Dergiler / The Turkish Journal Of Occupational / Environmental Medicine and Safety / 2026 / Cilt: Volume 2 Sayı: İssue 1 (1)

EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD

Sayfa
276–276
Yayın Tarihi
2017-02-16
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

In conclusion the absence of a continuous release of BPA from the dental materials is important in the clinical sense.  

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Bisphenol A (BPA) is a chemical produced in large quantities for use primarily in the production of polycarbonate plastics and epoxy resins.
📊
Temel Bulgular & Veri:The resins were placed into a silicon mold (diameter: 5 mm; thickness: 2 mm) on a teflon plate and photopolymerized by LED light source using two different modes [Full-Mod (Mod-1) and Ramping Mod (Mod-2)].
💡
Sonuç & Katkı:In conclusion the absence of a continuous release of BPA from the dental materials is important in the clinical sense.  
🔬Tür:Makale
📍Kapsam:2000 Verileri
⚙️Değişkenler:EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD · EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD

Abstract

Bisphenol A (BPA) is a chemical produced in large quantities for use primarily in the production of polycarbonate plastics and epoxy resins. BPA is also present in dental materials used to treat and prevent caries. There have been concerns raised regarding the safety of bisphenol A in dental sealants and composites. The aim of the study is to measure BPA levels which were released from composite resins after curing with different polymerization conditions. Four composite resins which are commonly used in dental clinics were used in the study. The resins were placed into a silicon mold (diameter: 5 mm; thickness: 2 mm) on a teflon plate and photopolymerized by LED light source using two different modes [Full-Mod (Mod-1) and Ramping Mod (Mod-2)]. After polymerization, cured composite resin specimens were soaked in 3 ml artificial saliva and stored at 37 C for 16 days. After 2 h, 24 h, 3 d, 7 d and 15 d, 250 µl specimens were taken in order to detect BPA release from dental resins by HPLC-UV detection. The linear ranges were found to be 5-2000 ppb. The regression equation was y=2.6726x-4.6396 (r =0.9993). Maximum and minimum BPA release from dental composites detected in Mod 1 were 174.04±9.7 and 9.30±0.16 while 10.15±0.3 and 218.0±9.5 in Mod 2, respectively. Release of BPA from dental restorative materials was ended after 15 days. In conclusion the absence of a continuous release of BPA from the dental materials is important in the clinical sense.  

🔖

Bu Makaleye Atıf Yap

Asci, A., Derelioglu, S. S., Yilmaz, B., Gurbuz, T., Songur, F. (2017). EVALUATION OF BPA LEVELS RELEASED FROM DIFFERENT DENTAL RESTORATIVE MATERIALS USING HPLC METHOD. The Turkish Journal Of Occupational / Environmental Medicine and Safety, Cilt: Volume 2 Sayı: İssue 1 (1), 276–276. https://ajindex.com/articles/1659917

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (2)

  1. Ali ASCİ, Sera Simsek DERELİOGLU, Bilal YİLMAZ, Taskin GURBUZ, Fatma SONGUR.
  2. Atatürk University, Faculty of Pharmacy, Department of Toxicology, Erzurum, Turkey Atatürk University, Faculty of Dentistry, Department of Pedodontics, Erzurum, Turkey Atatürk University, Faculty of Pharmacy, Department of Analytical Chemistry, Erzurum, Turkey