Dergiler / Turkish Journal of Medical Sciences / 2018 / Cilt: 48 - Sayı: 1

Diagnostic utility of the sonographic median to ulnar nerve cross-sectional area ratio in carpal tunnel syndrome

Sayfa
110–116
Yayın Tarihi
2018-02-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion: The ratio of m-CSA/u-CSA at the level of the pisiform bone was not detected to be superior to m-CSA in the diagnosis of CTS.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Background/aim: The aim of this study was to assess the diagnostic utility of the ultrasonographic ratio of median nerve cross-sectional area (m-CSA) to ulnar nerve cross-sectional area (u-CSA), the m-CSA/u-CSA ratio, in carpal tunnel syndrome (CTS).
📊
Temel Bulgular & Veri:Materials and methods: Fifty patients with positive symptoms and electromyography results of CTS and 50 healthy matched control subjects were evaluated.
💡
Sonuç & Katkı:Conclusion: The ratio of m-CSA/u-CSA at the level of the pisiform bone was not detected to be superior to m-CSA in the diagnosis of CTS.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Ultrasonography · ulnar nerve · ratio

Abstract

Background/aim: The aim of this study was to assess the diagnostic utility of the ultrasonographic ratio of median nerve cross-sectional area (m-CSA) to ulnar nerve cross-sectional area (u-CSA), the m-CSA/u-CSA ratio, in carpal tunnel syndrome (CTS). Materials and methods: Fifty patients with positive symptoms and electromyography results of CTS and 50 healthy matched control subjects were evaluated. Ultrasonographic m-CSA and u-CSA measurements of each participant were made at the level of the pisiform bone and the m-CSA/u-CSA ratio was calculated. Results: Using the m-CSA cut-off value of 11.95 mm2 showed a sensitivity of 80% and a specificity of 80% while using a cut-off value 2.95 for the ratio of m-CSA/u-CSA showed a sensitivity of 86% and a specificity of 72% in the diagnosis of CTS. Conclusion: The ratio of m-CSA/u-CSA at the level of the pisiform bone was not detected to be superior to m-CSA in the diagnosis of CTS.

🔖

Bu Makaleye Atıf Yap

ATAN, T., GÜNENDİ, Z. (2018). Diagnostic utility of the sonographic median to ulnar nerve cross-sectional area ratio in carpal tunnel syndrome. Turkish Journal of Medical Sciences, Cilt: 48 - Sayı: 1, 110–116. https://ajindex.com/articles/113575

📄 Tam Metin PDF Okuyucu

📄