Dergiler / Eastern Journal of Medicine / 2020 / Cilt: 25 - Sayı: 2

Hemodynamic Monitoring Using A Pulse Counter Vigileo Flotrac Cardiac Output System In Transapical Off-Pump Minimally Invasive Mitral Valve Repair

Sayfa
177–183
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Increased cardiac output measurement after placement of the neochordaes and elimination of insufficiency have emerged as indications of early hemodynamic recovery

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The aim of this study was to present our anesthetic management and early hemodynamic recovery after transapical off-pump neochords implantation.
📊
Temel Bulgular & Veri:The perioperative records of 13 patients who underwent mitral valve repair using the Neochord DS1000 system were analyzed.
💡
Sonuç & Katkı:Increased cardiac output measurement after placement of the neochordaes and elimination of insufficiency have emerged as indications of early hemodynamic recovery
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

The aim of this study was to present our anesthetic management and early hemodynamic recovery after transapical off-pump neochords implantation. Observational prospective study. The perioperative records of 13 patients who underwent mitral valve repair using the Neochord DS1000 system were analyzed. Hemodynamic measurements recorded with the Vigileo Flotrac invasive arterial cardiac output system were evaluated. Thirteen patients were included in the study. Transfusions of a total of 2 U of erythrocytes and 11 U of plasma were performed. After Neochord implantation, the mean cardiac output increased at a statistically significant level according to the values measured after induction p = 0.003. Increased cardiac output measurement after placement of the neochordaes and elimination of insufficiency have emerged as indications of early hemodynamic recovery

🔖

Bu Makaleye Atıf Yap

KAPLAN, H. S., KARADENİZ, Ü., KAYA, B., ERDEM, A. F., KARA, İ. (2020). Hemodynamic Monitoring Using A Pulse Counter Vigileo Flotrac Cardiac Output System In Transapical Off-Pump Minimally Invasive Mitral Valve Repair. Eastern Journal of Medicine, Cilt: 25 - Sayı: 2, 177–183. https://ajindex.com/articles/152814

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (11)

  1. Suri RM, Antiel RM, Burkhart HM, Huebner M, Li Z, Eton DT, et al. Quality of life after early mitral valve repair using conventional and robotic approaches. Ann Thorac Surg. 2012 Mar;93(3):761-9.
  2. Nishimura RA, Carabello BA. Hemodynamics in the cardiac catheterization laboratory of the 21st century. Circulation. 2012 May 1;125(17):2138-50.
  3. Samalavicius, R. S., Norkiene, I., Drasutiene, A., Lipnevicius, A., Janusauskas, V., Urbonas, K., et al. (2018) Anesthetic Management and Procedural Outcomes of Patients Undergoing Off-Pump Transapical Implantation of Artificial Chordae to Correct Mitral Regurgitation: Case Series of 76 Patients. Anesthesia & Analgesia, 1;126(3):776-784.
  4. Patzelt J, Zhang Y, Magunia H, Jorbenadze R, Droppa M, Ulrich M, et al (2017) Immediate increase of cardiac output after percutaneous mitral valve repair (PMVR) determined by echocardiographic and invasive parameters: Patzelt: increase of cardiac output after PMVR. International journal of cardiology 1;236:356-62.
  5. Demetrio P, Andrea C, Gianclaudio F, Antonio M, Gino G, Carlo O (2015) Transesophageal echocardiography in NeoChord procedure. Annals of cardiac anaesthesia 18(2):191. Iung B, Baron G, Butchart EG, Delahaye F, Gohlke-Bärwolf C, Levang OW, et al. (2003) A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease. European heart journal 1;24(13):1231-43.
  6. Enriquez-Sarano M, Sundt TM (2010) Early surgery is recommended for mitral regurgitation. Circulation 16;121(6):804-12.
  7. Colli A, Manzan E, Zucchetta F, Bizzotto E, Besola L, Bagozzi L, et al. (2016). Transapical off-pump mitral valve repair with Neochord implantation: early clinical results. International journal of cardiology 1;204:23-8.
  8. Seeburger J, Leontjev S, Neumuth M, Noack T, Höbartner M, Misfeld M, et al. (2011) Trans-apical beating-heart implantation of neo-chordae to mitral valve leaflets: results of an acute animal study. European Journal of Cardio-Thoracic Surgery 1;41(1):173-6.
  9. Bajona P, Katz WE, Daly RC, Zehr KJ, Speziali G (2009) Beating-heart, off-pump mitral valve repair by implantation of artificial chordae tendineae: an acute in vivo animal study. The Journal of thoracic and cardiovascular surgery 1;137(1):188-93.
  10. Colli A, Manzan E, Rucinskas K, Janusauskas V, Zucchetta F, Zakarkaitė D, et al. (2015) Acute safety and efficacy of the NeoChord procedure. Interactive cardiovascular and thoracic surgery 16;20(5):575-81.
  11. Seeburger J, Rinaldi M, Nielsen SL,