Dergiler / Journal of Thermal Engineering / 2026 / Volume: 8 Issue: 2

Mathematical modeling of semitransparent photovoltaicthermal (SPVT) system with different packing factors: An experimental validation

V.k. Chopra(Galgotias University, Yamuna Expressway, Greater Noida, U.P 201310, India)0000-0003-4057-6170
R.k. Mıshra(Department of Applied Science, Galgotias College of Engineering and Technology, 1, Knowledge Park, Phase II, Greater Noida 201306, India)0000-0002-6933-3618
V. K. Dwıvedı(Madan Mohan Malaviya University of Technology, Deoria Road, Singhariya, Kunraghat, Gorakhpur, 273016, India)0000-0003-2703-6073
B. Mohapatra(Galgotias University, Yamuna Expressway, Greater Noida, U.P 201310, India)0000-0003-1060-2796
Sayfa
—
Yayın Tarihi
2022-03-11
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Case-III gain of 0.7% more as compared to Case-II where as it is 1.7% more gain than case-I.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Solar energy is guided by mix mode photovoltaic cell (PV)having thermal effect not only take a part of electricity generation, besides other fundamental approach is to control the rise in temperature of the cell.
📊
Temel Bulgular & Veri:As the temperature regulated there is very favourable chance of efficiency (electrical) shoots up.In this article, four different experimental set up of mix mode has taken in which a duct made of wood having dimensions 0.86 m × 0.63 m × 0.05 m fixed along with the module in which 10 W capacity DC fan is also incorporated for the circulation of air.
💡
Sonuç & Katkı:Case-III gain of 0.7% more as compared to Case-II where as it is 1.7% more gain than case-I.
🔬Tür:Research Article
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:DC fan · Efficiency (Electrical)

Abstract

Solar energy is guided by mix mode photovoltaic cell (PV)having thermal effect not only take a part of electricity generation, besides other fundamental approach is to control the rise in temperature of the cell. Our main priority of this type of configuration of cell is for electricity generation. Other aspect of controlling temperature of the cell, fluid is used which carries away excessive gain in temperature. In this paper air as fluid is used that pull out undue amount of heat from the cell module. As the temperature regulated there is very favourable chance of efficiency (electrical) shoots up.In this article, four different experimental set up of mix mode has taken in which a duct made of wood having dimensions 0.86 m × 0.63 m × 0.05 m fixed along with the module in which 10 W capacity DC fan is also incorporated for the circulation of air. Various observations deduce from this paper that case-III has the highest efficiency am ong ot her ca ses. On comparing efficiencies with different cases. Case-III gain of 0.7% more as compared to Case-II where as it is 1.7% more gain than case-I.

🔖

Bu Makaleye Atıf Yap

Chopra, V., Mıshra, R., Dwıvedı, V. K., Mohapatra, B. (2022). Mathematical modeling of semitransparent photovoltaicthermal (SPVT) system with different packing factors: An experimental validation. Journal of Thermal Engineering, Volume: 8 Issue: 2. https://doi.org/10.18186/thermal.1086255

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (2)

  1. The article references can be accessed from the.pdf file.
  2. The article references can be accessed from the.pdf file.