Dergiler / Journal of the Turkish Chemical Society Section B: Chemical Engineering / 2026 / Volume: 3 Issue: 1

Application of Discrete Time Controllers to A Pilot Scale Packed Distillation Column

Semin Altuntaş(ANKARA ÜNİVERSİTESİ)0000-0003-3183-8650
Hale Hapoğlu(ANKARA ÜNİVERSİTESİ)0000-0003-0464-9483
Sayfa
—
Yayın Tarihi
2020-05-30
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

By comparing all the performances obtained, it can be said that the discrete time controller with two terms tuned by the suggested approach can easily be applied to obtain the most desired performance.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The process involved is a pilot scale packed distillation column that separates a mixture of methanol and water.
📊
Temel Bulgular & Veri:The performances of two discrete time controllers that different parameter tuning techniques were used for each of them were examined in the face of the set point tracking of the overhead product composition.
💡
Sonuç & Katkı:By comparing all the performances obtained, it can be said that the discrete time controller with two terms tuned by the suggested approach can easily be applied to obtain the most desired performance.
🔬Tür:Research Article
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Discrete time controller · packed distillation column · root locus

Abstract

The process involved is a pilot scale packed distillation column that separates a mixture of methanol and water. The performances of two discrete time controllers that different parameter tuning techniques were used for each of them were examined in the face of the set point tracking of the overhead product composition. The success of the discrete time controllers were assessed by means of the rise time and integral of the square error (ISE) criteria. A discrete time proportional integral controller with two terms was obtained by using the velocity form of controller law. For this controller, the proportional sensitivity term (K c ) and the other term were determined by creating root locus diagram and replacing the closed loop poles to the appropriate location in unit circle of z-plane. The most successful proposed controller action was obtained with K c of 0.95 and integral time constant of 2.375 min according to rise time of 3.7 min and ISE criteria of 1.08. The discrete time proportional integral derivative (PID) controller with six parameters as P=0.009185, I=0.01835, D=0, N=100, b=1, c=1 that were tuned by using Simulink control design and 1 min sampling time was applied to the process. The same controller performance with six parameters of P=1.164, I=0.5319, D=-0.01481, N=3.783, b=0.1233, c=0.01017 was investigated by choosing 0.5 min sampling time. By comparing all the performances obtained, it can be said that the discrete time controller with two terms tuned by the suggested approach can easily be applied to obtain the most desired performance.

🔖

Bu Makaleye Atıf Yap

Altuntaş, S., Hapoğlu, H. (2020). Application of Discrete Time Controllers to A Pilot Scale Packed Distillation Column. Journal of the Turkish Chemical Society Section B: Chemical Engineering, Volume: 3 Issue: 1. https://ajindex.com/articles/1426189

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (10)

  1. Aldemir A, Hapoglu H. Comparison of PID tuning methods for wireless temperature control. JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI. 2016;19(1):9–19.
  2. Altuntaş S, Hapoğlu H, Ertunç S, Alpbaz M. Experimental Self-Tuning Proportional Integral Derivative pH Control: Application to a Bioprocess. Acta Phys Pol A. 2017 Sep;132(3–II):1006–9.
  3. Camcıoğlu Ş, Özyurt B, Doğan İC, Hapoğlu H. Application of response surface methodology as a new PID tuning method in an electrocoagulation process control case. Water Science and Technology. 2017 Dec 13;76(12):3410–27.
  4. E. N. Desyatirikova, V. I. Akimov, D. V. Sysoev, V. E. Mager, L. V. Chernenkaya. Selection of Controller Settings in Digital Control Systems. In: 2019 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus). 2019. p. 474–7.
  5. Dincel E, Söylemez MT. Digital PI-PD controller design for arbitrary order systems: Dominant pole placement approach. ISA Transactions. 2018 Aug;79:189–201.
  6. Hinkkanen M, Awan HAA, Qu Z, Tuovinen T, Briz F. Current Control for Synchronous Motor Drives: Direct Discrete-Time Pole-Placement Design. IEEE Transactions on Industry Applications. 2016;52(2):1530–41.
  7. Khan PF, Sengottuvel S, Patel R, Gireesan K, Baskaran R, Mani A. Design and Implementation of a Discrete-Time Proportional Integral (PI) Controller for the Temperature Control of a Heating Pad. SLAS TECHNOLOGY: Translating Life Sciences Innovation. 2018 Dec;23(6):614–23.
  8. Steiner L, Barendreght HP, Hartland S. Concentration profiles in a packed distillation column. Chemical Engineering Science. 1978;33(3):255–62.
  9. Wardle H, Hapoglu H. On the solution of models of binary and multicomponent packed distillation columns using orthogonal collocation on finite elements. Chemical engineering research & design. 1994;
  10. Wardle H, Hapoglu H. On the solution of models of binary and multicomponent packed distillation columns using orthogonal collocation on finite elements. In: Chemical engineering research & design. Zurich, Switzerland: Acta Press; 1993. p. 431–4.