Ultrasonografi Eşliğinde Vena Jugularis İnterna Kateterizasyonunda İki Farklı Baş Pozisyonunun (Nötral Pozisyon, 45° Rotasyon) İşlem Süresine ve Komplikasyonlara Etkisi

Effects of Two Different Head Positions (Neutral Position, and 45° Rotation) on Procedural Time and Complication Rates During Ultrasound Guided Internal Jugular Venous Catheterization

Sayfa
45–49
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Bulgular: Vena jugularis internanın karotis artere göre yerle- şim yeri, iki grup arasında anlamlı farklılık gösterdi (p 0.05).

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Santral ven kateterizasyonunda, infeksiyon ve komplikasyon oranları daha düşük olması nedeniyle vena jugularis interna tercih edilmekte, ultrasonografi kullanımı ise başarıyı artırmaktadır.
📊
Temel Bulgular & Veri:Çalışmamızda yoğun bakımda USG ile santral ven kateterizasyonunda başın iki farklı pozisyonuna (nötral pozisyon ve 45° rotasyon pozisyonu) bağlı vena jugularis internanın yer değiştirmesinin işlem süresi ve komplikasyonlara olan etkisini değerlendirdik.
💡
Sonuç & Katkı:Bulgular: Vena jugularis internanın karotis artere göre yerle- şim yeri, iki grup arasında anlamlı farklılık gösterdi (p 0.05).
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Amaç: Santral ven kateterizasyonunda, infeksiyon ve komplikasyon oranları daha düşük olması nedeniyle vena jugularis interna tercih edilmekte, ultrasonografi kullanımı ise başarıyı artırmaktadır. Çalışmamızda yoğun bakımda USG ile santral ven kateterizasyonunda başın iki farklı pozisyonuna (nötral pozisyon ve 45° rotasyon pozisyonu) bağlı vena jugularis internanın yer değiştirmesinin işlem süresi ve komplikasyonlara olan etkisini değerlendirdik. Gereç ve Yöntem: Kateterizasyon işleminin baş karşı tarafa 45° çevrildiği (n=50) ve nötral baş pozisyonunda (n=50) uygulandığı grup olarak olgular rastgele iki gruba ayrıldı. İşlem süreleri ve komplikasyonları kaydedildi. Bulgular: Vena jugularis internanın karotis artere göre yerle- şim yeri, iki grup arasında anlamlı farklılık gösterdi (p 0.05). Tartışma ve Sonuç: VJİ kateterizasyonu sırasında boyun rotasyonu anatomik işaretlerin görünürlüğünü arttırabilir, ancak artmış boyun rotasyonu VJİ'nin karotis arterin anterioruna gelmesine neden olur ve arter ponksiyon riskini arttırır. Çalışmamızda nötral pozisyonda VJİ'nin anterior yerleşim oranının daha az olmasına rağmen, USG eşliğinde girişim yapıldığı için bu durumun arter ponksiyon riskini artırmadığı gösterilmiştir. Nötral baş pozisyonunda işlem sahası daha küçük olduğu için uygulama zorluğu olmasına rağmen, çalışmamızda her iki grupta işlem süreleri açısından fark bulunmamıştır. Bu durumun başa pozisyon verilemeyen travma hastalarında avantaj olabileceği görüşündeyiz.

Abstract

Objective: Internal jugular vein is preferred for central venous catheterization because of lower infection and complication rates and ultrasound- guidance increases success rates. In this study we evaluated the effect of internal jugular vein displacement in relation to carotid artery depending on the two different head positions(neutral position vs. 45° rotation) on procedural time and complication rates. Material and Methods: Patients were randomly assigned into two groups where catheterization was performed at 45° contralateral head rotation group or neutral head position group. Access times and complications were recorded. Results: Position of the internal jugular vein in relation to carotid artery was significantly different between two groups (p 0.05). Discussion and Conclusion: In IJV catheterization, head rotation may enhance the visibility of anatomical landmarks, but it it may also increase the risk of carotid artery puncture by replacing the position of the IJV in relation to the CA. In our study, it has been shown that anterior placement of the IJV in the neutral position is less frequently seen, but this has no advantage in avoiding arterial puncture. Smaller area of procedure in a neutral position can cause difficulties in practice. However, the procedural times between each head position were not different. Nevertheless, further studies are needed which will investigate whether comparable complication rates and procedural times can be realized in both emergency and trauma patients in whom head rotation cannot be performed.

🔖

Bu Makaleye Atıf Yap

KURT, M., ÖZGÜLTEKİN, A., AYTEKİN, H., AYTEKİN, A., KÖSEOĞLU, Y., EKİNCİ, O. (2016). Ultrasonografi Eşliğinde Vena Jugularis İnterna Kateterizasyonunda İki Farklı Baş Pozisyonunun (Nötral Pozisyon, 45° Rotasyon) İşlem Süresine ve Komplikasyonlara Etkisi. Göğüs Kalp Damar Anestezi ve Yoğun Bakım Derneği Dergisi, Cilt: 22 - Sayı: 2, 45–49. https://ajindex.com/articles/178065

Kaynakça (12)

  1. Denys BG, Uretsky BF, Reddy PS. Ultrasound-assisted cannulation of the internal jugular vein. A prospective comparison to the external landmark-guided technique. Circulation 1993;87:1557-62.
  2. Troianos C, Kuwik R, Pasqual J, Lim A, Odasso D. Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography. Anesthesiology 1996;85:43-8.
  3. Lieberman JA, Williams KA, Rosenberg AL. Optimal head rotation for internal jugular vein cannulation when relying on external landmarks. Anesth Analg 2004;99:982-88.
  4. Gwak M, Park J, Suk F, Kim D. Effects of head rotation on the right internal jugular vein in infants and young children. Anesthesia 2010;65:2727-36.
  5. Takeyama K, Kobayashi H, Suzuki T. Optimal puncture site of the right internal jugular vein after larengeal mask airway placement. Anesthesiology 2005;103:1136-41.
  6. Calvert N, Hind D, McWilliams R, Davidson A, et al. Ultrasound for central venous cannulation: economic evaluation of cost-effectiveness. Anaesthesia 2004;59:1116-20.
  7. Forauer AR, Glockner JF. Importance of US findings in Access planning during jugular vein hemodialysis catheter placements. J Vasc Interv Radiol 2000;11:233-8.
  8. Willeford KL, Reitan JA. Neutral head position for placement of internal jugular vein catheters. J Anesth 1994;49:202-4.
  9. Karakitsos D, Labropoulos N, De Groot E, Patrianakos AP, Kouraklis G, et al. Real-time ultrasoundguided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients. Crit Care 2006;10:R162.
  10. Turker G, Kaya FN. Internal juguler vein cannulation: an Ultrasoundguided technique versus a Landmarkguided technique. Clinics 2009;64(10):989-92.
  11. Blaivas M. Video analysis of accidental arterial cannulation with dynamic ultrasound guidance for central venous access. J Ultrasound Med 2009;28:1239-44
  12. Domino KB, Bowdle TA, Posner KL, Spitellie PH, Lee LA, Cheney FW. Injuries and liability related to central vascular catheters: a cl