Dergiler / Turkish Journal of Medical Sciences / 2019 / Cilt: 49 - Sayı: 6

Abdominal girth has a strong correlation with actual and ultrasound estimated epidural depth

Sayfa
1715–1720
Yayın Tarihi
2019-12-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The Pearson correlation coefficient between ND and ED/PSO was 0.997 and with ED/TM was 0.996 (P

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Background/aim: This study aimed to assess the correlations of actual epidural depth (ND) and ultrasound estimated epidural depth in the paramedian sagittal oblique plane (ED/PSO) and transverse median plane (ED/TM) with the abdominal girth (AG), body mass index (BMI), and weight of patients.
📊
Temel Bulgular & Veri:ED/PSO and ED/TM were assessed with a 2-5 MHz curved array probe at the L3-4 intervertebral space.
💡
Sonuç & Katkı:The Pearson correlation coefficient between ND and ED/PSO was 0.997 and with ED/TM was 0.996 (P
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Abdominal girth · anesthesia · epidural

Abstract

Background/aim: This study aimed to assess the correlations of actual epidural depth (ND) and ultrasound estimated epidural depth in the paramedian sagittal oblique plane (ED/PSO) and transverse median plane (ED/TM) with the abdominal girth (AG), body mass index (BMI), and weight of patients. Materials and methods: One hundred and thirty patients of either sex scheduled for unilateral inguinal hernia repair were enrolled. ED/PSO and ED/TM were assessed with a 2-5 MHz curved array probe at the L3-4 intervertebral space. The epidural needle was marked with a sterile marker upon locating the epidural space. The ND was assessed by measuring the distance from the sterile marker to the tip of the epidural needle with a linear scale. Anthropometric measures of the patients were recorded. Results: ED/PSO was 49.6 ± 7.9 mm, ED/TM was 49.5 ± 7.9 mm, and ND was 50.0 ± 8.0 mm. AG was 99.8 ± 12.9 cm. The Pearson correlation coefficient between ND and ED/PSO was 0.997 and with ED/TM was 0.996 (P

🔖

Bu Makaleye Atıf Yap

CANTÜRK, M., KOCAOĞLU, N., HAKKI, M. (2019). Abdominal girth has a strong correlation with actual and ultrasound estimated epidural depth. Turkish Journal of Medical Sciences, Cilt: 49 - Sayı: 6, 1715–1720. https://ajindex.com/articles/113297

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...