A novel perturbed particle swarm optimization-based support vector machine for fault diagnosis in power distribution systems

Sayfa
518–529
Yayın Tarihi
2018-02-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The proposed approaches are tested on a typical two-lateral radial distribution network.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In this paper, a novel perturbed particle swarm optimization (PPSO) algorithm is investigated to improve the performance of a support vector machine (SVM) for short-circuit fault diagnosis in power distribution systems.
📊
Temel Bulgular & Veri:For the purpose of fault diagnosis, the time- domain re ectometry (TDR) method with pseudorandom binary sequence (PRBS) excitation is considered to generate the necessary fault simulation data set.
💡
Sonuç & Katkı:The proposed approaches are tested on a typical two-lateral radial distribution network.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Fault diagnosis · particle swarm optimization · power distribution networks support vector machine

Abstract

In this paper, a novel perturbed particle swarm optimization (PPSO) algorithm is investigated to improve the performance of a support vector machine (SVM) for short-circuit fault diagnosis in power distribution systems. In the proposed PPSO algorithm, the velocity of each particle is perturbed whenever the particles strike into a local optimum, in order to achieve a higher quality solution to optimization problems. Furthermore, the concept of proposed perturbation is applied to three variants of PSO, and improved corresponding algorithms are named perturbed C-PSO (PC-PSO), perturbed T-PSO (PT-PSO), and perturbed K-PSO (PK-PSO). For the purpose of fault diagnosis, the time- domain re ectometry (TDR) method with pseudorandom binary sequence (PRBS) excitation is considered to generate the necessary fault simulation data set. The proposed approaches are tested on a typical two-lateral radial distribution network.

🔖

Bu Makaleye Atıf Yap

THOM, H. T., MING-YUAN, C., TUAN, V. Q. (2018). A novel perturbed particle swarm optimization-based support vector machine for fault diagnosis in power distribution systems. Turkish Journal of Electrical Engineering and Computer Science, Cilt: 26 - Sayı: 1, 518–529. https://ajindex.com/articles/187161