylene. In this study, the pipe/ground potential values, electrical currents coming from the anode bed, and soil resistivity values were measured at different times and regions along the pipeline. In conclusion, it was found that these changes did not arise at a certain period or at any point between the Düzce PIG and Ereğli RMS station, although it did occur strongly around the Akal Take-Off.

🔖

Bu Makaleye Atıf Yap

DEMİREL, B., YALÇIN, H. (2013). Investigation of the telluric effects arising along the cathodically protected natural gas pipeline between Karadeniz Ereğli and Düzce. Turkish Journal of Electrical Engineering and Computer Science, Cilt: 21 - Sayı: 3, 758–765. https://ajindex.com/articles/188616

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (8)

  1. D.H. Boteler, R.J. Pijola, H. Nevanlinna, “The effect of geomagnetic disturbances on electrical systems at the Earth’s surface”, Advances in Space Research, Vol. 22, pp. 1–21, 1998.
  2. N.J. Allison, W.E. Huddleston, “Extraneous currents noted on large transmission pipe line system”, NACE International - The Corrosion Society, Vol. 8, p. 1, 1952. W.H. Campbell, “Induction of auroral zone electric currents within the Alaska pipeline”, Pure and Applied Geophysics, Vol. 116, pp. 1143–1173, 1978.
  3. J. Morgan, Cathodic Protection, Houston, NACE International, 1987. T.G. Proctor, “Experience with telluric current interference in the cathodic protection of a buried pipeline in New Zealand”, Materials Performance, Vol. 13, pp. 6–24, 1974. Wikipedia, “Telluric current,” at http://en.wikipedia.org/wiki/Telluric current, accessed on 18 December 2011.
  4. R. Pirjola, A. Viljanen, A. Pulkkinen, J. Amm, “Space weather risk in power systems and pipelines”, Physics and Chemistry of the Earth Part C, Vol. 25, pp. 333–347, 2000.
  5. A. Ashworth, C. Googan, Cathodic Protection Theory and Practice, West Sussex, Ellis Horwood Ltd., 1993.
  6. L.L. Shreir, Corrosion Control, London, Newness-Butterworths, 1972.
  7. A.W. Peabody, Control of Pipeline Corrosion, Houston, NACE International, 1967.
  8. R.A. Gummow, P. Eng, “GIC effects on pipeline corrosion and corrosion control systems”, Journal of Atmospheric and Solar-Terrestrial Physics, Vol. 64, pp. 1755–1764, 2002.