Dergiler / The Turkish Journal Of Occupational / Environmental Medicine and Safety / 2017 / Cilt: 2 Sayı: 1(4)

FAST DETECTION OF ACETYLSALICYLIC ACID BY LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY(LC-MSMS)

Sayfa
30–30
Yayın Tarihi
2017-11-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

This method has capability to determine these levels.   Conclusion We can conclude that the developed method can be useful for clinical studies and routine therapeutic drug monitoring with the desired precision and accuracy.   Keywords Salicylic toxicity, tandem mass, high performance, chromatography.   Acknowledgments: No conflict of interest

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objectives Acetylsalicylic acid (ASA) is the most widely used as an analgesic, anti-inflammatory and antipyretic drug, and also used to inhibit cyclooxygenase dependent platelet aggregation.   The aim of this study was to develop a simple, fast and accurate tandem mass method for determination and quantification of ASA.   Methods Chromatographic seperation was performed using an Shimadzu LC-20-AD (Kyoto, Japan) coupled with a ABSCIEX API 3200 triple quadrupole massspectrometer (USA) equipped with an electrospray ion source (ESI) operating in negative mode.   Results Intraassay CV values for acetylsalicylic acid were 8% and 6% for 0.8 and 100 µg/L, respectively.   Discussion The narrow therapeutic range of these drugs are of importance to be analyzed at critical concentrations.
📊
Temel Bulgular & Veri:Objectives Acetylsalicylic acid (ASA) is the most widely used as an analgesic, anti-inflammatory and antipyretic drug, and also used to inhibit cyclooxygenase dependent platelet aggregation.   The aim of this study was to develop a simple, fast and accurate tandem mass method for determination and quantification of ASA.   Methods Chromatographic seperation was performed using an Shimadzu LC-20-AD (Kyoto, Japan) coupled with a ABSCIEX API 3200 triple quadrupole massspectrometer (USA) equipped with an electrospray ion source (ESI) operating in negative mode.   Results Intraassay CV values for acetylsalicylic acid were 8% and 6% for 0.8 and 100 µg/L, respectively.   Discussion The narrow therapeutic range of these drugs are of importance to be analyzed at critical concentrations.
💡
Sonuç & Katkı:This method has capability to determine these levels.   Conclusion We can conclude that the developed method can be useful for clinical studies and routine therapeutic drug monitoring with the desired precision and accuracy.   Keywords Salicylic toxicity, tandem mass, high performance, chromatography.   Acknowledgments: No conflict of interest
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:FAST DETECTION OF ACETYLSALICYLIC ACID BY LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY(LC-MSMS) · FAST DETECTION OF ACETYLSALICYLIC ACID BY LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY(LC-MSMS)

Abstract

Objectives Acetylsalicylic acid (ASA) is the most widely used as an analgesic, anti-inflammatory and antipyretic drug, and also used to inhibit cyclooxygenase dependent platelet aggregation.   The aim of this study was to develop a simple, fast and accurate tandem mass method for determination and quantification of ASA.   Methods Chromatographic seperation was performed using an Shimadzu LC-20-AD (Kyoto, Japan) coupled with a ABSCIEX API 3200 triple quadrupole massspectrometer (USA) equipped with an electrospray ion source (ESI) operating in negative mode.   Results Intraassay CV values for acetylsalicylic acid were 8% and 6% for 0.8 and 100 µg/L, respectively.   Discussion The narrow therapeutic range of these drugs are of importance to be analyzed at critical concentrations. This method has capability to determine these levels.   Conclusion We can conclude that the developed method can be useful for clinical studies and routine therapeutic drug monitoring with the desired precision and accuracy.   Keywords Salicylic toxicity, tandem mass, high performance, chromatography.   Acknowledgments: No conflict of interest

🔖

Bu Makaleye Atıf Yap

Abusoglu, S., Unlu, A., Sivrikaya, A. (2017). FAST DETECTION OF ACETYLSALICYLIC ACID BY LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY(LC-MSMS). The Turkish Journal Of Occupational / Environmental Medicine and Safety, Cilt: 2 Sayı: 1(4), 30–30. https://ajindex.com/articles/1659564

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. Sedat Abusoglu*, Ali Unlu, Abdullah Sivrikaya Department of Biochemistry, SelcukUniversity Faculty of Medicine, Konya, Turkey