Dergiler / Turkish Journal of Electrical Engineering and Computer Science / 2013 / Cilt: 21 - Sayı: Sup.1

A combined protective scheme for fault classification and identification of faulty section in series compensated transmission lines

Sayfa
1842–1856
Yayın Tarihi
2012-12-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The proposed method not only provides a good classification performance for all types of faults, but also detects the faulty section at a high accuracy.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The fault detection process is very difficult in transmission lines with a fixed series capacitor because of the nonlinear behavior of protection device and series-parallel resonance.
📊
Temel Bulgular & Veri:In the proposed method, the fault detection process is carried out by using distinctive features of 3-line signals (line voltages and currents) and zero sequence current.
💡
Sonuç & Katkı:The proposed method not only provides a good classification performance for all types of faults, but also detects the faulty section at a high accuracy.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Fault classification · faulty section identification · series compensated transmission line

Özet

The fault detection process is very difficult in transmission lines with a fixed series capacitor because of the nonlinear behavior of protection device and series-parallel resonance. This paper proposes a new method based on S-transform (ST) and support vector machines (SVMs) for fault classification and identification of a faulty section in a transmission line with a fixed series capacitor placed at the middle of the line. In the proposed method, the fault detection process is carried out by using distinctive features of 3-line signals (line voltages and currents) and zero sequence current. The relevant features of these signals are obtained by using the ST. The obtained features are then used as input to multiple SVM classifiers and their outputs are combined for classifying the fault type and identifying the faulty section. Training and testing samples for the proposed method have been generated with different types of short-circuit faults and different combinations of system parameters in the MATLAB environment. The performance of the proposed method is investigated according to the accuracy of fault classification and faulty section identification. To evaluate the validity of this study, the proposed method is also compared to both ST--neural network and previous studies. The proposed method not only provides a good classification performance for all types of faults, but also detects the faulty section at a high accuracy.

Abstract

The fault detection process is very difficult in transmission lines with a fixed series capacitor because of the nonlinear behavior of protection device and series-parallel resonance. This paper proposes a new method based on S-transform (ST) and support vector machines (SVMs) for fault classification and identification of a faulty section in a transmission line with a fixed series capacitor placed at the middle of the line. In the proposed method, the fault detection process is carried out by using distinctive features of 3-line signals (line voltages and currents) and zero sequence current. The relevant features of these signals are obtained by using the ST. The obtained features are then used as input to multiple SVM classifiers and their outputs are combined for classifying the fault type and identifying the faulty section. Training and testing samples for the proposed method have been generated with different types of short-circuit faults and different combinations of system parameters in the MATLAB environment. The performance of the proposed method is investigated according to the accuracy of fault classification and faulty section identification. To evaluate the validity of this study, the proposed method is also compared to both ST--neural network and previous studies. The proposed method not only provides a good classification performance for all types of faults, but also detects the faulty section at a high accuracy.

🔖

Bu Makaleye Atıf Yap

ÇÖTELİ, R. (2012). A combined protective scheme for fault classification and identification of faulty section in series compensated transmission lines. Turkish Journal of Electrical Engineering and Computer Science, Cilt: 21 - Sayı: Sup.1, 1842–1856. https://ajindex.com/articles/188577

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (9)

  1. J. Woodworth, “MOV protection of series capacitor banks”, Arrester Factors008, 2008. Available at http://arresterworks.com/ArresterFacts files/ArresterFacts%20008%20-%20MOV%20Protection%20of%20Series%20 Capacitor%20Banks.pdf. A.K. Pradhan, A. Routray, S. Pati, D.K. Pradhan, “Wavelet-fuzzy combined approach for fault classification of a series-compensated transmission line”, IEEE Transactions on Power Delivery, Vol. 19, pp. 1612–1618, 2005.
  2. U.B. Parikh, B. Das, R. Maheshwari, “Fault classification technique for series compensated transmission line using support vector machine”, International Journal of Electrical Power and Energy Systems, Vol. 32, pp. 629–636, 2010. O. ¨ Ozg¨ onenel, G. ¨ Onbilgin, C ¸. Kocaman, “Transformer protection using the wavelet transform”, Turkish Journal of Electrical Engineering & Computer Sciences, Vol. 13, pp. 119–135, 2005. E. Kılı¸ c, O. ¨ Ozg¨ onenel, ¨ O. Usta, D. Thomas, “PCA based protection algorithm for transformer internal faults”, Turkish Journal of Electrical Engineering & Computer Sciences, Vol. 17, pp. 125–142, 2009.
  3. M.A. Khan, O. Ozgonenel, M.A. Rahman, “Wavelet transform based protection of stator faults in synchronous generators”, Electric Power Components and Systems, Vol. 35, pp. 625–637, 2007.
  4. O. Ozgonenel, E. Kilic, M.A. Khan, M.A. Rahman, “A new method for fault detection and identification of incipient faults in power transformers”, Electric Power Components and Systems, Vol. 36, pp. 1226–1244, 2008.
  5. U.B. Parikh, B. Das, R.P. Maheshwari, “Combined wavelet-SVM technique for fault zone detection in a series compensated transmission line”, Transactions on Power Delivery, Vol. 23, pp. 1789–1794, 2008.
  6. A.K. Pradhan, A. Routray, B. Biswal, “Higher order statistics-fuzzy integrated scheme for fault classi?cation of a series compensated line”, Transactions on Power Delivery, Vol. 19, pp. 891–893, 2004.
  7. Q.Y. Xaun, Y.H. Song, A.T. Johns, R. Morgan, D. Williams, “Performance of an adaptive protection scheme for series compensated EHV transmission systems using neural networks”, Electric Power System Research, Vol. 36, pp. 57–66, 1996.
  8. D. Novosel, B. Bachman, D. Hart, Y. Hu, M.M. Saha, “Algorithms for locating faults on series compensated lines using neural network and deterministic methods”, Transactions on Power Delivery, Vol. 11, pp. 1728–1736, 1996.
  9. Y.H. Song, A.T. Johns, Q.Y. Xuan, “Artificial neural network based protection scheme for controllable series compensated EHV transmission lines”, IEE Proceedings: Gen