Dergiler / Electrica / 2018 / Cilt: 18 - Sayı: 1

Corona Identification of Impulse Voltage and Current

Sayfa
78–82
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

A feature which is dependent the frequency is not found.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The corona effect in the power system has a dominant role in reducing the efficiency of the high-voltage lines.
📊
Temel Bulgular & Veri:With these graphs, frequency values have been found to provide an important clarification of the insulation performance of electrical equipment for reliable and accurate diagnosis.
💡
Sonuç & Katkı:A feature which is dependent the frequency is not found.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

The corona effect in the power system has a dominant role in reducing the efficiency of the high-voltage lines. In this study, the current and voltage impulses, which are important in corona determination, have been examined in frequecy spectrogram base from test result. The frequency spectrogram graphs have been obtained from the current-time and voltage-time variation by Matlab program. With these graphs, frequency values have been found to provide an important clarification of the insulation performance of electrical equipment for reliable and accurate diagnosis. These values have been observed according to different conditions like pressure, polarity, and insulation ambient. This spectrogram analysis can be used to find the characteristic frequencies and eliminate the disturbance effect. The time between corona steps decrease when Sulphur hexafluoride (SF6) gas pressure is increased. The time of second corona is close to leader's discharge time. Corona starts early when SF6 amount is decreased in gas mixtures. The corona currents are large in the low SF6 gas mixtures, this situation is related to the high insulation of the SF6 gas. A feature which is dependent the frequency is not found.

🔖

Bu Makaleye Atıf Yap

ÖNAL, E. (2018). Corona Identification of Impulse Voltage and Current. Electrica, Cilt: 18 - Sayı: 1, 78–82. https://ajindex.com/articles/150697

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (5)

  1. S. A. Boggs, “Partial discharge: overview and signal generation” IEEE Electrical Insulation Magazine, vol.6, no.4, pp. 33-39, 1990. [CrossRef] A. Maglaras, T. Kousiouris, F. Topalis, D. Katsaros, L. A. Maglaras, K. Giannakopoulou, “Method of controlling corona effects and breakdown voltage of small air gaps stressed by impulse voltages”. arXiv.org, physics, arXiv: 1410.4189, Cornell University library, 2014.
  2. J. Wang, X. Wang, “Lightning Transient Simulation of Transmission Lines Considering the Effects of Frequency Dependent and Impulse Corona” International Conference on Electrical and Control Engineering (ICECE), 2011. [CrossRef] H. Okubo, N. Hayakawa, A. Matsushita, “The relationship between partial discharge current pulse waveforms and physical mechanisms” IEEE Electrical Insulation Magazine, vol. 18, no. 3, pp.38-45, 2014. [CrossRef] J. Kuffel, P. Kuffel, High voltage engineering fundamentals. Newnes. pp. 348-352, 2000.
  3. J. S. Chang, P. A. Lawless, T. Yamamoto, “Corona discharge processes” IEEE Transactions on plasma science, vol. 19, no.6, pp. 11521166. 1991. [CrossRef] L. Wang, S. Liu, M. Wei, H. Xiao, F. Wang. “Time-frequency analysis of nonlinear and non-stationary weak signals of corona discharge”. Journal of Physics: Conference Series. IOP Publishing, vol. 418, no.1, 2013. [CrossRef] L. Zhu, J. Zhu, F. Lü, Y. Liu, Q. Geng, “De-noise of the high frequency corona current with wavelet analysis method” Applied Mechanics and Materials vol. 385, pp. 1394-1397, 2013. [CrossRef] M.B. Priestle. “Non-linear arid Non-stationary Time Series Analysis,” Academic Press, New York, 1988.
  4. S. Tenbohlen, G. Schroder. The Influence of Surface Charge on Lightning Impulse Breakdown of Spacers in SF6 IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 7, No. 2, April 2000. [CrossRef] P. N. Mavroidis, P. N. Mikropoulos, C. A. Stassinopoulos, A. Dodos, P. Zannias, M.B. Priestle. “Discharge Characteristics in short rodplane gaps with Dielectric-Covered Rod under Lightning Impulse Voltages” 17. International Conference on Gas Discharges and Their Applications, 2008.
  5. M. Hasmi, M. Lehtonen, M. Nordman, R. Jabbar, S. Qureshi, “Wavelet based de-noising of on-line PD signals captured by Pearson coil in covered-conductor overhead distribution networks” Journal of Electrical Power Energy Systems, 43 pp. 1185-1192, 2012. [CrossRef] J. Tang, W. Li, Y. Liu, “Blind source separation of mixed PD signals produced by multiple insulation defects in GIS”, IEEE Transaction on P