Occupational exposure to electromagnetic fields from dental devices: A descriptive study

Sayfa
403–411
Yayın Tarihi
2023-12-15
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion: The results show that periodic Electromagnetic Field exposure measurements should be conducted to obtain more detailed information about workplace exposures and sources.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: Electromagnetic Field sources, which are widely used as part of the operating mechanism, cause occupational exposure when electricity is generated, distributed, or usage in the everyday environment.
📊
Temel Bulgular & Veri:Method: Measurements were performed while appliances were under working conditions at a 10 cm distance from the device for 6 minutes and for 7 days.
💡
Sonuç & Katkı:Conclusion: The results show that periodic Electromagnetic Field exposure measurements should be conducted to obtain more detailed information about workplace exposures and sources.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Health · electromagnetic field · extremely low-frequency field

Abstract

Objective: Electromagnetic Field sources, which are widely used as part of the operating mechanism, cause occupational exposure when electricity is generated, distributed, or usage in the everyday environment. We aimed to obtain the Extremely Low Frequency-Magnetic Field exposure profile for dental health workers from electrical devices used in dentistry. Method: Measurements were performed while appliances were under working conditions at a 10 cm distance from the device for 6 minutes and for 7 days. The highest measured value in every 10 second was recorded. The mean ± SD of the minimum and maximum Extremely Low Frequency-Magnetic Field for high-speed dental handpiece with LED, low-speed dental handpiece, modeltrimming machine, automatic boil-out unit, steam machine, vacuum device, and polishing machine were recorded in milliGauss. Results: The values obtains from model-trimming machine and polishing machine were remarkable (809.1 ± 37.7 / 975.0 ± 10.2, 649.3 ± 201.3 / 1367.0 ± 32.1, respectively). Conclusion: The results show that periodic Electromagnetic Field exposure measurements should be conducted to obtain more detailed information about workplace exposures and sources.

🔖

Bu Makaleye Atıf Yap

BULUT, A., FIRLARER, A., KARAMÜFTÜOĞLU, N. (2023). Occupational exposure to electromagnetic fields from dental devices: A descriptive study. Turkish Journal of Public Health, Cilt: 21 Sayı: 3, 403–411. https://ajindex.com/articles/1022333

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (9)

  1. Röösli M. Epidemiology of electromagnetic fields. Boca Raton, London, New York: 343, CRC Press. Taylor & Francis Group, LLC, 2014.
  2. Belyaev I, Dean A, Eger H et al. EUROPAEM EMF Guideline 2016 for the prevention, diagnosis and treatment of EMF-related health problems and illnesses. Rev Environ Health 2016;31(3):363–397.
  3. Stam R, Yamaguchi-Sekino S. Occupational exposure to electromagnetic fields from medical sources. Ind Health 2018;56:96–105.
  4. Portier CJ, Wolfe MS. Assessment of health effects from exposure to power-line frequency electric and magnetic fields. Working group report. Research Triangle Park, NC: National Institute of Environmental Health Sciences. Portier CJ, Wolfe MS, editors. 1998 [online]. Available at: http://niremf.ifac.cnr.it/docs/niehs98.pdf. Accessed January, 2023. The International System of Units (SI), Bureau International des Poids et Mesures, 2019 [online]. Available at: https://www.bipm.org. Accessed January, 2023.
  5. Vila J, Bowman J D, Richardson L et al. A Sourcebased measurement database for occupational exposure assessment of electromagnetic fields in the INTEROCC study: A literature review approach. Ann Occup Hyg 2016;60(2):184–204. International Commission on Non-Ionizinig Radiation Protection. Guidelines for limiting exposure to time-varying electric and magnetic 411 EMF exposure from dental devices Turk J Public Health 2023;21(3) fields (1 Hz to 100 kHz). International Commission on Non-Ionizing Radiation Protection. Health Physics 2010;99:818‐836. IARC Working Group on the Evaluation of Carcinogenic Risks to Humans. Non-Ionizing Radiation, Part 2: Radiofrequency Electromagnetic Fields. Lyon (FR): International Agency for Research on Cancer (IARC) May 2011. IARC Monographs on the Evaluation of Carcinogenic Risks to Humans, Vol 102 [online]. Available at: http://monographs.iarc.fr/ENG/Monographs/ vol102/. Accessed December, 2022.
  6. Kim DW, Choi JL, Kwon MK et al. Assessment of daily exposure of endodontic personnel to extremely low frequency magnetic fields. Int Endod J 2012;45(8):744-748.
  7. Huang SM, Lin YW, Sung FC et al. Occupational exposure of dentists to extremely-low-frequency magnetic field. J Occup Health 2011;53(2):130-136.
  8. Newton JT, Thorogood N, Gibbons DE. A study of the career development of male and female dental practitioners. Br Dent J 2000;188(2):90-94.
  9. LeBlanc VR, Urbankova A, Hadavi F et al. A preliminary study in using virtual reality to train dental students. J Dent Educ 2004;68(3):378-383. van Tongeren M, Me