Dergiler / Turkish Journal of Veterinary and Animal Sciences / 2013 / Cilt: 37 - Sayı: 1

Whole-blood thrombelastography using calcium chloride activation in healthy cats

Sayfa
68–75
Yayın Tarihi
2013-01-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

It should be useful for detecting hypo- and hypercoagulable states in cats with hemostatic disturbances.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Thrombelastography (TEG, Haemoscope Corp., Niles, IL, USA) allows for a global evaluation of the hemostatic system; while conventional coagulation tests typically evaluate only one part of the coagulation system, TEG simultaneously examines the interaction between platelets, clotting factors, the fibrinolytic system, and clot retraction mechanisms.
📊
Temel Bulgular & Veri:The purpose of this study was to establish TEG reference ranges in healthy cats using the citrated native technique.
💡
Sonuç & Katkı:It should be useful for detecting hypo- and hypercoagulable states in cats with hemostatic disturbances.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Key words: Thrombelastography · hemostasis · viscoelasticity

Özet

Thrombelastography (TEG, Haemoscope Corp., Niles, IL, USA) allows for a global evaluation of the hemostatic system; while conventional coagulation tests typically evaluate only one part of the coagulation system, TEG simultaneously examines the interaction between platelets, clotting factors, the fibrinolytic system, and clot retraction mechanisms. Since its development, TEG has been widely employed in human clinical medicine and research, but has only recently gained popularity in veterinary medicine. The purpose of this study was to establish TEG reference ranges in healthy cats using the citrated native technique. In this study, 31 clinically healthy cats were evaluated. We sampled healthy adult cats based on the absence of clinical signs of illness, normal physical examination findings, a complete blood count, hemostasis profile results, and no previous history of bleeding disorders. The cats had 2 distinct tracings: a 'normal' tracing similar to that obtained in other species, and a 'high lysis' tracing. The percent of lysis at 60 min (LY60) was significantly higher and the percent of lysis at 60 min after MA is reached (CL60) was significantly lower in the 'high lysis' group (P < 0.001 for both). Cats in the 'high lysis' group also had a significantly shorter reaction time (P = 0.02). Based on the results, citrated native TEG may provide valuable information on global hemostasis in cats. This technique has a high coefficient of variation for the reaction time, kinetic time, and LY60 parameters, likely due to platelet retraction. It should be useful for detecting hypo- and hypercoagulable states in cats with hemostatic disturbances.

Abstract

Thrombelastography (TEG, Haemoscope Corp., Niles, IL, USA) allows for a global evaluation of the hemostatic system; while conventional coagulation tests typically evaluate only one part of the coagulation system, TEG simultaneously examines the interaction between platelets, clotting factors, the fibrinolytic system, and clot retraction mechanisms. Since its development, TEG has been widely employed in human clinical medicine and research, but has only recently gained popularity in veterinary medicine. The purpose of this study was to establish TEG reference ranges in healthy cats using the citrated native technique. In this study, 31 clinically healthy cats were evaluated. We sampled healthy adult cats based on the absence of clinical signs of illness, normal physical examination findings, a complete blood count, hemostasis profile results, and no previous history of bleeding disorders. The cats had 2 distinct tracings: a 'normal' tracing similar to that obtained in other species, and a 'high lysis' tracing. The percent of lysis at 60 min (LY60) was significantly higher and the percent of lysis at 60 min after MA is reached (CL60) was significantly lower in the 'high lysis' group (P < 0.001 for both). Cats in the 'high lysis' group also had a significantly shorter reaction time (P = 0.02). Based on the results, citrated native TEG may provide valuable information on global hemostasis in cats. This technique has a high coefficient of variation for the reaction time, kinetic time, and LY60 parameters, likely due to platelet retraction. It should be useful for detecting hypo- and hypercoagulable states in cats with hemostatic disturbances.

🔖

Bu Makaleye Atıf Yap

ÇÖL, R., MONTGOMERY, A., IAZBIK, M. C., DEFELICE, A., SAAVEDRA, P. V., COUTO, G. (2013). Whole-blood thrombelastography using calcium chloride activation in healthy cats. Turkish Journal of Veterinary and Animal Sciences, Cilt: 37 - Sayı: 1, 68–75. https://ajindex.com/articles/122148

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Lisciandro, S.C., Hohenhaus, A., Brooks, M.: Coagulation abnormalities in 22 cats with naturally occurring liver disease. J. Vet. Intern. Med., 1998; 12: 71–75.
  2. Peterson, J.L., Couto, C.G., Wellman, M.L.: Hemostatic disorders in cats: a retrospective study and review of the literature. J. Vet. Intern. Med., 1995; 9: 298–303.
  3. Kristensen, A.T., Wiinberg, B., Jessen, L.R., Andreasen, E., Jensen, A.L.: Evaluation of human recombinant tissue factoractivated thromboelastography in 49 dogs with neoplasia. J. Vet. Intern. Med., 2008; 22: 140–147.
  4. Wiinberg, B., Jensen, A.L., Rozanski, E., Johansson, E.P., Kjelgaard-Hansen, M., Tranholm, M., Kristensen, A.T.: Tissue factor activated thromboelastography correlates to clinical signs of bleeding in dogs. Vet. J., 2009; 179: 121–129.
  5. Dempfle, C.E.: Perioperative coagulation diagnostics. Der Anaesthesist, 2005; 54: 167–175.
  6. Donahue, S.M., Otto, C.M.: Thromboelastography: a tool for measuring hypercoagulability, hypocoagulability, and fibrinolysis. J. Vet. Emerg. Crit. Care, 2005; 15: 9–16.
  7. Shore-Lesserson, L., Manspeizer, H.E., DePerio, M.: Thromboelastography-guided transfusion algorithm reduces transfusions in complex cardiac surgery. Anesth. Analg., 1999; 88: 312–319.
  8. Gillies, B.S.: Thromboelastography and liver transplantation. Semin. Thromb. Hemost., 1995; 21(4): 45–49.
  9. Othman, M., Powell, S., Chirinian, Y., Hegadorn, C., Hopman, W., Lillicrap, D.: Thromboelastography reflects global hemostatic variation among severe haemophilia A dogs at rest and following acute exercise. Haemophilia, 2009; 15: 1126–34.
  10. Alwood, A.J., Downend, A.B., Brooks, M.B., Slensky, K.A., Fox, J.A., Simpson, S.A., Waddell, L.S., Baumgardner, J.E., Otto, C.M.: Anticoagulant effects of low-molecular-weight heparins in healthy cats. J. Vet. Intern. Med., 2007; 21: 378–387.
  11. Marschner, C.B., Bjİrnvad, C.R., Kristensen, A.T., Wiinberg, B.: Thromboelastography results on citrated whole blood from clinically healthy cats depend on modes of activation. Acta Vet. Scand., 2010; 52: 38. Öberg, J., Tvedten, H.: Thromboelastography in a cat with steroid responsive thrombocytopenia. Comp. Clin. Pathol., 2010; 19: 429–431.
  12. Haggstrom, J.: Hypertrophic cardiomyopathy in cats—it used to be so simple. J. Feline Med. Surg., 2003; 5: 139–141.
  13. Ciaramella, P., Piantedosi, D., Lindquist, E., Di Loria, A., Cortese, L., Skeels, M., Persechino, A.: Plasma thrombomodulin (TM) concentration in cats with cardiomyopathies. Vet. Res. Commun., 2006; 30: 289–291.
  14. Fox, P.R. Feli