Dergiler / Turkish Journal of Medical Sciences / 2018 / Cilt: 48 - Sayı: 5

Effects of tourniquet usage in lower extremity surgery on optic nerve sheath diameter

Sayfa
980–984
Yayın Tarihi
2018-10-31
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion: The ultrasonographic ONSD measurements, which were obtained using a simple and noninvasive approach, increased significantly following tourniquet deflation, and this increase was correlated with an increase in ETCO2.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Background/aim: The aim of this study was to evaluate changes in intracranial pressure following tourniquet deflation using noninvasive ultrasonographic optic nerve sheath diameter (ONSD) measurements.
📊
Temel Bulgular & Veri:Materials and methods: Our study included 59 adult patients between the ages of 18 and 65 years from the American Society of Anesthesiologists (ASA) I/II risk groups who were scheduled to undergo elective orthopedic surgery of the lower extremities using a tourniquet under general anesthesia.
💡
Sonuç & Katkı:Conclusion: The ultrasonographic ONSD measurements, which were obtained using a simple and noninvasive approach, increased significantly following tourniquet deflation, and this increase was correlated with an increase in ETCO2.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Tourniquet · intracranial pressure · optic nerve sheath diameter

Abstract

Background/aim: The aim of this study was to evaluate changes in intracranial pressure following tourniquet deflation using noninvasive ultrasonographic optic nerve sheath diameter (ONSD) measurements. Materials and methods: Our study included 59 adult patients between the ages of 18 and 65 years from the American Society of Anesthesiologists (ASA) I/II risk groups who were scheduled to undergo elective orthopedic surgery of the lower extremities using a tourniquet under general anesthesia. ONSD and end-tidal CO2 (ETCO2) were measured 5 times: 15 min prior to the anesthesia induction; just prior to the deflation of the tourniquet; and at 5, 10, and 15 min after the deflation. Additionally, age, sex, weight, height, ASA score, and duration of operation and tourniquet usage were recorded. Results: The ONSD value measured 5 min after the deflation was significantly higher than all of the remaining measurements. There was a significant correlation between the ONSD and ETCO2 measurements at 5 and 10 min after deflation (r = 0.61, 95% CI 0.42-0.75, P < 0.0001 and r = 0.30, 95% CI 0.04-0.51, P < 0.05, respectively). Conclusion: The ultrasonographic ONSD measurements, which were obtained using a simple and noninvasive approach, increased significantly following tourniquet deflation, and this increase was correlated with an increase in ETCO2.

🔖

Bu Makaleye Atıf Yap

BEŞİR, A., TUĞCUGİL, E. (2018). Effects of tourniquet usage in lower extremity surgery on optic nerve sheath diameter. Turkish Journal of Medical Sciences, Cilt: 48 - Sayı: 5, 980–984. https://ajindex.com/articles/113475

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Kam PC, Kavanagh R, Yoong FF. The arterial tourniquet: pathophysiological consequences and anaesthetic implications. Anaesthesia 2001; 56: 534-545.
  2. Patel AJ, Choi CS, Giuffrida JG. Changes in end tidal CO2 and arterial blood gas levels after release of tourniquet. Southern Medical Journal 1987; 80: 213-216.
  3. Dinsmore M, Han JS, Fisher JA, Chan VW, Venkatraghavan L. Effects of acute controlled changes in end-tidal carbon dioxide on the diameter of the optic nerve sheath: a transorbital ultrasonographic study in healthy volunteers. Anaesthesia 2017; 72: 618-623.
  4. Kadoi Y, Ide M, Saito S, Shiga T, Ishizaki K, Goto F. Hyperventilation after tourniquet deflation prevents an increase in cerebral blood flow velocity. Can J Anaesth 1999; 46: 259-264.
  5. Hirst RP, Slee TA, Lam AM. Changes in cerebral blood flow velocity after release of intraoperative tourniquets in humans: a transcranial Doppler study. Anesth Analg 1990; 71: 503-510.
  6. Vaquero J, Fontana RJ, Larson AM, Bass NM, Davern TJ, Shakil AO, Han S, Harrison ME, Stravitz TR, Munoz S et al. Complications and use of intracranial pressure monitoring in patients with acute liver failure and severe encephalopathy. Liver Transpl 2005; 11: 1581-1589.
  7. Sahay N, Sharma S, Bhadani UK, Singh A, Sinha C, Sahay A, Ranjan A, Agarwal M. Effect of pneumoperitoneum and patient positioning on intracranial pressures during laparoscopy: a prospective comparative study. J Minim Invasive Gynecol 2018; 25: 147-152.
  8. Killer HE, Laeng HR, Flammer J, Groscurth P. Architecture of arachnoid trabeculae, pillars, and septa in the subarachnoid space of the human optic nerve: anatomy and clinical considerations. Br J Ophthalmol 2003; 87: 777-781.
  9. Geeraerts T, Merceron S, Benhamou D, Vigue B, Duranteau J. Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients. Intensive Care Med 2008; 34: 2062-2067.
  10. Moretti R, Pizzi B. Ultrasonography of the optic nerve in neurocritically ill patients. Acta Anaesthesiol Scand 2011; 55: 644-652.
  11. Arabi Y, Memish ZA, Balkhy HH, Francis C, Ferayan A, Al Shimemeri A, Almuneef MA. Ventriculostomy-associated infections: incidence and risk factors. Am J Infect Control 2005; 33: 137-143.
  12. Dasic D, Hanna SJ, Bojanic S, Kerr RS. External ventricular drain infection: the effect of a strict protocol on infection rates and a review of the literature. Br J Neurosurg 2006; 20: 296-300.
  13. Dubost C, Le Gouez A, Zetlaoui PJ, Benhamou D, Mercier FJ, Geeraerts T. Increase in optic nerve she