According to the results obtained, it has been determined that the designed structure is safe.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:This study covers the design of the 155 m3 water tank, which is intended to be established in Tersan Shipyard and to be used for the treatment plant, to meet the needs, and the analysis and verification of the design.
📊
Temel Bulgular & Veri:In order for our water tank design to be considered safe, the result of the analysis should be below the maximum Von Mises Stress value occurring in the structure, below 241.68 MPa.
💡
Sonuç & Katkı:According to the results obtained, it has been determined that the designed structure is safe.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Earthquake factor · Strain in silos · Wind factor in design

Abstract

This study covers the design of the 155 m3 water tank, which is intended to be established in Tersan Shipyard and to be used for the treatment plant, to meet the needs, and the analysis and verification of the design. First of all, the needs were determined and then the solution steps to meet these determinations were determined. The three-dimensional design of the tank, whose material, dimensions and shape were determined, was carried out. In addition, the places where this tank will be fixed were selected and the analysis was carried out in this part by applying the necessary forces to the structure. It was designed using Rhinoceros, a design program, and then Autodesk Nastran finite element analysis program was used. In order for our water tank design to be considered safe, the result of the analysis should be below the maximum Von Mises Stress value occurring in the structure, below 241.68 MPa. Afterwards, the Nastran simulation module was run and as a result of the simulation, Von Mises Stress values of maximum 46.71 MPa and displacement values of maximum 2.136 mm were reached. According to the results obtained, it has been determined that the designed structure is safe.

🔖

Bu Makaleye Atıf Yap

Ozhan, S. D. (2023). Vertical Water Silo Design and Analysis. International Journal of Computational and Experimental Science and Engineering, Cilt: 9 Sayı: 3, 313–319. https://ajindex.com/articles/1494018

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (10)

  1. Çelik A.İ., Akgül T., Apay A.C., Yurtsever A., (2018). Stress and Buckling Analysis of Cylindrical Steel Water Tanks under Seismic Loading. Sürdürülebilir Mühendislik Uygulamaları ve Teknolojik Gelişmeler Dergisi, 1(2);55-66
  2. Alemdar Bayraktar, Barış Sevim, Ahmet Can Altunışık, Temel Türker. (2010). Effect of the model updating on the earthquake behavior of steel storage tanks. Journal of Constructional Steel Research, 66;462-468
  3. Jacobsen, L.S., (1949): Impulsive Hydrodynamics of Fluid Inside a Cylindrical Tank and of a Fluid Surrounding a Cylindrical Pier, Bulletin of the Seismological Society of America, 39;189-204.
  4. Graham, E.W., and Rodriguez, A.M., (1952). The Characteristics of Fuel Motion Which Affect Airplane Dynamics, Journal of Applied Mechanics 19;381-388.
  5. Housner, G., 1957: Dynamic Pressure on Accelerated Fluid Containers, Bulletin of the Seismological Society of America, 47;15-35. 103
  6. Hanson, R.D., 1973: Behavior of Liquid Storage Tanks, Report, National Academy of Sciences, Washington D.C., pp. 331-339.
  7. I. T. Avval, "Dynanic response of concrete rectangular liquid tanks in three-dimensional space", Ph. D. thesis, Ryerson University, Toronto, Canada, 2012
  8. Ünal A., 2012, TDY – 2007’ ye Göre Tasarlanmamış Betonarme Çerçevelerin Düzlem Dışı Perde Duvarla Güçlendirilmesi, Yüksek Lisans Tezi, Selçuk Üniversitesi, Fen Bilimleri Enstitüsü, Konya
  9. Özmen, Y. ve Baydar, E., (2016). Experimental Investigation of Wind Pressure Fields on Buildings with Gabled Roofs Having Different Pitch Angles, Journal of Thermal Science and Technology, 36 (2); 7- 17
  10. İ.Genç, "Designing and Analysis Phases of Four Elements (Master's Thesis)," Atatürk University, 2007.