Dergiler / Turkish Journal of Medical Sciences / 2015 / Cilt: 45 - Sayı: 2

Bioimpedance for assessing volume status in children with nephrotic syndrome

Sayfa
339–344
Yayın Tarihi
2015-08-13
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion: Our data suggest that bioimpedance may be superior to echocardiography in determining volume load in children with NS, because it is cost-effective, reliable, and relatively simple to perform.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Background/aim: The effectiveness of assessing volume load via bioimpedance in pediatric patients with nephrotic syndrome (NS) was investigated.
📊
Temel Bulgular & Veri:Materials and methods: Patients with NS (n = 34) were compared with healthy controls (n = 20).
💡
Sonuç & Katkı:Conclusion: Our data suggest that bioimpedance may be superior to echocardiography in determining volume load in children with NS, because it is cost-effective, reliable, and relatively simple to perform.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Nephrotic syndrome · children · volume status

Özet

Background/aim: The effectiveness of assessing volume load via bioimpedance in pediatric patients with nephrotic syndrome (NS) was investigated. Materials and methods: Patients with NS (n = 34) were compared with healthy controls (n = 20). The inferior vena cava index and inferior vena cava collapsibility index (IVCCI) scores were determined for all subjects. Bioimpedance measurements were used to directly determine volume load. Clinical findings, relative fluid load, and echocardiographic measurements were determined and compared with bioimpedance in calculating volume load. Results: The sensitivity and specificity of bioimpedance in determining volume load were found to be 65% and 90%, respectively. IVCCI was lower in NS patients than in controls. There were also significant differences in IVCCI values between patients with localized and generalized edema. Relative fluid load was higher in NS patients with generalized edema as opposed to patients with localized edema. For calculating volume load, the sensitivity of bioimpedance, clinical findings, and echocardiographic measurements was 87%, 95%, and 83%, respectively, whereas the specificity of determining volume load by bioimpedance, clinical findings, and echocardiographic measurements was 50%, 10%, and 80%, respectively. Conclusion: Our data suggest that bioimpedance may be superior to echocardiography in determining volume load in children with NS, because it is cost-effective, reliable, and relatively simple to perform.

Abstract

Background/aim: The effectiveness of assessing volume load via bioimpedance in pediatric patients with nephrotic syndrome (NS) was investigated. Materials and methods: Patients with NS (n = 34) were compared with healthy controls (n = 20). The inferior vena cava index and inferior vena cava collapsibility index (IVCCI) scores were determined for all subjects. Bioimpedance measurements were used to directly determine volume load. Clinical findings, relative fluid load, and echocardiographic measurements were determined and compared with bioimpedance in calculating volume load. Results: The sensitivity and specificity of bioimpedance in determining volume load were found to be 65% and 90%, respectively. IVCCI was lower in NS patients than in controls. There were also significant differences in IVCCI values between patients with localized and generalized edema. Relative fluid load was higher in NS patients with generalized edema as opposed to patients with localized edema. For calculating volume load, the sensitivity of bioimpedance, clinical findings, and echocardiographic measurements was 87%, 95%, and 83%, respectively, whereas the specificity of determining volume load by bioimpedance, clinical findings, and echocardiographic measurements was 50%, 10%, and 80%, respectively. Conclusion: Our data suggest that bioimpedance may be superior to echocardiography in determining volume load in children with NS, because it is cost-effective, reliable, and relatively simple to perform.

🔖

Bu Makaleye Atıf Yap

ÖZDEMİR, K., MİR, M. S., DİNÇEL, N., BOZABALI, S., BULUT, İ. K., YILMAZ, E., SÖZERİ, B. (2015). Bioimpedance for assessing volume status in children with nephrotic syndrome. Turkish Journal of Medical Sciences, Cilt: 45 - Sayı: 2, 339–344. https://ajindex.com/articles/114010

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (11)

  1. Glassock RJ, Cohen AH, Adler SG. Primary glomerular disease. In: Brenner BM, editor. The Kidney. 5th ed. Philadelphia, PA, USA: WB Saunders; 1996. pp. 1392–1497.
  2. Vande Walle JG, Donckerwolcke RA, Van Isselt JW, Derkx FHM, Joles JA, Koomans HA. Volume regulation in children with early relapse of minimal change nephrosis with or without hypovolemic symptoms. Lancet 1995; 346: 148–152.
  3. Geers AB, Koomans HA, Boer EJ, Mees Dorhout EJ. Plasma and blood volumes in patients with nephrotic syndrome. Nephron 1984; 38: 170–173.
  4. Koomans HA, Geers AB, Mees Dorhout EJ, Kortlandt W. Lowered tissue fluid oncotic pressure protects the blood volume in the nephrotic syndrome. Nephron 1986; 42: 317– 322. Schnaper HW, Robson AM. Nephrotic syndrome. In: Schrier RW, editor. Disease of the Kidney and Urinary Tract. 7th ed. Philadelphia, PA, USA: Lippincott Williams & Wilkins; 2001. pp. 1773–1832.
  5. Vande Walle J, Donckerwolcke R, Boer P, Van Isselt HW, Koomans HA, Joles JA. Blood volume, colloid osmotic pressure and F-cell ratio in children with the nephrotic syndrome. Kidney Int 1996; 49: 1471–1477. 7. Andreoli TE. Edematous states: an overview. Kidney Int 1997; 51: 21–27.
  6. Ruffmann K, Mandelbaum A, Bommer J, Schmidli M, Ritz E. Doppler echocardiographic findings in dialysis patients. Nephrol Dial Transplant 1990; 5: 426–431. Weyman A. Right ventricular inflow tract. In: Weyman A, editor. Principles and Practice of Echocardiography. 2nd ed. Philadelphia, PA, USA: Lea and Febiger; 1994. pp. 853–854.
  7. Krause I, Birk E, Davidovits M, Cleper R, Blieden L, Pinhas L. Inferior vena cava diameter: a useful method for estimation of fluid status in children on haemodialysis. Nephrol Dial Transplant 2001; 16: 1203–1206.
  8. Cheriex EC, Leunissen KM, Janssen JH, Mooy JM, van Hooff JP. Echography of the inferior vena cava is a simple and reliable tool for estimation of “dry weight” in haemodialysis patients. Nephrol Dial Transplant 1989; 4: 563–568.
  9. Mandelbaum A, Ritz E. Vena cava diameter measurement for estimation of dry weight in haemodialysis patients. Nephrol Dial Transplant 1996; 11: 24–27.
  10. Buchholdz AC, Bartok C, Schoeller DA. The validity of bioelectrical impedance models in clinical populations. Nutr Clin Pract 2004; 19: 433–446.
  11. Lee SW, Song JH, Kim GA, Lee KJ, Kim MJ. Assessment of total body water from anthropometry-based equations using bioelectrical impedance as reference in Korean adult control and haemodialysis subjects. Nephrol Dial Transplant 2001; 16: 91–97. Park MK. Chest roentg