Dergiler / Turkish Journal of Electrical Engineering and Computer Science / 2016 / Cilt: 24 - Sayı: 4

Modeling and control of a 6-control-area interconnected power system to protect the network frequency applying different controllers

Sayfa
2205–2219
Yayın Tarihi
2016-08-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Therefore, the PI-based fuzzy logic controller has been chosen as the best control solution to bring the grid frequency back to its nominal value as quickly as possible after occurrence of load variations.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In this paper, we first analyze and build a model of the 6-control-area interconnected power system as the typical case study.
📊
Temel Bulgular & Veri:Subsequently, different frequency controllers based on tie-line bias control strategy, namely integral, proportional--integral, proportional--integral--derivative, and PI-based fuzzy logic, will be investigated and applied to the power system model.
💡
Sonuç & Katkı:Therefore, the PI-based fuzzy logic controller has been chosen as the best control solution to bring the grid frequency back to its nominal value as quickly as possible after occurrence of load variations.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:2013 Verileri
⚙️Değişkenler:Interconnected power system · deviation · frequency

Abstract

In this paper, we first analyze and build a model of the 6-control-area interconnected power system as the typical case study. Subsequently, different frequency controllers based on tie-line bias control strategy, namely integral, proportional--integral, proportional--integral--derivative, and PI-based fuzzy logic, will be investigated and applied to the power system model. The most important control performances, such as overshoots and settling times, are considered in this study to evaluate the stability of the power system and choose the most suitable controller for maintaining the network frequency. The simulation results have been achieved by using MATLAB/Simulink package version 2013 in this work. According to these results, the maximum overshoots of the PI-based fuzzy logic controller are from 36.56{\%} to 90.13{\%}, and its settling times are from 19.00{\%} to 98.26{\%} in comparison with the other regulators in the given control power system. Therefore, the PI-based fuzzy logic controller has been chosen as the best control solution to bring the grid frequency back to its nominal value as quickly as possible after occurrence of load variations.

🔖

Bu Makaleye Atıf Yap

NGUYEN, N., HUANG, Q., DAO, T. (2016). Modeling and control of a 6-control-area interconnected power system to protect the network frequency applying different controllers. Turkish Journal of Electrical Engineering and Computer Science, Cilt: 24 - Sayı: 4, 2205–2219. https://ajindex.com/articles/187894

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...