Of these, only 0.78% of the liver samples were found to exceed the Codex maximum residue limit (MRL) for chlorpyrifos.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Food safety is of great importance to all involved in the food chain.
📊
Temel Bulgular & Veri:In the present study, 254 buffalo liver tissue samples were collected from 4 slaughterhouses and analyzed both qualitatively and quantitatively for the presence of chlorpyrifos residues.
💡
Sonuç & Katkı:Of these, only 0.78% of the liver samples were found to exceed the Codex maximum residue limit (MRL) for chlorpyrifos.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Key words: Residue · chlorpyrifos · buffalo liver tissue

Özet

Food safety is of great importance to all involved in the food chain. The problem of pesticide residues is one of the concerns for the consumers. In the present study, 254 buffalo liver tissue samples were collected from 4 slaughterhouses and analyzed both qualitatively and quantitatively for the presence of chlorpyrifos residues. The samples were processed by extraction with acetonitrile followed by sonication and liquid-liquid partition. The extracts were cleaned up by performing alumina column chromatography. Chlorpyrifos residues in the samples were detected and quantified by employing high performance liquid chromatography. High performance liquid chromatography (HPLC) was performed by using the isocratic mobile phase, consisting of acetonitrile and water at a ratio of 67:33 with a flow rate of 1 mL/min and a run time of 18 min. The detection wavelength was set at 202 nm with 360 nm as the reference wavelength. Chlorpyrifos residues were detected in 9.05% of the samples. Of these, only 0.78% of the liver samples were found to exceed the Codex maximum residue limit (MRL) for chlorpyrifos.

Abstract

Food safety is of great importance to all involved in the food chain. The problem of pesticide residues is one of the concerns for the consumers. In the present study, 254 buffalo liver tissue samples were collected from 4 slaughterhouses and analyzed both qualitatively and quantitatively for the presence of chlorpyrifos residues. The samples were processed by extraction with acetonitrile followed by sonication and liquid-liquid partition. The extracts were cleaned up by performing alumina column chromatography. Chlorpyrifos residues in the samples were detected and quantified by employing high performance liquid chromatography. High performance liquid chromatography (HPLC) was performed by using the isocratic mobile phase, consisting of acetonitrile and water at a ratio of 67:33 with a flow rate of 1 mL/min and a run time of 18 min. The detection wavelength was set at 202 nm with 360 nm as the reference wavelength. Chlorpyrifos residues were detected in 9.05% of the samples. Of these, only 0.78% of the liver samples were found to exceed the Codex maximum residue limit (MRL) for chlorpyrifos.

🔖

Bu Makaleye Atıf Yap

KUMAR, P., SINGH, S., SHRIKANT, K., MADHUKAR, D. (2011). Analysis of buffalo liver samples for the presence of chlorpyrifos residues by using high performance liquid chromatography. Turkish Journal of Veterinary and Animal Sciences, Cilt: 35 - Sayı: 4, 219–226. https://ajindex.com/articles/122035

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (9)

  1. MOHFW: Pesticides and Good Agricultural Practices. Ministry of Health and Family Welfare, India. 2004. http:// mohfw.nic.in/pfa.htm. 2. Meena, M.: Forget colas, what about the pesticides in your wheat, water and breastmilk? Infochange Toxic Tours-XII, 2003. 3. Garg, S.K.: Veterinary toxicology. In: Reproductive Toxicity, Teratogenicity and Embryotoxicity. CBS Publishers and Distributors, Darya Ganj, New Delhi. 2000; 281-290.
  2. Rawlings, N.C., Cook, S.J., Waldbillig, D.: Eff ects of the pesticides carbofuran, chlorpyrifos, dimethoate, lindane, triallate, trifl uralin, 2,4-D, and pentachlorophenol on the metabolic endocrine and reproductive endocrine system in ewes. J. Toxico. and Environ. Health Part A, 1998; 54: 21-36. 5. FAO Production Year Book. 2004. http://www.fao.org. 6. Ranjhan, S.K.: Problems and prospects in safe and quality meat production. Proceedings of National Seminar on Food Quality and Safety Standards of Agricultural Raw and Processed Produce, New Delhi, India. 2005; 54-57.
  3. Carrera, G., Periquet, A.: Metabolism and toxicokinetics of pesticides in animals. In: Dikshit, T.S.S., Ed. Toxicology of Pesticides in Animals. CRC Press,
  4. Boca Raton, FL. 1991; 67- 118. 8. Casida, J.M.: Metabolism of organophosphorous insecticides in relation to their antiesterase activity, stability and residual properties. J. Agri. Food Chem., 1956; 4: 772. Chambers, H.W.: Organophosphorous compounds: An overview. In: Chambers, J.E. and Levi, P.E., Eds. Organophosphates: Chemistry, Fate and Eff ects. Academic Press, New York. 1992; 3-17.
  5. Gilman, A.G., Hardman, J.G., Limbird, L.E., Molinoff, P.B., Ruddon, R.W.: Th e Pharmacological Basis of Th erapeutics, international edition, 9th ed., McGraw-Hill. 1996; 169. Roy, B.K.: Veterinary pharmacology and toxicology. In: Toxicity Caused by Food Additives and Preservatives. Kalyani Publishers. 2001; 537-545.
  6. James, F.L., Davida, T.: High performance liquid chromatography data for 166 pesticides. J. Chromato., 1978; 159: 207-226.
  7. Bottomley, P., Baker, P.G.: Multi-residue determination of organochlorine, organophosphorous and synthetic pyrethroid pesticides in grain by gas-liquid and high performance liquid chromatography. Analyst, 1984; 109: 85-90.
  8. Watanabe, K., Suzuki, K., Saito, T., Itoh, T.: Investigation of an analytical method for pesticides in beef by high performance liquid chromatography. Ani. Sci. Techno., 1991; 62: 909-914.
  9. Cho, Y., Matsuoka, N., Kamiya, A.: Determination of organophosphorous pesticides in biological s