Dergiler / Journal of Physical Chemistry and Functional Materials / 2024 / Volume: 7 Issue: 2

Correction:

Correction: Effect of Heat Treatment on Some Thermodynamics Analysis, Crystal and Microstructures of Cu-Al-X (X: Nb, Hf) Shape Memory Alloy

Gonca Ateş(SIRNAK UNIVERSITY, ŞIRNAK VOCATIONAL SCHOOL)0000-0002-9416-342X
Sayfa
—
Yayın Tarihi
2024-12-18
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

And finally, optical images represented that Hafnium (Hf) is more dissolved in the alloy compared to Niobium (Nb).

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Abstract: Heat treatment is an important technique that can improve the properties of shape memory alloys.
📊
Temel Bulgular & Veri:In this study the effect of heat treatment at three different temperatures (973 K, 1073 K and 1173 K) on some thermodynamics parameters, crystal structure, and microstructure of Cu_86 Al_12 Nb_2 and Cu_86 Al_12 Hf_2 (mass %) Shape Memory Alloy has been investigated.
💡
Sonuç & Katkı:And finally, optical images represented that Hafnium (Hf) is more dissolved in the alloy compared to Niobium (Nb).
🔬Tür:Erratum
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Shape memory alloy · Heat Treatment · Microstructures

Abstract

Abstract: Heat treatment is an important technique that can improve the properties of shape memory alloys. In this study the effect of heat treatment at three different temperatures (973 K, 1073 K and 1173 K) on some thermodynamics parameters, crystal structure, and microstructure of Cu_86 Al_12 Nb_2 and Cu_86 Al_12 Hf_2 (mass %) Shape Memory Alloy has been investigated. After heat treatment, the change in the thermal properties of the samples was determined using Differential Scanning calorimetry (DSC). The effect of heat treatment on the crystal and microstructure of the alloy samples were determined at room temperature using X-ray diffraction (XRD), Scanning Electron microscopy (SEM) device. The DSC result showed that in both samples the temperature hysteresis was decreased after heat treatment. Also grain size was decreased by increasing the treatment temperature in both samples. And finally, optical images represented that Hafnium (Hf) is more dissolved in the alloy compared to Niobium (Nb).

🔖

Bu Makaleye Atıf Yap

Öner, E., Ateş, G., Mohammed, S. S., Kanca, M., Kök, M. (2024). Correction:. Journal of Physical Chemistry and Functional Materials, Volume: 7 Issue: 2. https://doi.org/10.54565/jphcfum.1525381

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. empty line between each references