Dergiler / Alınteri Zirai Bilimler Dergisi / 2019 / Cilt: 34 - Sayı: 1

Comparison of Spray Transfer and Penetration of Different Hydraulic Nozzles at Low Application Volume

Sayfa
67–75
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The greatest coverage was achieved on front surface of the vertical target and drops reaching to side and rear surfaces were quite low.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Seven hydraulic nozzle types (standard-ST; hollow cone-KH; multirange-LU; standard with narrow angle-STD; antidrift-AD; air-induction-IDK; twinjet air-induction-IDKT) were compared in terms of spray transfer and drop penetration.
📊
Temel Bulgular & Veri:Spray treatments were carried out at a constant application volume of 90 L ha-1 with a linear-motion simulator.
💡
Sonuç & Katkı:The greatest coverage was achieved on front surface of the vertical target and drops reaching to side and rear surfaces were quite low.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Seven hydraulic nozzle types (standard-ST; hollow cone-KH; multirange-LU; standard with narrow angle-STD; antidrift-AD; air-induction-IDK; twinjet air-induction-IDKT) were compared in terms of spray transfer and drop penetration. Spray treatments were carried out at a constant application volume of 90 L ha-1 with a linear-motion simulator. WSP’s were placed onto metal poles and into artificial plant at both horizontal and vertical planes. Two different operating pressures (250 and 500 kPa) and the nozzle position angles (0º and 45º) were used in the experiments. Spray transfer levels at vertical plane were quite lower than the spray transfer levels at horizontal plane. The greatest spray coverage was achieved with LU and ST nozzles producing fine droplets. The greatest drop penetration at vertical plane was obtained from IDK nozzle. Only 25% of the drops transferred to the open target reached the stem and root collar region of the plant canopy. With increasing operating pressures, spray coverage increased by 1,17 times at horizontal plane and 1,50 times at vertical plane. With increasing nozzle position angles, spray coverage at vertical plane increased by 40%. The greatest coverage was achieved on front surface of the vertical target and drops reaching to side and rear surfaces were quite low.

🔖

Bu Makaleye Atıf Yap

SAYINCI, B., DEMİR, B., ÇÖMLEK, R., BOYDAŞ, M. G. (2019). Comparison of Spray Transfer and Penetration of Different Hydraulic Nozzles at Low Application Volume. Alınteri Zirai Bilimler Dergisi, Cilt: 34 - Sayı: 1, 67–75. https://ajindex.com/articles/142373

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (8)

  1. Azimi A. H., Carpenter, T. G. and Reichard, D. L., 1985. Nozzle spray distribution for pesticide application. Transactions of the ASAE 28(5): 1410-1414
  2. Bode, L. E., Butler, B. J., Pearson, S. L. and Bouse, L. F., 1983. Characteristics of the micromax rotary atomizer. Transactions of the ASAE 24(4): 999-1004
  3. Coates, W. and Palumbo, J., 1997. Deposition, off-target movement, and efficacy of CaptureTM and ThiodanTM applied to cantaloupes using five sprayers. Applied Engineering in Agriculture 13(2): 181-188 Foqué, D. and Nuyttens, D., 2011. Effect of air support and spray angle on coarse droplet sprays in ivy pot plants. Transactions of the ASABE 54(2): 409-416
  4. Guler, H., Zhu, H., Ozkan, H. E., Derksen, R. C., Yu, Y., and Krause, C. R., 2006. Spray characteristics and wind tunnel evaluation of drift reduction potential with air induction and conventional flat fan nozzle. In 2006 ASAE Annual Meeting (p. 1). American Society of Agricultural and Biological Engineers Hoffmann, W. C. and Salyani, M., 1996. Spray deposition on citrus canopies under different meteorological conditions. Transactions of the ASAE 39(1): 17-32 Lechler®, 2018. Agricultural Spray Nozzles, 2018 US Catalog. http://www.lechler.de (Available from: April 2018) Malneršič, A., Dular, M., Širok, B., Oberti, R., and Hočevar, M., 2016. Close-range air-assisted precision spot-spraying for robotic applications: Aerodynamics and spray coverage analysis. Biosystems Engineering 146: 216-226 Piché, M., Panneton, B. and Thériault, R., 2000. Reduced drift from air-assisted spraying. Canadian Agricultural Engineering 43(3): 117-122
  5. Reed, J. T. and Smith, D. B., 2001. Droplet size and spray volume effects on insecticide deposit and mortality of Heliothine (Lepidoptera: Noctuidae) larvae in cotton. Journal of Economic Entomology 94(3): 640-647
  6. Salyani, M. and Whitney, J. D., 1988. Evaluation of methodologies for field studies of spray deposition. Transactions of the ASAE 31(2): 390-395
  7. Salyani, M., Zhu, H., Sweeb, R. D. and Pai, N., 2013. Assessment of spray distribution with water-sensitive paper. Agric Eng Int: CIGR Journal 15(2): 101-111
  8. Sanchez-Hermosilla, J. and Medina, R., 2004. Adaptive threshold for droplet spot analysis using water-sensitive paper. Applied Engineering in Agriculture 20(5): 547- 551 Sayıncı, B. and Bastaban, S., 2009. İlaç uygulama performansının değerlendirilmesinde kalitatif ve kantitatif analiz yöntemlerinin değerlendirilmesi, Anadolu Tarım Bilimleri Dergisi 24(2): 133-140 (in Turk