Dergiler / Eastern Anatolian Journal of Science / 2018 / Volume: 4 Issue: 2

Experimental Study On Compressive Strength, Ultrasonic Pulse Velocity And Water Content Of Concrete At Early Ages After A 28 Day Curing Period

Tahir Serkan Irmak(KOCAELİ ÜNİVERSİTESİ, MÜHENDİSLİK FAKÜLTESİ)
Sayfa
—
Yayın Tarihi
2018-11-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

A clear relationship was found between (UCS) and (ω) with (UPV) over the 12 week period. (UCS), (UPV) and (ω) of concrete increase rapidly in the initial 6 weeks after curing period and then reach about a constant value.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Concrete is most widely used as a building material.
📊
Temel Bulgular & Veri:Although the characteristic strength of the concrete has reached 99% in 28 days of curing time, still concrete continues to gain strength over long period since the hydration process is not confined up to this certain period which is long-lasting process.
💡
Sonuç & Katkı:A clear relationship was found between (UCS) and (ω) with (UPV) over the 12 week period. (UCS), (UPV) and (ω) of concrete increase rapidly in the initial 6 weeks after curing period and then reach about a constant value.
🔬Tür:Research Article
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Concrete · ultrasonic pulse velocity · uniaxial compressive strength

Abstract

Concrete is most widely used as a building material. It is very important to know that the concrete compressive strength was influenced by many factors such as the aggregate type and size, cement type, humidity and water/cement ratio. Although the characteristic strength of the concrete has reached 99% in 28 days of curing time, still concrete continues to gain strength over long period since the hydration process is not confined up to this certain period which is long-lasting process. In this study an attempt was done to determine the variations of ultrasonic pulse velocity (UPV), uniaxial compressive strength (UCS) and water content (ω) of concrete cubes after a 28 day cure period. The concrete cubes for mix design CEM I 42, 5 R grade cement were tested. A clear relationship was found between (UCS) and (ω) with (UPV) over the 12 week period. (UCS), (UPV) and (ω) of concrete increase rapidly in the initial 6 weeks after curing period and then reach about a constant value.

🔖

Bu Makaleye Atıf Yap

Kurtuluş, C., Çiçek, S., Irmak, T. S. (2018). Experimental Study On Compressive Strength, Ultrasonic Pulse Velocity And Water Content Of Concrete At Early Ages After A 28 Day Curing Period. Eastern Anatolian Journal of Science, Volume: 4 Issue: 2. https://ajindex.com/articles/1475692

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (61)

  1. Akkaya Y, Voigt T, Subramaniam KV and Shah SP (2003) Nondestructive measurement of concrete by ultrasonic wave reflection methods, Materials and structures, 36(8):507-514
  2. Albanoa C, Camacho N, Reyes J, Feliu JL, Hernandez M (2005) Influence of scrap rubber addition to Portland I concrete composites: Destructive and non-destructive testing, Composite Structures 71, 439–446
  3. Alimov AG (2007) Improvement of the theoretical foundations of the ultrasonic diagnosis of concrete and reinforced concrete hydrotechnical structures, Hydrotechnical Construction, vol. 2. [In Russian]
  4. Arıoğlu E, Odbay O, Alper H, Apıoğlu B (1994) Birleşik yıkıntısız yöntemle beton dayanımının kestirilmesi için yeni formül ve uygulama sonuçları. Beton Prefabrikasyon, 29, 5-11
  5. ASTM C 597 (2009) Standard Test Method for Pulse Velocity Through Concrete. American Society for Testing and Materials.
  6. Baykof F, and Sigalof Y (1984) Reinforced concrete structure, Moskow: Mier
  7. BSI. Testing concrete. London BS 1881. Parts 5-209, 1970-1998.
  8. Burg, Ronald G (1996) The influence of casting and curing temperature on the properties of fresh and hardened concrete, research and development Bulletin RD113, Portland Cement Association, [Influencia de la temperature durante el colado y el curado en Ias propiedades de concreto frescoy endurecido, Boletin de Investigation y Desarrollo RD113, Asociaci6n de Cemento Portland], Skokie, Illlinois, USA
  9. Carino NJ (1984) Laboratory study of flaw detection in concrete by impact-echo method, In-Situ/Nondestructive Testing of Concrete, Malhotra, V. M., Ed., ACI SP-82, A.C.I., 557
  10. Chang Che-Way and Lien Hung-Sheng (2008) Nondestructive measurement of concrete strength at early ages, department of civil engineering and engineering informatics chung-hua university, Email: [email protected]
  11. Dennis A, Sack DA and Olson LD (1993) Advanced NDT Methods for Concrete Structures, Proceedings of the International Conference on Nondestructive Testing of Concrete in the Infrastructure, sponsored by the Society for Experimental Mechanics, Inc., Dearborn, Michigan
  12. Dzenis VV and Lapsa VH (1972) Ultrasonic testing of hardening concrete. Leningrad: Strojizda (Publishing House for the construction), 1972. [In Russian]
  13. Elvery RH and Ibrahim LAM (1976) Ultrasonic assessment of concrete strength at early ages, Magazine of Concrete Research, December, 181-190
  14. Fadragas CR and Gonzalez MR (2011) Dependence of ultrasonic pulse propagation velocity on free water content in concrete structure under tropical climate conditions, presented at 5th Pan American Conference for NDT, Cancun, Mexico
  15. Gilkey H J (1961) Water/Cement Ratio versus Strength – Another Look. J. Amer. Concr. Inst., Part 2, 58, 1851-1878
  16. Gonnerman HF and Schman HS (1928) Test of plain concrete, Proceedings, Am. Soc. Testing Mats. V.28, Part II, 527
  17. Grosse CU and Reinhardt HW (1994) Continuous ultrasound measurements during setting and hardening of Concrete. Otto Graf Journal 5, 76-98
  18. Guang Ye, K.van Breugel, ALA. Fraaji (2001) Experimental study on ultrasonic pulse velocity evalution of microstructure at cementitius material at early age, Heron, V.46, No.3
  19. Hassan M, Burdet O, Favre R (1995) Ultrasonic measurements and static load tests in bridge evaluation, NDT&E International, 28 (6), 331-337
  20. Hellier C (2003) Handbook of Nondestructive Evaluation: Blacklick, OH: McGraw-Hill Professional Publishing, USA
  21. Jones R (1953) Testing concrete by ultrasonic pulse technique, Proc. Highway Research Board. Vol.32, 258
  22. Jones R (1962) Non-destructive Testing of Concrete. London: Cambridge University Press, 1962
  23. Kaszanyı G (1989) The strength deformation and thermomechanic properties of crushed brick aggragate light-weight concrete, Technical University H-1521 Budapest http:/www.pp.bme.hu/ci/article/download/3917/3022
  24. Keating J, Hannant DJ, Hibbert AP (1989) Correlation between cube strength, ultrasonic, V.19, Issue 5, 715-726
  25. Kheder GF (1999) A two stage procedure for assessment of in situ concrete strength using combined non-destructive testing. Mater Struct, 32(6), 410-417
  26. Kolias S and Georgiou C (2005) The effect of paste volume and of water content on the strength and water absorption of concrete, Cement and Concrete composites, V.27, İssue 2, 211-216
  27. Kolluru G R, Zuk M and Chappell MA (2002) Reduced reproductive effort in male field crickets infested with parasitoid fly larvae. Behavioral Ecology 13: 607-614
  28. Komlos K, Popovics S, Niirnbergeroh T, Babd B and Popovics J S (1996) Ultrasonic Pulse Velocity Test of Concrete Properties as Specified in Various Standards. Cement and Concrete Composites, Vol. 18, 357-364
  29. Kurtulus C and Bozkurt A (2011) Determination of concrete compressive strength of the structures in Istanbul and Izmit Cities (Turkey) by combination of destructive and non-destructive methods, International Journal of the Physical Sciences Vol. 6(16), 4044-4047
  30. Lin Y, Lai CP and Yen T (2003) Prediction of Ultrasonic Pulse Velocity (UPV) in Concrete. ACI Materials Journal 100 (1), 21–28
  31. Lin, Yiching, Kuo, Shin-Fang, Hsiao, Chiamen and Lai, Chao-Peng (2007) Investigation of pulse velocity-strength relationship of hardened concrete, ACI Materials Journal, Vol.104. No. 4, pp. 344-350
  32. Mac Gregor JG (1983) Load and resistance factors for concrete design, ACI Journal 84(4): 279-287
  33. Malhotra VM and Carino NJ (2004) Handbook on Nondestructive Testing of Concrete. Second edition: ASTM International, CRC Press LLC, USA
  34. Mamlouk MS and Zaniewski JP (2006) Materials for Civil and Construction Engineers, 2nd ed., New Jersey: Pearson Prentice Hall
  35. Metwally abd allah Abd elaty (2014). Compressive strength prediction of Portland cement concrete with age using a new model, HBRC Journal, Volume 10, Issue 2, 145–155
  36. Mirmiran A, Wei Y (2001). Damage assessment of FRP-encased concrete using ultrasonic pulse velocity. J. Eng. Mech., 127: 126-135
  37. Mohammed BS, Azmi NJ and Abdullahi M (2011) Evaluation of rubbercrete based on ultrasonic pulse velocity and rebound hammer tests. Construction and Building Materials, Vol. 25, pp. 1388–1397
  38. Naik TR, Malhotra VM and Popovics JS (2004) The Ultrasonic Pulse Velocity Method,In: V.M. MALHOTRA and N.J. CARINO, Edited 2004, Handbook on Nondestructive Testing of Concrete, Crc Press
  39. Neville AM (1996) Properties of Concrete (4th ed.). New York: J. Wiley
  40. Ohdaira E and Masuzawa N (2000) Water content and its effect on ultrasound propagation in concrete – the possibility of NDE, Ultrasonics, vol.38, 546–552, issues 1–8
  41. Ozer B, Ozkul MH (2004). The influence of initial water curing on the strength development of ordinary Portland and pozzolanic cement concretes. Cem. Concrete Res. 34(1):13-18.
  42. Panzera TH, Christoforo AL, Cota FP, Borges PHR and Bowen CR (2011) Ultrasonic Pulse Velocity Evaluation of Cementitious Materials, Advances in Composite Materials - Analysis of Natural and Man-Made Materials, Dr. Pavla Tesinova (Ed.), ISBN: 978-953-307-449-8, InTech
  43. Pessiki P S and Carino NJ (1988) Setting Time and Strength of Concrete Using the Impact-Echo Method, ACI Materials Journal, V. 85, No. 5, 389-399
  44. Philippidisa TP, Aggeleis DG (2003) An acousto-ultrasonic approach for the determination of water-to-cement ratio in concrete, Cement and Concrete Research 33, 525 – 538
  45. Popovics S, Rose LJ and Popovics J S (1990) The Behavior of Ultrasonic Pulses in Concrete, Cement and Concrete Reaserch, V. 20, No. 2, 259-270
  46. Ramezanianpour AA and VM Malhotra (1995) Effect of Curing on the Compressive Strength, Resistance to Chloride-Ion Penetration and Porosity of Concretes Incorporating Slag, Fly Ash or Silica Fume”, Cement and Concrete Composites, 17(2)
  47. Reinhardt HW and Grosse CU (1996) Setting and hardening of concrete continuously monitored by elastic waves. In Bartos, JPM, Marrs, DL, Cleland, DJ (eds.) Production methods and workability of concrete. Chapman & Hall, London, 415-425
  48. Reinhardt HW, Große CU, Herb AT (2000) Ultrasonic monitoring of setting and hardening of cement mortar – a new device. Materials and Structures, Vol. 33, pp. 580-583
  49. Rollet F, Mansell M, Cochran S (2008) Determining moisture content in concrete under simulated precipitation using ultrasonic propagation time measurements, Nondestructive Testing and evaluation, vol. 23, No. 4, 241–255
  50. Seong-Tae Yi, Jin-Keun Kimb, Tae-Keun Ohc (2003) Effect of strength and age on the stress–strain curves of concrete specimens, Cement and Concrete Research,V. 33, Issue 8, 1235–1244
  51. Shah S, and Patil A (2015) An experimental investigation of effect of variation of curing time on compressive strength of concrete, International Journal of Emerging Technology and Advanced Engineering, Volume 5, Issue 3, 151-154
  52. Subramaniam KV, Mohsen JP, Shaw CK and Shah SP (2002) Ultrasonic technique for monitoring concrete strength gain at early age, ACI Materials Journal, Vol.99. No. 5, 458-462
  53. Tavossi HM, Tittmann BR and Cohen-Tenoudji F (1999) Ultrasonic characterization of cement and concrete, Review of progress in Quantitative Nondestructive Evolution, V./8 Kluwer Academic/ Plenum Publishers, 1943-1948
  54. Trtnik G, Kavcic F, Turk G (2009) Prediction of concrete strength using ultrasonic pulse velocity and artificial neural networks Ultrasonics Vol. 49, 53–60
  55. Uyanık O, Kaptan K, Gülay FG,Tezcan S (2011) Beton dayanımının tahribatsız ultrasonik yöntemle tayini,Yapı Dünyası 184, 55-58
  56. Van der Winden NGB (1990) Ultrasonic measurement for setting control of concrete. In Reinhardt, H.W. (ed.) Testing during concrete construction, Chapman & Hall, London, 122-137
  57. Voigt T, Sun, Zhihui and Shah, Surendra P (2006) Comparison of ultrasonic wave reflection method and maturity method in evaluating early-age compressive strength of mortar, Cement and Concrete Composites, Vol.28. No.4, 307-316
  58. Washa GW and Wendt KF (1975) Fifty-year properties of concrete,ACI Journal proceedins, 72(1). 20-28
  59. Washa GW and Wendt KF (1989) Concrete compressive strength variation with time. Oncrete technology, http://the constructor,org/concrete-compressive-strength-variation-with-time/5933/
  60. Ye G, Brugel KV and Fraaij ALA (2001) Experimental study on ultrasonic pulse velocity evaluation of the microstructure of cementitious material at early age. Heron, V. 46, No.3, ISSN 0046-7316
  61. Yılmaz T and Erçıkdı B (2015) Prediction of the uniaxial compressive strength of paste backfill by ultrasonic pulse velocity test, Türkiye 24. Uluslararası Madencilik Kongresi ve Sergisi, Antalya-Turkey