Dergiler / Turkish Journal of Medical Sciences / 2016 / Cilt: 46 - Sayı: 3

Clinical outcomes and optical performance of four differentmultifocal intraocular lenses

Sayfa
597–603
Yayın Tarihi
2016-06-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion: All four multifocal lens designs provided satisfactory visual functions and CS results in patients who fulfilled the criteria for multifocal lens implantation.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Background/aim: The purpose of the present study was to evaluate clinical outcomes and optical performance of 4 different multifocal intraocular lenses (IOLs).
📊
Temel Bulgular & Veri:Materials and methods: Ninety eyes of 51 patients who received Reviol MFM 611, Reviol MFM 625, Acri.LISA, and ReSTOR SN6AD3 multifocal IOLs after cataract surgery were retrospectively evaluated.
💡
Sonuç & Katkı:Conclusion: All four multifocal lens designs provided satisfactory visual functions and CS results in patients who fulfilled the criteria for multifocal lens implantation.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Cataract surgery · multifocal IOLs · phacoemulsification

Abstract

Background/aim: The purpose of the present study was to evaluate clinical outcomes and optical performance of 4 different multifocal intraocular lenses (IOLs). Materials and methods: Ninety eyes of 51 patients who received Reviol MFM 611, Reviol MFM 625, Acri.LISA, and ReSTOR SN6AD3 multifocal IOLs after cataract surgery were retrospectively evaluated. The patients were similar in terms of age, sex, cataract hardness and axial length. The mean outcome measures were uncorrected and corrected distance visual acuity (UDVA, CDVA), distance-corrected intermediate and near visual acuity (DCIVA, DCNVA), intra or postoperative complications, and contrast sensitivity (CS) results under mesopic conditions. The mean follow up period was 10.5 months (range: 6-12 months). Results: All cases were within ± 0.75 D of emmetropia. Postoperative increase in UDVA and DCNVA was statistically significant in all groups. The Acri.LISA group showed slightly lower DCIVA compared with the other IOLs. CS was clinically similar between the groups. None of the patients developed any early or late postoperative complication or neuroadaptation problem, which necessitated explantation of the lens. Conclusion: All four multifocal lens designs provided satisfactory visual functions and CS results in patients who fulfilled the criteria for multifocal lens implantation.

🔖

Bu Makaleye Atıf Yap

CERAN, B. B., TAKMAZ, T., CAN, İ., DEMİROK, G., UYSAL, B. S. (2016). Clinical outcomes and optical performance of four differentmultifocal intraocular lenses. Turkish Journal of Medical Sciences, Cilt: 46 - Sayı: 3, 597–603. https://ajindex.com/articles/113882

📄 Tam Metin PDF Okuyucu

📄