Dergiler / Electrica / 2019 / Cilt: 19 - Sayı: 2

Design and Modeling of Solar Photovoltaic System Using Seven-Level Packed U-Cell (PUC) Multilevel Inverter and Zeta Converter for Off-Grid Application in India

Sayfa
101–112
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Keywords: Multilevel inverter, packed U-cell inverter, solar PV array, incremental conductance technique.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In the present study, standalone operation of the solar photovoltaic system with storage is evaluated with the recently introduced seven-level packed U-cell (PUC) multilevel inverter.
📊
Temel Bulgular & Veri:The system is modeled in the MATLAB®/Simulink using the Waaree Energies WSM-315 modules to supply a load of 2 kW.
💡
Sonuç & Katkı:Keywords: Multilevel inverter, packed U-cell inverter, solar PV array, incremental conductance technique.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

In the present study, standalone operation of the solar photovoltaic system with storage is evaluated with the recently introduced seven-level packed U-cell (PUC) multilevel inverter. Zeta converter is used to regulate the output voltage of the photovoltaic (PV) array with the help of the MPPT algorithm. Level-shifted modulation scheme is applied for the PUC inverter. The standalone operation is taken into consideration keeping in view the application/ penetration of the solar PV system in remote areas. The Ministry of New and Renewable Energy (MNRE), Government of India has set up the plan to establish the standalone solar PV system for off-grid application in the regions to meet the power requirement of those communities and regions that are difficult to connect with the grid. The climatic condition in the central and western parts of India is conductive for solar PV generation. In contrast to the other well-known inverter topologies, such as neutral point clamped, flying level capacitors, and cascaded H-bridge, among others, PUC inverter requires the least number of switches and capacitors for the same output levels. The system is modeled in the MATLAB®/Simulink using the Waaree Energies WSM-315 modules to supply a load of 2 kW. To optimize the solar PV-based system, incremental conductance optimization technique is used. Keywords: Multilevel inverter, packed U-cell inverter, solar PV array, incremental conductance technique.

🔖

Bu Makaleye Atıf Yap

AZEEM, A. (2019). Design and Modeling of Solar Photovoltaic System Using Seven-Level Packed U-Cell (PUC) Multilevel Inverter and Zeta Converter for Off-Grid Application in India. Electrica, Cilt: 19 - Sayı: 2, 101–112. https://ajindex.com/articles/149932

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. U. Akram, M. Khalid, S. Shafiq, “Optimal sizing of a wind/solar/battery hybrid grid-connected microgrid system,” IET Renew. Power Gener., vol. 12, no. 1, pp. 72-80, Jan. 2018.
  2. M. Nasir, S. Iqbal, H. A. Khan, “Optimal Planning and Design of Low-Voltage Low-Power Solar DC Microgrids,” IEEE Trans. Power Syst., vol. 33, no. 3, pp. 2919-2928, May 2018.
  3. A. Sarwar, M. S. J. Asghar, “Multilevel converter topology for solar PV based grid-tie inverters,” 2010 IEEE Int. Energy Conf. Exhib. Energy Con, pp. 501-506, 2010. J. Rodríguez, J. S. Lai, F. Z. Peng, “Multilevel inverters: A survey of topologies, controls, and applications,” IEEE Trans. Ind. Electron., vol. 49, no. 4, pp. 724-738, 2002.
  4. J. Cheng, CEng, CEM, CEA, and CMVP, “IEEE Standard 519-2014,” Schneider Electr., p. 50, 2014.
  5. H. Vahedi, A. A. Shojaei, L. Dessaint, K. Al-haddad, “Reduced DC Link Voltage Active Power Filter Using Modified PUC5 Converter,” IEEE Trans. Power Electron., vol. 33, no. 2, pp. 943-947, 2017.
  6. M. Tariq, M. T. Iqbal, M. Meraj, A. Iqbal, A. I. Maswood, C. Bharatiraja, “Design of a Proportional Resonant Controller for Packed U Cell 5 Level Inverter for Grid-Connected Applications,” pp. 3-8, 2016.
  7. H. Vahedi, H. Y. Kanaan, K. Al-Haddad, “PUC converter review: Topology, control and applications,” IECON 2015 - 41st Annu. Conf. IEEE Ind. Electron. Soc., pp. 4334-4339, 2015.
  8. H. Vahedi, K. Al-Haddad, “Real-time implementation of a seven-level packed U-cell inverter with a low-switching-frequency voltage regulator,” IEEE Trans. Power Electron., vol. 31, no. 8, pp. 5967-5973, 2016.
  9. A. H. El Khateb, N. A. Rahim, S. Member, J. Selvaraj, B. W. Williams, “DC-to-DC Converter With Low Input Current Ripple for Maximum Photovoltaic Power Extraction,” IEEE Trans. Ind. Electron., vol. 62, no. 4, pp. 2246-2256, 2015.
  10. S. Singh, B. Singh, G. Bhuvaneswari, V. Bist, “Power factor corrected zeta converter based improved power quality switched mode power supply,” IEEE Trans. Ind. Electron., vol. 62, no. 9, pp. 54225433, 2015.
  11. R. Kumar, B. Singh, “BLDC Motor-Driven Solar PV Array-Fed Water Pumping System Employing Zeta Converter,” IEEE Trans. Ind. Appl., vol. 52, no. 3, pp. 2315-2322, 2016.
  12. H. Vahedi, P. A. Labbé, K. Al-Haddad, “Sensor-Less Five-Level Packed U-Cell (PUC5) Inverter Operating in Stand-Alone and Grid-Connected Modes,” IEEE Trans. Ind. Informatics, vol. 12, no. 1, pp. 361-370, 2016.