Dergiler / Turkish Journal of Electrical Engineering and Computer Science / 2016 / Cilt: 24 - Sayı: 4

Enhancement of a reduced order doubly fed induction generator model for wind farm transient stability analyses

Sayfa
2124–2134
Yayın Tarihi
2016-08-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

It has been seen that the system becomes stable in a short time when the rotor dynamic is included in a reduced order DFIG model.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:(DFIG) implemented for wind power systems is very important for transient stability.
📊
Temel Bulgular & Veri:The performances of reduced order DFIG models with/without RDM have been compared.
💡
Sonuç & Katkı:It has been seen that the system becomes stable in a short time when the rotor dynamic is included in a reduced order DFIG model.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Doubly fed induction generator (DFIG) · reduced order model (ROM) · rotor dynamic modeling (RDM)

Abstract

(DFIG) implemented for wind power systems is very important for transient stability. The rotor dynamic model (RDM) as well as the reduced order model (ROM) of a DFIG has been developed for transient analysis purpose. The performances of reduced order DFIG models with/without RDM have been compared. Modeling and analyses have been carried out in MATLAB/SIMULINK. Comparison of system behaviors against 3 phase fault is made between without RDM and with RDM. Several parameters such as output voltage, active power, speed, electrical torque variations, and d-q axis stator and rotor current variations of the DFIG along with a 34.5 kV bus voltage have been examined. In addition, the responses of DFIG output voltage and electrical torque have been compared for the cases of full order and reduced order DFIG models with rotor dynamics. It has been seen that the system becomes stable in a short time when the rotor dynamic is included in a reduced order DFIG model.

🔖

Bu Makaleye Atıf Yap

DÖŞOĞLU, M. K., ARSOY, A. B. (2016). Enhancement of a reduced order doubly fed induction generator model for wind farm transient stability analyses. Turkish Journal of Electrical Engineering and Computer Science, Cilt: 24 - Sayı: 4, 2124–2134. https://ajindex.com/articles/187895