Dergiler / Molecular Oncologic Imaging / 2024 / Volume: 4 Issue: 3

Intra-Interobserver Variability in Myocardial Perfusion and Function Interpretation and Reproducibility of QGS/QPS Software

Duygu Tokbay(ANTALYA EDUCATİON AND RESEASRCH HOSPİTAL)0000-0002-0542-254X
İrem Erim(BAyındır hospital)0009-0006-9284-2206
Sayfa
—
Yayın Tarihi
2025-01-14
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

QPS/QGS software quantitative perfusion and left ventricular ejection fraction (LVEF) values showed high repeatability.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Aim: To assess three different level experienced nuclear medicine specialists’ intra- and interobserver variability of semiquantitative visual interpretations of left ventricular (LV) myocardial perfusion, wall motion (WM), and wall thickening (WT) in gated myocardial perfusion single- photon emission tomography (gMPS), and to compare the compatibility between the observers’ and coronary angiography (CAG) reports.
📊
Temel Bulgular & Veri:Methods: A 5-point perfusion scale, a 6-point scale for WM, and a 4-point scale for WT were used to score each segment.
💡
Sonuç & Katkı:QPS/QGS software quantitative perfusion and left ventricular ejection fraction (LVEF) values showed high repeatability.
🔬Tür:Research Article
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Gated myocardial perfusion single-photon emission tomography · left ventricular myocardial perfusion · wall motion

Abstract

Aim: To assess three different level experienced nuclear medicine specialists’ intra- and interobserver variability of semiquantitative visual interpretations of left ventricular (LV) myocardial perfusion, wall motion (WM), and wall thickening (WT) in gated myocardial perfusion single- photon emission tomography (gMPS), and to compare the compatibility between the observers’ and coronary angiography (CAG) reports. Methods: A 5-point perfusion scale, a 6-point scale for WM, and a 4-point scale for WT were used to score each segment. The images were interpreted 3 times at least one-month intervals separately by 3 observers. Subsequently, the visual semiquantitative summed scores for stress (SSS) and rest (SRS) were calculated by summing the respective segmental perfusion scores. Summed difference score (SDS) was also calculated as the difference between SSS and SRS. Both visual semiquantitative WM and WT scores were calculated from the stress images by summing all corresponding segmental scores. Results: Intraobserver agreement in the evaluation of global perfusion was statistically significant (71.9-100 %). There was a significant agreement in all LAD-SSS, Cx-SSS, ve RCA-SSS interpretations. There was good agreement between 3 readings of 3 observers' (p=0.0). Due to the high interobserver agreement levels in the global evaluation, the mean values of the 1. and the 2. interpretations (mean 1.-2. int.) were calculated and regional comparisons were made with this new value and the 3. interpretation. There was a a significant agreement in 3 of the regional SSS interpretations. Although lowest agreement rates were calculated in LAD artery territory, the agreement levels were statistically, and highly significant in all territories. In both Cx and RCA territories, the agreement levels were statistically significant (p<0.05). Conclusion: The interobserver and intraobserver agreement levels of perfusion interpretations were significant both in the global and regional base. There was a significant agreement between the visual interpretations and CAG results, especially in the Cx and RCA artery territories. The interobserver and intraobserver agreements were higher in WM scores than wall thickness scores. QPS/QGS software quantitative perfusion and left ventricular ejection fraction (LVEF) values showed high repeatability.

🔖

Bu Makaleye Atıf Yap

Tokbay, D., Öztürk, E., Erim, İ. (2025). Intra-Interobserver Variability in Myocardial Perfusion and Function Interpretation and Reproducibility of QGS/QPS Software. Molecular Oncologic Imaging, Volume: 4 Issue: 3. https://doi.org/10.71286/moi.1596275

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (23)

  1. Matsuo, S., Nakajima, K., & Kinuya, S. (2010). Clinical use of nuclear cardiology in the assessment of heart failure. World journal of cardiology, 2(10), 344–356. https://doi.org/10.4330/wjc.v2.i10.344
  2. Berman, D. S., Kiat, H., Friedman, J. D., Wang, F. P., van Train, K., Matzer, L., Maddahi, J., & Germano, G. (1993). Separate acquisition rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: a clinical validation study. Journal of the American College of Cardiology, 22(5), 1455–1464. https://doi.org/10.1016/0735-1097(93)90557-h
  3. Berman, D. S., Abidov, A., Kang, X., Hayes, S. W., Friedman, J. D., Sciammarella, M. G., Cohen, I., Gerlach, J., Waechter, P. B., Germano, G., & Hachamovitch, R. (2004). Prognostic validation of a 17-segment score derived from a 20-segment score for myocardial perfusion SPECT interpretation. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 11(4), 414–423. https://doi.org/10.1016/j.nuclcard.2004.03.033 Golub, R. J., Ahlberg, A. W., McClellan, J. R., Herman, S. D., Travin, M. I., Mather, J. F., Aitken, P. W., Baron, J. I., & Heller, G. V. (1999). Interpretive reproducibility of stress Tc-99m sestamibi tomographic myocardial perfusion imaging. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 6(3), 257–269. https://doi.org/10.1016/s1071-3581(99)90037-5
  4. Mehrotra, P., Labib, S. B., & Schick, E. C. (2012). Differential effects of dobutamine versus treadmill exercise on left ventricular volume and wall stress. Journal of the American Society of Echocardiography: official publication of the American Society of Echocardiography, 25(8), 911–918. https://doi.org/10.1016/j.echo.2012.05.002
  5. Hara, M., Monzen, H., Futai, R., Inagaki, K., Shimoyama, H., Morikawa, M., Tomioka, N., Konishi, T., Watanabe, Y., Yuki, R., Kobayashi, H., & Hirose, K. (2008). Reduction of infracardiac intestinal activity by a small amount of soda water in technetium-99m tetrofosmin myocardial perfusion scintigraphy with adenosine stress. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 15(2), 241–245. https://doi.org/10.1016/j.nuclcard.2007.09.029
  6. Xu, Y., Hayes, S., Ali, I., Ruddy, T. D., Wells, R. G., Berman, D. S., Germano, G., & Slomka, P. J. (2010). Automatic and visual reproducibility of perfusion and function measures for myocardial perfusion SPECT. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 17(6), 1050–1057. https://doi.org/10.1007/s12350-010-9297-0
  7. Konno, M., Morita, K., Adachi, I., Ito, Y., Kohya, T., Kitabatake, A., Tsukamoto, E., & Tamaki, N. (2001). Quantitative analysis of regional wall motion and thickening by quantitative gated SPECT: comparison with visual analysis. Clinical nuclear medicine, 26(3), 202–207. https://doi.org/10.1097/00003072-200103000-00004
  8. Germano, G., Erel, J., Lewin, H., Kavanagh, P. B., & Berman, D. S. (1997). Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. Journal of the American College of Cardiology, 30(5), 1360–1367. https://doi.org/10.1016/s0735-1097(97)00276-3
  9. Hendel, R. C., Parker, M. A., Wackers, F. J., Rigo, P., Lahiri, A., & Zaret, B. L. (1994). Reduced variability of interpretation and improved image quality with a technetium 99m myocardial perfusion agent: comparison of thallium 201 and technetium 99m-labeled tetrofosmin. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 1(6), 509–514. https://doi.org/10.1007/BF02939973
  10. Berman, D., Germano, G., Lewin, H., Kang, X., Kavanagh, P. B., Tapnio, P., Harris, M., & Friedman, J. (1998). Comparison of post-stress ejection fraction and relative left ventricular volumes by automatic analysis of gated myocardial perfusion single-photon emission computed tomography acquired in the supine and prone positions. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 5(1), 40–47. https://doi.org/10.1016/s1071-3581(98)80009-3
  11. Itti, E., Rosso, J., Damien, P., Auffret, M., Thirion, J. P., & Meignan, M. (2001). Assessment of ejection fraction with Tl-201 gated SPECT in myocardial infarction: Precision in a rest-redistribution study and accuracy versus planar angiography. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 8(1), 31–39. https://doi.org/10.1067/mnc.2001.109863
  12. Kumita, S., Cho, K., Nakajo, H., Toba, M., Kijima, T., Mizumura, S., Oshina, T., Kumazaki, T., Sano, J., Sakurai, K., & Munakata, K. (2001). Serial assessment of left ventricular function during dobutamine stress by means of electrocardiography-gated myocardial SPECT: combination with dual-isotope myocardial perfusion SPECT for detection of ischemic heart disease. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 8(2), 152–157. https://doi.org/10.1067/mnc.2001.112137
  13. Hedeer, F., Palmer, J., Arheden, H., & Ugander, M. (2010). Gated myocardial perfusion SPECT underestimates left ventricular volumes and shows high variability compared to cardiac magnetic resonance imaging -- a comparison of four different commercial automated software packages. BMC medical imaging, 10, 10. https://doi.org/10.1186/1471-2342-10-10
  14. Miernik, S., Kaźmierczak-Dziuk, A., Kamiński, G., & Dziuk, M. (2012). The prognostic value of myocardial perfusion scintigraphy compared to coronary angiography in women with positive stress test results. Nuclear medicine review. Central & Eastern Europe, 15(1), 31–38. https://doi.org/10.5603/nmr-18728
  15. Calé R, Almeida M, Rebocho MJ, Aguiar C, Sousa P, Brito J, et al. The value of routine intracoronary ultrasound to assess coronary artery disease in cardiac allograft recipients. [Article in English, Portuguese]. Rev Port Cardiol. 2010;29(2):231-41.
  16. Berman, D. S., Abidov, A., Kang, X., Hayes, S. W., Friedman, J. D., Sciammarella, M. G., Cohen, I., Gerlach, J., Waechter, P. B., Germano, G., & Hachamovitch, R. (2004). Prognostic validation of a 17-segment score derived from a 20-segment score for myocardial perfusion SPECT interpretation. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 11(4), 414–423. https://doi.org/10.1016/j.nuclcard.2004.03.033 Golub, R. J., Ahlberg, A. W., McClellan, J. R., Herman, S. D., Travin, M. I., Mather, J. F., Aitken, P. W., Baron, J. I., & Heller, G. V. (1999). Interpretive reproducibility of stress Tc-99m sestamibi tomographic myocardial perfusion imaging. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 6(3), 257–269. https://doi.org/10.1016/s1071-3581(99)90037-5
  17. Mehrotra, P., Labib, S. B., & Schick, E. C. (2012). Differential effects of dobutamine versus treadmill exercise on left ventricular volume and wall stress. Journal of the American Society of Echocardiography: official publication of the American Society of Echocardiography, 25(8), 911–918. https://doi.org/10.1016/j.echo.2012.05.002
  18. Hara, M., Monzen, H., Futai, R., Inagaki, K., Shimoyama, H., Morikawa, M., Tomioka, N., Konishi, T., Watanabe, Y., Yuki, R., Kobayashi, H., & Hirose, K. (2008). Reduction of infracardiac intestinal activity by a small amount of soda water in technetium-99m tetrofosmin myocardial perfusion scintigraphy with adenosine stress. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 15(2), 241–245. https://doi.org/10.1016/j.nuclcard.2007.09.029
  19. Xu, Y., Hayes, S., Ali, I., Ruddy, T. D., Wells, R. G., Berman, D. S., Germano, G., & Slomka, P. J. (2010). Automatic and visual reproducibility of perfusion and function measures for myocardial perfusion SPECT. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 17(6), 1050–1057. https://doi.org/10.1007/s12350-010-9297-0
  20. Hendel, R. C., Parker, M. A., Wackers, F. J., Rigo, P., Lahiri, A., & Zaret, B. L. (1994). Reduced variability of interpretation and improved image quality with a technetium 99m myocardial perfusion agent: comparison of thallium 201 and technetium 99m-labeled tetrofosmin. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 1(6), 509–514. https://doi.org/10.1007/BF02939973
  21. Berman, D., Germano, G., Lewin, H., Kang, X., Kavanagh, P. B., Tapnio, P., Harris, M., & Friedman, J. (1998). Comparison of post-stress ejection fraction and relative left ventricular volumes by automatic analysis of gated myocardial perfusion single-photon emission computed tomography acquired in the supine and prone positions. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 5(1), 40–47. https://doi.org/10.1016/s1071-3581(98)80009-3
  22. Itti, E., Rosso, J., Damien, P., Auffret, M., Thirion, J. P., & Meignan, M. (2001). Assessment of ejection fraction with Tl-201 gated SPECT in myocardial infarction: Precision in a rest-redistribution study and accuracy versus planar angiography. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 8(1), 31–39. https://doi.org/10.1067/mnc.2001.109863
  23. Kumita, S., Cho, K., Nakajo, H., Toba, M., Kijima, T., Mizumura, S., Oshina, T., Kumazaki, T., Sano, J., Sakurai, K., & Munakata, K. (2001). Serial assessment of left ventricular function during dobutamine stress by means of electrocardiography-gated myocardial SPECT: combination with dual-isotope myocardial perfusion SPECT for detection of ischemic heart disease. Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology, 8(2), 152–157. https://doi.org/10.1067/mnc.2001.112137