Dergiler / Electrica / 2018 / Cilt: 18 - Sayı: 1

A Molecularly Imprinted Polymer Based Biosensor for Electrochemical Impedance Spectroscopic Analysis

Sayfa
39–44
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Thus, MIP-based small-molecule biosensor prototypes can be promising economical replacements over other expensive sensors.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:A molecularly imprinted polymer (MIP)-based impedimetric biosensor was developed for the electrochemical analysis of low-weight biological molecules.
📊
Temel Bulgular & Veri:The electrode modification and performance were evaluated using cyclic voltammetry and electrochemical impedance spectroscopy.
💡
Sonuç & Katkı:Thus, MIP-based small-molecule biosensor prototypes can be promising economical replacements over other expensive sensors.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

A molecularly imprinted polymer (MIP)-based impedimetric biosensor was developed for the electrochemical analysis of low-weight biological molecules. Synthetic polymeric matrices with specific and selective recognition sites, which are complementary to the shapes and sizes of the functional groups of analytes, can be prepared using the molecular imprinting method. In this study, a small molecule, tris(hydroxymethyl)aminomethane (TRIS), was used to coat a graphite pencil tip with a TRIS-containing polyacrylamide gel to fabricate a working electrode. The electrode modification and performance were evaluated using cyclic voltammetry and electrochemical impedance spectroscopy. The electrochemical properties of the modified electrodes were observed using an electrochemical cell comprising a Ag/AgCl reference electrode, a Pt wire as the counter electrode, and a pencil graphite tip as the working electrode using a redox-phosphate buffer solution with different concentrations of TRIS and Ethylenediaminetetraacetic acid (EDTA). The I–V and impedance performance of the chemically modified graphite pencil-tip electrodes exhibited decreased conductance and increased impedance correlating with the increase in TRIS concentration. Thus, MIP-based small-molecule biosensor prototypes can be promising economical replacements over other expensive sensors.

🔖

Bu Makaleye Atıf Yap

UTKU, F. S., ÖZDEMİR, O. E., BAKAY, M. S. (2018). A Molecularly Imprinted Polymer Based Biosensor for Electrochemical Impedance Spectroscopic Analysis. Electrica, Cilt: 18 - Sayı: 1, 39–44. https://ajindex.com/articles/153726

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (4)

  1. A. Turner, I. Karube, G. S. Wilson, “Biosensors: Fundamentals and Applications”, Oxford University Press,
  2. Oxford, U.K., 1987. F. G. Banica, ed., “Chemical Sensors and Biosensors: Fundamentals and Applications”, John Wiley & Sons, Hoboken, New Jersey, U.S.A., 2012. [CrossRef] B. R. Eggins, “Chemical Sensors and Biosensors”, John Wiley & Sons, Hoboken, New Jersey, U.S.A., 2002.
  3. S. Yan, Y. Fang, Z. Gao, “Quartz crystal microbalance for the determination of daminozide using molecularly imprinted polymers as recognition element”, Biosensors and Bioelectronics, vol. 22, no. 6, pp. 1087-1091, Apr, 2007. [CrossRef] C. Alexander, H. S. Andersson, L. I. Andersson, R. J. Ansell, N. Kirsch, I. A. Nicholls, and M. J. Whitcombe, “Molecular imprinting science and technology: a survey of the literature for the years up to and including 2003”, J Molecular Recognition, vol. 19, no. 2, pp. 106-180, Jan, 2006. [CrossRef] W. Li and S. Li, “Oligomers-Polymer Composites-Molecular Imprinting”, Springer, Berlin-Heidelberg, Germany, 2006.
  4. G. Guan, B. Liu, Z. Wang, Z. Zhang, “Imprinting of molecular recognition sites on nanostructures and its applications in chemosensors”, Sensors, vol. 8, no. 12, pp. 8291-8320, Dec, 2008. [CrossRef] L. Ye and K. Haupt, “Molecularly imprinted polymers as antibody and receptor mimics for assays, sensors and drug discovery”, Analytical and Bioanalytical Chemistry, vol. 378, no. 8, pp. 1887-1897, Jan, 2004. [CrossRef] A. Bossi, F. Bonini, A. P. F Turner and S. A. Piletsky, “Molecularly imprinted polymers for the recognition of proteins: the state of the art”, Biosensors and Bioelectronics, vol. 22, no. 6, pp. 1131-1137, Jan, 2007. [CrossRef] E. Caro, N. Masqué, R. M. Marcé, F. Borrull, P. A. Cormack, and D. C. Sherrington, “Non-covalent and semi-covalent molecularly imprinted polymers for selective on-line solid-phase extraction of 4-nitrophenol from water samples”, J Chromatography A, vol. 963, no. 1, pp. 169-178, July, 2002. [CrossRef] G. Vasapollo, R. D. Sole, L. Mergola, M. R. Lazzoi, A. Scardino, S. Scorrano, and G. Mele, “Molecularly imprinted polymers: present and future prospective”, Int. J Mol Sci, vol. 12, no. 9, pp. 5908-5945, Sept 14, 2011. [CrossRef] G. Gomori, “Preparation of Buffers for Use in Enzyme Studies”, Methods Enzymol., vol. 1, pp. 138-146, 1955. [CrossRef] E. Barsoukov and J. R. Macdonald, “Impedance spectroscopy: theory, experiment, and applications”, John Wiley & Sons, Hoboken, New Jersey, U.S.A., 2005. [CrossRef] B. Ozcan, B.