Dergiler / Gazi Mühendislik Bilimleri Dergisi / 2026 / Volume: 11 Issue: 2

Hip Prosthesis Design with a Shock Absorber

Sayfa
—
Yayın Tarihi
2025-08-31
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

This finding suggests that the prosthesis could help reduce the frequency of revision arthroplasty surgeries..

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The conventional hip prostheses and the implanted bone are subjected to high stresses and strains under sudden and shock loadings (jumping, sudden movements, falling, etc.).
📊
Temel Bulgular & Veri:In order to reduce these stresses and strains, we were inspired by a simple mechanical damper to design a hip prosthesis by incorporating a shock absorber proximally.
💡
Sonuç & Katkı:This finding suggests that the prosthesis could help reduce the frequency of revision arthroplasty surgeries..
🔬Tür:Research Article
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Hip prosthesis · Shock absorber · Finite element analysis

Abstract

The conventional hip prostheses and the implanted bone are subjected to high stresses and strains under sudden and shock loadings (jumping, sudden movements, falling, etc.). In order to reduce these stresses and strains, we were inspired by a simple mechanical damper to design a hip prosthesis by incorporating a shock absorber proximally. Initially, hip prostheses with similar stem dimensions, Type A (conventional), Type B (spring based), and Type C (shock absorber based), were designed by considering prosthesis design parameters. Then, finite element analysis was performed for all three prostheses. Boundary conditions, such as physiological forces and fixations, were applied as suggested in studies reported in the literature. Once the simulations were completed, the time-dependent stress and deformation responses of the shock absorber-based and spring-based prostheses under sudden loading conditions were compared with those of the conventional prosthesis. The results showed that the stresses and strains in the shock absorber-based prosthesis were lower than those in both the spring-based and conventional prostheses. This finding suggests that the prosthesis could help reduce the frequency of revision arthroplasty surgeries..

🔖

Bu Makaleye Atıf Yap

Narin, M., Pekedis, M. (2025). Hip Prosthesis Design with a Shock Absorber. Gazi Mühendislik Bilimleri Dergisi, Volume: 11 Issue: 2. https://ajindex.com/articles/1397363

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (19)

  1. M. Narin, "Design of a Hip Prosthesis with a Shock Absorber," M.Sc. thesis, Ege University, Graduate School of Natural and Applied Sciences, İzmir, 2024.
  2. M. Pekedis, A.A. Karaarslan, F. Ozan, M. Tahta, and C. Kayali, “Novel anchor-type proximal femoral nail for the improvement of bone-fixation integrity in treating intertrochanteric fractures: an experimental and computational characterization study,” Computer Methods in Biomechanics and Biomedical Engineering, pp. 1-17, Jan. 2025. doi:10.1080/10255842.2025.2456985
  3. M. Pekedis, F. Ozan, and M. Melez, “Location-dependent biomechanical characterization of the human Achilles tendon in diabetic and nondiabetic patients,” ASME Journal of Biomechanical Engineering, vol. 147, no. 5, pp. 1-18, May 2025. doi:10.1115/1.4068015
  4. F. Ozan, K. T. Okur, F. Mavi, and M. Pekedis, “Biomechanical and clinical assessment of dissociation in bipolar hip hemiarthroplasty,” Bio-Medical Materials and Engineering, vol. 36, no. 3, pp. 185-199, Jan. 2025. doi:10.1177/09592989241306688
  5. A. Fontalis, J. A. Epinette, M. Thaler, L. Zagra, V. Khanduja, and F. S. Haddad, “Advances and innovations in total hip arthroplasty,” SICOT-J, vol. 7, no. 26, pp. 1-10, Apr. 2021. doi:10.1051/sicotj/2021025
  6. A. D. Martino, “Observations on the Present and the Future of Hip Surgery,” Journal of Clinical Medicine, vol. 12, no. 10, May 2023. doi:10.3390/jcm12103464
  7. K. D. Moore, P.R. Beck, D.W. Petersen, J. M. Cuckler, J. E. Lemons, and A. W. Eberhardt, “Early failure of a cross-linked polyethylene acetabular liner,” The Journal of Bone and Joint Surgery, vol. 90, no. 11, pp. 2499–2504, Nov. 2008. doi:10.2106/JBJS.G.01304
  8. K. J. Bozic and H. E. Rubash, “The Painful Total Hip Replacement,” Clinical Orthopaedics and Related Research, vol. 420, pp. 18–25, Mar. 2004. doi:10.1097/00003086-200403000-00004
  9. O. Kayabasi and F. Erzincanli, “Finite element modelling and analysis of a new cemented hip prosthesis,” Advances in Engineering Software, vol. 37, no. 7, pp. 477-483, July 2006. doi:10.1016/j.advengsoft.2005.09.003
  10. K. Colic, A. Sedmak, A. Grbovic, U. Tatic, S. Sedmak, and B. Djordjevic, “Finite Element Modeling of Hip Implant Static Loading,” Procedia Engineering, vol. 149, pp. 257–262, 2016. doi:10.1016/j.proeng.2016.06.664
  11. A. Heijink, M. Zobitz, R. Nuyts, B. Morrey, and K. An, “Prosthesis Design and Stress Profile after Hip Resurfacing: A Finite Element Analysis,” Journal of Orthopaedic Surgery, vol. 16, no. 3, pp. 326–332, Dec. 2008. doi:10.1177/230949900801600312
  12. İ. Mutlu and A. Dizdar, “Mechanical evaluation of an epiphysis prosthesis as an alternative to conventional total hip prosthesis,” Journal of Polytechnic, vol. 26, no. 1, pp. 73–79, 2023. doi:10.2339/politeknik.950183
  13. K. Chua, A. K. S. Yew, and N. N. Lo, Hip prosthesis devices, WO Patent 048244, issued 2016.
  14. S. R. Goli and A. Goli, Modular hip implant with shock absorption system, U.S. Patent 0051831A1, issued 2001.
  15. M. Papini, R. Zdero, E. H. Schemitsch, and P. Zalzal, “The biomechanics of human femurs in axial and torsional loading: Comparison of finite element analysis, human cadaveric femurs, and synthetic femurs,” Journal of Biomechanical Engineering, vol. 129, no. 1, pp. 12–19, 2007. doi:10.1115/1.2401178
  16. G. Bergmann, A. Bender, J. Dymke, G. Duda, and P. Damm, “Standardized Loads Acting in Hip Implants,” PloS One, vol. 11, no. 5, e0155612, May 2016. doi:10.1371/journal.pone.0155612
  17. International Organization for Standardization, ISO 7206-4: Partial and total hip joint prostheses—Part 4: Determination of endurance properties and performance of stemmed femoral components, ISO Standard 7206-4, 2010.
  18. A. Ruggiero, R. D’Amato, and S. Affatato, “Comparison of Meshing Strategies in THR Finite Element Modelling,” Materials, vol. 12, no. 14, pp. 2332, Jul. 2019. doi:10.3390/ma12142332
  19. J. L. Montes-Seguedo, A. L. Garcia-Garcia, J. D. O. Barceinas-Sanchez, et al., "Mapping the friction coefficient of AISI 316L on UHMWPE lubricated with bovine serum to study the effect of loading and entrainment at high values of sliding-to-rolling ratio," Health Technol., vol. 10, pp. 385–390, 2020, doi:10.1007/s12553-019-00355-y