Comparison of Anterior Segment Parameters Between Phakic and Pseudophakic Eyes of Subjects with Emmetropia and Degenerative Myopia

Sayfa
92–98
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

However, most of the specular microscope measurements did not show a signifi cant difference in degenerative myopia.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Purpose: To compare and assess anterior segment measurements including corneal endothelial parameters in phakic and pseudophakic patients with degenerative myopia and emmetropia participants.
📊
Temel Bulgular & Veri:Materials and Methods: The individuals were divided into two main groups of Group 1 (control group) and Group 2 (study group).Emmetropic, mild myopic and/or hypermetropic patients were enrolled in Group 1.
💡
Sonuç & Katkı:However, most of the specular microscope measurements did not show a signifi cant difference in degenerative myopia.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Purpose: To compare and assess anterior segment measurements including corneal endothelial parameters in phakic and pseudophakic patients with degenerative myopia and emmetropia participants. Materials and Methods: The individuals were divided into two main groups of Group 1 (control group) and Group 2 (study group).Emmetropic, mild myopic and/or hypermetropic patients were enrolled in Group 1. Degenerative Myopic Patients Were Enrolled in Group 2. Group 1 and 2 were composed of phakic (Group 1A, Group 2A) n pseudophakic (Group 1B, Group 2B) eyes. Corneal endothelial cell density (CD), the coeffi cient of variation of cell size (CV), hexagonality (HEX) and central corneal thickness (CCT) were of the parameters measured by the specular microscope. Anterior chamber depth (ACD), white to white (WTW) diameter and axial length (AXL) were the parameters measured by optical biometer. Results: The mean ACD was 3.45±0.55 mm and 3.74±0.61 mm (p=0.005), and the mean AXL was 23.3±0.9 mm and 28.6±5.3 mm (p<0.001) in the control and study group, respectively. Mean BCVA values were worse and mean SE values were higher in degenerative myopic eyes than in emmetropic eyes of both phakic and pseudophakic subjects. Mean ACD was higher in degenerative myopia. Mean K2 was different between Group 1B and Group 2B (p=0.003). Conclusion: Degenerative myopia has high SE, ACD and AXL values. However, most of the specular microscope measurements did not show a signifi cant difference in degenerative myopia.

🔖

Bu Makaleye Atıf Yap

DEMIR, M., AKPOLAT, C., ARSLAN, G. D., SENDUL, S. Y., GUVEN, D. (2020). Comparison of Anterior Segment Parameters Between Phakic and Pseudophakic Eyes of Subjects with Emmetropia and Degenerative Myopia. Glokom Katarakt, Cilt: 29 - Sayı: 2, 92–98. https://ajindex.com/articles/157137

Kaynakça (16)

  1. Ng DS, Cheung CY, Luk FO, et al. Advances of optical coherence tomography in myopia and pathologic myopia. Eye (Lond). 2016;30:901-16
  2. Komai Y, Ushiki T. The three-dimensional organization of collagen fi brils in the human cornea and sclera. Invest Ophthalmol Vis Sci. 1991;32:2244-58
  3. Delshad S, Chun JM. Corneal endothelial cell density and morphology in low and moderate myopic Chinese eyes. Int J Ophthalmol. 2013;18;6:467-70
  4. Holden BA, Fricke TR, Wilson DA, et al. Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050. Ophthalmology. 2016;123:1036–42
  5. Pan CW, Boey PY, Cheng CY, et al. Myopia, axial length, and age-related cataract: the Singapore Malay eye study. Invest Ophthalmol Vis Sci 2013;54: 4498-502
  6. Pron G, Ieraci L, Kaulback K. Medical Advisory Secretariat, Health Quality Ontario. Collagen cross-linking using ribofl avin and ultraviolet-a for corneal thinning disorders: an evidence-based analysis. Ont Health Technol Assess Ser. 2011;11:1–89
  7. Sheng H, Bullimore MA. Factors affecting corneal endothelial morphology. Cornea. 2007;26:520-5
  8. Islam QU, Saeed MK, Mehboob MA. Age related changes in corneal morphological characteristics of healthy Pakistani eyes. Saudi J Ophthalmol. 2017;31:86-90
  9. Bao F, Wang Q, Cheng S, et al. Comparison and evaluation of central corneal thickness using 2 new noncontact specular microscopes and conventional pachymetry devices. Cornea. 2014;33:576–81
  10. Luft N, Hirnschall N, Schuschitz S, et al. Comparison of 4 specular microscopes in healthy eyes and eyes with cornea guttata or corneal grafts. Cornea. 2015;34:381-6
  11. Kartal B, Kandemir B, Akmaz B, et al. Specular Microscopy Data of Cornea Bank Donors at Kartal Training and Research Hospital. Turk J Ophthalmol. 2014;44:190-5
  12. Natung T, Shullai W, Nongrum B, et al. Ocular biometry characteristics and corneal astigmatisms in cataract surgery candidates at a tertiary care center in North-East India. Indian J Ophthalmol. 2019;67:1417-23
  13. Çankaya C, Doğanay S. Intra Ocular Lens Power Calculation and Optic Biometry. Review. Glo-Kat. 2011;6:129-31
  14. Anbar M, Ammar H, Mahmoud RA. Corneal Endothelial Morphology in Children with Type 1 Diabetes. J Diabetes Res. 2016;2016:7319047
  15. Hoffer KJ, Savini G. Comparison of AL-Scan and IOLMaster 500 Partial Coherence Interferometry Optical Biometers. J Refract Surg. 2016;32:694-8
  16. Kumar A, Chawla R, Kumawat D. Insight into high myopia and the macula. Indian J O