Dergiler / Engineering Sciences / 2026 / Cilt: 5 Sayı: 2

THERMO-ECONOMYC OPTYMYZATYON OF A VAPOUR COMPRESSED REFRYGERATYON SYSTEM USYNG ALTERNATYVE REFRYGERANTS

BUHAR SIKI?TIRMALI SO?UTMA SYSTEMYNDE ALTERNATYF SO?UTUCU AKI?KAN YÇYN TERMOEKONOMYK OPTYMYZASYON

Sayfa
381–398
Yayın Tarihi
2010-03-01
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Keywords: Thermo-economy, optimization, alternative refrigerants (R410A and R407C)

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:This study deals with the thermo-economic optimization of superheating and sub-cooling heat exchangers in vapor compressed refrigeration system.
📊
Temel Bulgular & Veri:Using for R22 and its alternative refrigerants (R410A and R407C), the temperature of condenser at the interval of (35°C – 55°C) and temperature of evaporator at the interval of (-10°C – 10°C) have been obtained from the calculation process.
💡
Sonuç & Katkı:Keywords: Thermo-economy, optimization, alternative refrigerants (R410A and R407C)
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:THERMOECONOMY · OPTIMIZATION · ALTERNATIVE REFRIGERANTS

Özet

This study deals with the thermo-economic optimization of superheating and sub-cooling heat exchangers in vapor compressed refrigeration system. Using for R22 and its alternative refrigerants (R410A and R407C), the temperature of condenser at the interval of (35°C – 55°C) and temperature of evaporator at the interval of (-10°C – 10°C) have been obtained from the calculation process. The second law analysis of refrigeration system is carried out and then the whole system is optimized by thermo-economically. As a result of calculations, optimum superheating and sub-cooling temperatures of heat exchangers areas corresponding to these temperatures are obtained. Keywords: Thermo-economy, optimization, alternative refrigerants (R410A and R407C)

Abstract

Bu çaly?mada, buhar syky?tyrmaly bir so?utma sisteminde a?yry so?utma ve a?yry kyzdyrma ysy de?i?tiricilerinin termo-ekonomik optimizasyonu yapylmy?tyr. So?utucu aky?kan R22 ve onun alternatifleri olan R410A ve R407C için kondenser sycaklyk araly?y (35°C – 55°C) ve evaporatör sycaklyk araly?y (-10°C – 10°C) alynarak hesaplamalar yapylmy?tyr. So?utma sisteminin II. Kanun analizi yapylarak tüm sistem termo-ekonomik olarak optimize edilmi?tir. Sonuç olarak, verilen sycaklyk aralyklaryna göre optimum a?yry kyzdyrma ve a?yry so?utma ysy de?i?tiricileri alanlary hesaplanmy?tyr.

🔖

Bu Makaleye Atıf Yap

Özkaymak, M., Acar, B., Özkaya, M. G. (2010). THERMO-ECONOMYC OPTYMYZATYON OF A VAPOUR COMPRESSED REFRYGERATYON SYSTEM USYNG ALTERNATYVE REFRYGERANTS. Engineering Sciences, Cilt: 5 Sayı: 2, 381–398. https://doi.org/10.12739/nwsaes.v5i2.5000067101

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...