Energy Yield Estimation, Installation and Monitoring of 3-Phase Grid Connected PV System

Sayfa
393–398
Yayın Tarihi
2016-12-26
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The PV system has produced 50.522 kWh energy from January to April, 2014.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:This paper describes installation and analysis of photovoltaic system (PV) which has been installed in Soke/Aydin, Turkey.
📊
Temel Bulgular & Veri:In order to minimize losses, for the first time in Turkey the PV panels were placed both on North and South facade with 15 and 10 degree angle to the South, contrary to traditional roof installed PV systems.
💡
Sonuç & Katkı:The PV system has produced 50.522 kWh energy from January to April, 2014.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:2014 Verileri
⚙️Değişkenler:Annual Energy Yield · Grid Connected PV · Installation

Abstract

This paper describes installation and analysis of photovoltaic system (PV) which has been installed in Soke/Aydin, Turkey. Generally, the PV systems are installed on roof according to inclination of roof as well north facade. Therefore, large losses occur. In order to minimize losses, for the first time in Turkey the PV panels were placed both on North and South facade with 15 and 10 degree angle to the South, contrary to traditional roof installed PV systems. In this way it was determined that efficiency of PV panels especially the ones that are positioned at North facade were increased by 10%. The simulation of the system was done using different sun irradiation sources such as Geomodel, Meteocontrol, Meteonom and PVGIS. The total DC power of the system is 155.3 kWp. Annual electricity production amount and performance ratio was calculated as 243 MWh and 80.9% respectively for the first year. The uncertainty of the models and calculation steps with respect to the average specific yield and average yield is estimated to be ± 7.1% assuming a simple standard deviation. The PV system has produced 50.522 kWh energy from January to April, 2014.

🔖

Bu Makaleye Atıf Yap

BAŞARAN, K. (2016). Energy Yield Estimation, Installation and Monitoring of 3-Phase Grid Connected PV System. Celal Bayar Üniversitesi Fen Bilimleri Dergisi, Cilt: 12 - Sayı: 3, 393–398. https://ajindex.com/articles/115385